The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fall Detection in Homes of Older Adults Using the Microsoft Kinect
Abstract
A method for detecting falls in the homes of older adults using the Microsoft Kinect and a two-stage fall detection system is presented. The first stage of the detection system characterizes a person's vertical state in individual depth image frames, and then segments on ground events from the vertical state time series obtained by tracking the person over time. The second stage uses an ensemble of decision trees to compute a confidence that a fall preceded on a ground event. Evaluation was conducted in the actual homes of older adults, using a combined nine years of continuous data collected in 13 apartments. The dataset includes 454 falls, 445 falls performed by trained stunt actors and nine naturally occurring resident falls. The extensive data collection allows for characterization of system performance under real-world conditions to a degree that has not been shown in other studies. Cross validation results are included for standing, sitting, and lying down positions, near (within 4 m) versus far fall locations, and occluded versus not occluded fallers. The method is compared against five state-of-the-art fall detection algorithms and significantly better results are achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anthropometric Reference Data for Children and Adults: United States, 2003-2006: (623932009-001)
McDowell, M. A., Fryar, C. D., Ogden, C. L., & Flegal, K. M. (2008) · PsycEXTRA Dataset · doi:10.1037/e623932009-001 · Cited by 1,378
Portable preimpact fall detector with inertial sensors
Wu, G., & Xue, S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916282 · Cited by 227
Cited by
A survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
Elderly Fall Detection Systems: A Literature Survey
Wang, X., Ellul, J., & Azzopardi, G. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.00071 · Cited by 380
Abnormal behavior recognition for intelligent video surveillance systems: A review
Ben Mabrouk, A., & Zagrouba, E. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.09.029 · Cited by 361
Habibzadeh, H., Nussbaum, B. H., Anjomshoa, F., Kantarci, B., & Soyata, T. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101660 · Cited by 303
Illuminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274
Metadata
- Authors
- Stone, E. E., & Skubic, M.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2015-01
- Volume
- 19
- Issue
- 1
- Pages
- 290-301
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2100716893
- Cited by
- 528
- References
- 2
- FWCI
- 50.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fall Detection in Homes of Older Adults Using the Microsoft Kinect. https://app.cochat.ai/papers/10.1109/jbhi.2014.2312180
- The paper
- Stone, E. E., & Skubic, M. (2015). Fall Detection in Homes of Older Adults Using the Microsoft Kinect. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2014.2312180
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.