Highly Accurate Recognition of Human Postures and Activities Through Classification With Rejection
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Monitoring of postures and activities is used in many clinical and research applications, some of which may require highly reliable posture and activity recognition with desired accuracy well above 99% mark. This paper suggests a method for performing highly accurate recognition of postures and activities from data collected by a wearable shoe monitor (SmartShoe) through classification with rejection. Signals from pressure and acceleration sensors embedded in SmartShoe are used either as raw sensor data or after feature extraction. The Support vector machine (SVM) and multilayer perceptron (MLP) are used to implement classification with rejection. Unreliable observations are rejected by measuring the distance from the decision boundary and eliminating those observations that reside below rejection threshold. The results show a significant improvement (from 97.3% ± 2.3% to 99.8% ± 0.1%) in the classification accuracy after the rejection, using MLP with raw sensor data and rejecting 31.6% of observations. The results also demonstrate that MLP outperformed the SVM, and the classification accuracy based on raw sensor data was higher than the accuracy based on extracted features. The proposed approach will be especially beneficial in applications where high accuracy of recognition is desired while not all observations need to be assigned a class label.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Rogers, S. J., Hepburn, S., & Wehner, E. (2003) · Journal of Autism and Developmental Disorders · doi:10.1023/b:jadd.0000006000.38991.a7 · Cited by 609
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
A Survey on Activity Detection and Classification Using Wearable Sensors
Cornacchia, M., Ozcan, K., Zheng, Y., & Velipasalar, S. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2628346 · Cited by 424
Panwar, M., Biswas, D., Bajaj, H., Jobges, M., Turk, R., Maharatna, K., & Acharyya, A. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2899927 · Cited by 158
Machine learning with a reject option: A survey
Hendrickx, K., Perini, L., Van der Plas, D., Meert, W., & Davis, J. (2024) · Machine Learning · doi:10.1007/s10994-024-06534-x · Cited by 134
Metadata
- Authors
- Tang, W., & Sazonov, E. S.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2014-01
- Volume
- 18
- Issue
- 1
- Pages
- 309-315
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1973555673
- Cited by
- 71
- References
- 3
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Accurate Recognition of Human Postures and Activities Through Classification With Rejection. https://app.cochat.ai/papers/10.1109/jbhi.2013.2287400
- The paper
- Tang, W., & Sazonov, E. S. (2014). Highly Accurate Recognition of Human Postures and Activities Through Classification With Rejection. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2013.2287400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.