CoChat

Epileptic Seizure Classification of EEGs Using Time–Frequency Analysis Based Multiscale Radial Basis Functions

Li, Yang, Wang, Xu-Dong, Luo, Mei-Lin, Li, Ke, Yang, Xiao-Feng, Guo, Qi · 2018 · IEEE Journal of Biomedical and Health Informatics
Cited by 160

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

The automatic detection of epileptic seizures from electroencephalography (EEG) signals is crucial for the localization and classification of epileptic seizure activity. However, seizure processes are typically dynamic and nonstationary, and thus, distinguishing rhythmic discharges from nonstationary processes is one of the challenging problems. In this paper, an adaptive and localized time-frequency representation in EEG signals is proposed by means of multiscale radial basis functions (MRBF) and a modified particle swarm optimization (MPSO) to improve both time and frequency resolution simultaneously, which is a novel MRBF-MPSO framework of the time-frequency feature extraction for epileptic EEG signals. The dimensionality of extracted features can be greatly reduced by the principle component analysis algorithm before the most discriminative features selected are fed into a support vector machine (SVM) classifier with the radial basis function (RBF) in order to separate epileptic seizure from seizure-free EEG signals. The classification performance of the proposed method has been evaluated by using several state-of-art feature extraction algorithms and other five different classifiers like linear discriminant analysis, and logistic regression. The experimental results indicate that the proposed MRBF-MPSO-SVM classification method outperforms competing techniques in terms of classification accuracy, and shows the effectiveness of the proposed method for classification of seizure epochs and seizure-free epochs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2017.2654479

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Cited by

See all 160

Metadata

Authors
Li, Y., Wang, X.-D., Luo, M.-L., Li, K., Yang, X.-F., & Guo, Q.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2018-03
Volume
22
Issue
2
Pages
386-397
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2592790850
Cited by
160
References
46
FWCI
8.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Epileptic Seizure Classification of EEGs Using Time–Frequency Analysis Based Multiscale Radial Basis Functions. https://app.cochat.ai/papers/10.1109/jbhi.2017.2654479
The paper
Li, Y., Wang, X.-D., Luo, M.-L., Li, K., Yang, X.-F., & Guo, Q. (2018). Epileptic Seizure Classification of EEGs Using Time–Frequency Analysis Based Multiscale Radial Basis Functions. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2017.2654479

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.