The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
DREAM: Diabetic Retinopathy Analysis Using Machine Learning
Abstract
This paper presents a computer-aided screening system (DREAM) that analyzes fundus images with varying illumination and fields of view, and generates a severity grade for diabetic retinopathy (DR) using machine learning. Classifiers such as the Gaussian Mixture model (GMM), k-nearest neighbor (kNN), support vector machine (SVM), and AdaBoost are analyzed for classifying retinopathy lesions from nonlesions. GMM and kNN classifiers are found to be the best classifiers for bright and red lesion classification, respectively. A main contribution of this paper is the reduction in the number of features used for lesion classification by feature ranking using Adaboost where 30 top features are selected out of 78. A novel two-step hierarchical classification approach is proposed where the nonlesions or false positives are rejected in the first step. In the second step, the bright lesions are classified as hard exudates and cotton wool spots, and the red lesions are classified as hemorrhages and micro-aneurysms. This lesion classification problem deals with unbalanced datasets and SVM or combination classifiers derived from SVM using the Dempster-Shafer theory are found to incur more classification error than the GMM and kNN classifiers due to the data imbalance. The DR severity grading system is tested on 1200 images from the publicly available MESSIDOR dataset. The DREAM system achieves 100% sensitivity, 53.16% specificity, and 0.904 AUC, compared to the best reported 96% sensitivity, 51% specificity, and 0.875 AUC, for classifying images as with or without DR. The feature reduction further reduces the average computation time for DR severity per image from 59.54 to 3.46 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Evidence
Shafer, G. (1976) · Princeton University Press eBooks · doi:10.1515/9780691214696 · Cited by 9,083
An Evaluation of Statistical Approaches to Text Categorization
Yang, Y. (1999) · Information Retrieval · doi:10.1023/a:1009982220290 · Cited by 1,943
Cost-sensitive boosting for classification of imbalanced data
Sun, Y., Kamel, M. S., Wong, A. K. C., & Wang, Y. (2007) · Pattern Recognition · doi:10.1016/j.patcog.2007.04.009 · Cited by 1,423
the DIARETDB1 diabetic retinopathy database and evaluation protocol
Kauppi, T., Kalesnykiene, V., Kamarainen, J.-K., Lensu, L., Sorri, I., Raninen, A., Voutilainen, R., Uusitalo, H., Kalviainen, H., & Pietila, J. (2007) · Procedings of the British Machine Vision Conference 2007 · doi:10.5244/c.21.15 · Cited by 854
Walter, T., Klein, J., Massin, P., & Erginay, A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806290 · Cited by 825
Automatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Sopharak, A., Uyyanonvara, B., Barman, S., & Williamson, T. H. (2008) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2008.08.009 · Cited by 405
EyePACS: An Adaptable Telemedicine System for Diabetic Retinopathy Screening
Cuadros, J., & Bresnick, G. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300315 · Cited by 390 · cited 1×
“Telemedicine, with distributed remote retinal fundus imaging and grading at either local primary care offices or centralized grading remotely by eye care specialists, has increased access to screening and follow-up necessary treatment [4].”
BackgroundOptimal Wavelet Transform for the Detection of Microaneurysms in Retina Photographs
Quellec, G., Lamard, M., Josselin, P. M., Cazuguel, G., Cochener, B., & Roux, C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.920619 · Cited by 343
An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading
Antal, B., & Hajdu, A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2193126 · Cited by 335
Cited by
Prediction of cardiovascular risk factors from retinal fundus photographs via deep learning
Poplin, R., Varadarajan, A. V., Blumer, K., Liu, Y., McConnell, M. V., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0195-0 · Cited by 1,865
Machine learning and data mining methods in diabetes research
Kavakiotis, I., Tsave, O., Salifoglou, A., Maglaveras, N., Vlahavas, I., & Chouvarda, I. (2017) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2016.12.005 · Cited by 1,445
Automated Identification of Diabetic Retinopathy Using Deep Learning
Gargeya, R., & Leng, T. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.02.008 · Cited by 1,362
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Deep learning for diabetic retinopathy detection and classification based on fundus images: A review
Tsiknakis, N., Theodoropoulos, D., Manikis, G., Ktistakis, E., Boutsora, O., Berto, A., Scarpa, F., Scarpa, A., Fotiadis, D. I., & Marias, K. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104599 · Cited by 328
Metadata
- Authors
- Roychowdhury, S., Koozekanani, D. D., & Parhi, K. K.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2014-09
- Volume
- 18
- Issue
- 5
- Pages
- 1717-1728
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1982168774
- Cited by
- 413
- References
- 24
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DREAM: Diabetic Retinopathy Analysis Using Machine Learning. https://app.cochat.ai/papers/10.1109/jbhi.2013.2294635
- The paper
- Roychowdhury, S., Koozekanani, D. D., & Parhi, K. K. (2014). DREAM: Diabetic Retinopathy Analysis Using Machine Learning. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2013.2294635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.