A Novel Authentication and Key Agreement Scheme for Implantable Medical Devices Deployment
The DOI matches its Crossref record.
Abstract
Implantable medical devices (IMDs) are man-made devices, which can be implanted in the human body to improve the functioning of various organs. The IMDs monitor and treat physiological condition of the human being (for example, monitoring of blood glucose level by insulin pump). The advancement of information and communication technology enhances the communication capabilities of IMDs. In healthcare applications, after mutual authentication, a user (for example, doctor) can access the health data from the IMDs implanted in a patient's body. However, in this kind of communication environment, there are always security and privacy issues, such as leakage of health data and malfunctioning of IMDs by an unauthorized access. To mitigate these issues, in this paper, we propose a new secure remote user authentication scheme for IMDs communication environment to overcome security and privacy issues in existing schemes. We provide the formal security verification using the widely accepted Automated Validation of Internet Security Protocols and Applications tool. We also provide the informal security analysis of the proposed scheme. The formal security verification and informal security analysis prove that the proposed scheme is secure against known attacks. The practical demonstration of the proposed scheme is performed using the broadly accepted NS2 simulation tool. The computation and communication costs of the proposed scheme are also comparable with the existing schemes. Moreover, the scheme provides additional functionality features, such as anonymity, untraceability, and dynamic implantable medical device addition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Impact of Trust and Privacy Concerns on Technology Acceptance in Healthcare: An Indian Perspective
Dhagarra, D., Goswami, M., & Kumar, G. (2020) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2020.104164 · Cited by 436
Design of Secure User Authenticated Key Management Protocol for Generic IoT Networks
Wazid, M., Das, A. K., Odelu, V., Kumar, N., Conti, M., & Jo, M. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2780232 · Cited by 400
Self-citationYaqoob, T., Abbas, H., & Atiquzzaman, M. (2019) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2914094 · Cited by 236
“The research [188] proposed an authentication scheme through which controller node and user mutually authenticate one another and create a session key for further communication by using ECC cryptogram.”
MethodDesign of secure key management and user authentication scheme for fog computing services
Wazid, M., Das, A. K., Kumar, N., & Vasilakos, A. V. (2019) · Future Generation Computer Systems · doi:10.1016/j.future.2018.09.017 · Cited by 232
Self-citationGarg, N., Wazid, M., Das, A. K., Singh, D. P., Rodrigues, J. J. P. C., & Park, Y. (2020) · IEEE Access · doi:10.1109/access.2020.2995917 · Cited by 211
Self-citationDesign of Secure and Lightweight Authentication Protocol for Wearable Devices Environment
Das, A. K., Wazid, M., Kumar, N., Khan, M. K., Choo, K.-K. R., & Park, Y. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2753464 · Cited by 207
“protocols [32], [46], [49], [50], [51], [52], [53], [54].”
Self-citationPundir, S., Wazid, M., Singh, D. P., Das, A. K., Rodrigues, J. J. P. C., & Park, Y. (2020) · IEEE Access · doi:10.1109/access.2019.2962829 · Cited by 202
Self-citationIoMT malware detection approaches: analysis and research challenges
Wazid, M., Das, A. K., Rodrigues, J. J. P. C., Shetty, S., & Park, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2960412 · Cited by 200
Self-citationSecuring electronics healthcare records in Healthcare 4.0 : A biometric-based approach
Hathaliya, J. J., Tanwar, S., Tyagi, S., & Kumar, N. (2019) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2019.04.017 · Cited by 194
Self-citationAghili, S. F., Mala, H., Shojafar, M., & Peris-Lopez, P. (2019) · Future Generation Computer Systems · doi:10.1016/j.future.2019.02.020 · Cited by 186
“, pacemaker or smart ECG T-shirt [18]) that collect patient information [19, 20].”
BackgroundRasool, R. U., Ahmad, H. F., Rafique, W., Qayyum, A., & Qadir, J. (2022) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2022.103332 · Cited by 177
Authentication in cloud-driven IoT-based big data environment: Survey and outlook
Wazid, M., Das, A. K., Hussain, R., Succi, G., & Rodrigues, J. J. P. C. (2019) · Journal of Systems Architecture · doi:10.1016/j.sysarc.2018.12.005 · Cited by 169
Self-citationLITNET-2020: An Annotated Real-World Network Flow Dataset for Network Intrusion Detection
Damasevicius, R., Venckauskas, A., Grigaliunas, S., Toldinas, J., Morkevicius, N., Aleliunas, T., & Smuikys, P. (2020) · Electronics · doi:10.3390/electronics9050800 · Cited by 132
“Therefore, hereinafter, for analysis, we use only datasets that have been widely adopted and used by the research community [58,67–69].”
Method
Metadata
- Authors
- Wazid, M., Das, A. K., Kumar, N., Conti, M., & Vasilakos, A. V.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2018-07
- Volume
- 22
- Issue
- 4
- Pages
- 1299-1309
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2729021829
- Cited by
- 141
- References
- 0
- FWCI
- 13.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.