Cardiorespiratory Sleep Stage Detection Using Conditional Random Fields
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper explores the probabilistic properties of sleep stage sequences and transitions to improve the performance of sleep stage detection using cardiorespiratory features. A new classifier, based on conditional random fields, is used in different sleep stage detection tasks (N3, NREM, REM, and wake) in night-time recordings of electrocardiogram and respiratory inductance plethysmography of healthy subjects. Using a dataset of 342 polysomnographic recordings of healthy subjects, among which 135 with regular sleep architecture, it outperforms hidden Markov models and Bayesian linear discriminants in all tasks, achieving an average accuracy of 87.38% and kappa of 0.41 (87.27% and 0.49 for regular subjects) for N3 detection, 78.71% and 0.55 (80.34% and 0.56 for regular subjects) for NREM detection, 88.49% and 0.51 (87.35% and 0.57 for regular subjects) for REM, and 85.69% and 0.51 (90.42% and 0.52 for regular subjects) for wake. In comparison with the state of the art, and having been tested on a much larger dataset, the classifier was found to outperform most of the work reported in the literature for some of the tasks, in particular for subjects with regular sleep architecture. It achieves a comparable accuracy for N3, higher accuracy and kappa for REM, and higher accuracy and comparable kappa for NREM than the best performing classifiers described in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880 · cited 2×
“1–3 Respiratory frequency calculated in time and frequency domain and its spectral power [6], [25] 4–7 PSD VLF, LF, and HF power and LF-to-HF ratio [25] 8–10 SD of respiratory frequency over 150, 210, and 270 s [6] 11–13 Mean and SD of breath-by-breath correlations, SD of breath lengths [25] 14-15 Sample entropy and v…”
BackgroundFactor graphs and the sum-product algorithm
Kschischang, F. R., Frey, B. J., & Loeliger, H.-A. (2001) · IEEE Transactions on Information Theory · doi:10.1109/18.910572 · Cited by 6,486 · cited 1×
“Parameter learning and inference is usually performed by means of factor graphs [46], a type of model which describes the probability distribution of”
MethodOhayon, M. M., Carskadon, M. A., Guilleminault, C., & Vitiello, M. V. (2004) · Sleep · doi:10.1093/sleep/27.7.1255 · Cited by 3,349
Multiscale Entropy Analysis of Complex Physiologic Time Series
Costa, M., Goldberger, A. L., & Peng, C.-K. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.068102 · Cited by 3,207
THE FIRST NIGHT EFFECT: AN EEG STUDYOF SLEEP
Agnew, H. W., Webb, W. B., & Williams, R. L. (1966) · Psychophysiology · doi:10.1111/j.1469-8986.1966.tb02650.x · Cited by 1,147 · cited 1×
“This effect, also called “first night effect”[18] actually often lasts more than the first night and is variable from subject to subject.”
Background
Cited by
An Attention-Based Deep Learning Approach for Sleep Stage Classification With Single-Channel EEG
Eldele, E., Chen, Z., Liu, C., Wu, M., Kwoh, C.-K., Li, X., & Guan, C. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3076234 · Cited by 693
Sleep stage classification from heart-rate variability using long short-term memory neural networks
Radha, M., Fonseca, P., Moreau, A., Ross, M., Cerny, A., Anderer, P., Long, X., & Aarts, R. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-49703-y · Cited by 186
“A large part of the feature set from these IBI sequences has been described in earlier work where a set of cardiac and respiratory features were evaluated 7 , however only the cardiac subset of the features is used in this work as no respiratory signal was included.”
MethodSelf-citationPapini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90
Self-citationTowards robust and label-efficient time series representation learning
Emadeldeen, A. I. A. E. (2023) · doi:10.32657/10356/170673 · Cited by 1
Metadata
- Authors
- Fonseca, P., den Teuling, N., Long, X., & Aarts, R. M.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2017-07
- Volume
- 21
- Issue
- 4
- Pages
- 956-966
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2320406861
- Cited by
- 74
- References
- 5
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiorespiratory Sleep Stage Detection Using Conditional Random Fields. https://app.cochat.ai/papers/10.1109/jbhi.2016.2550104
- The paper
- Fonseca, P., den Teuling, N., Long, X., & Aarts, R. M. (2017). Cardiorespiratory Sleep Stage Detection Using Conditional Random Fields. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2016.2550104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.