The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Variational Mode Extraction: A New Efficient Method to Derive Respiratory Signals from ECG
Abstract
ECG-derived respiratory (EDR) signal is an effective and inexpensive method to monitor the respiration. Previous studies have shown that the empirical mode decomposition (EMD) techniques can satisfactorily extract the EDR signal, however, their performances are degraded at the presence of noise. On the other hand, variational mode decomposition (VMD) performs good robustness against noise. In applications such as EDR extraction, where a specific mode is in interest, VMD imposes unnecessary computational cost. In this paper, we consider the extraction of EDR as a problem of obtaining a specific mode of a signal and suggest a new method named as variational mode extraction (VME). The method is established on the similar basis as VMD, with a new criterion: The residual signal after extracting the specific mode should have no or less energy at the center frequency of the mode. In this regard, VME is capable of solving the EDR problem by considering the EDR signal as a mode with approximate center frequency of zero. For verification, the respiratory rate signal is detected from EDR signal extracted by VME and compared it with those obtained by VMD, EMD-based methods, and bandpass filtering. The results confirm that the new method can extract the EDR signal with a better accuracy, while performing much lower computational cost and higher convergence rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gilles, J. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2265222 · Cited by 2,210
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 1×
“The ECG signal can actually be corrupted by several sources of noise such as power line interference, electrode contact noise, motion artifact, muscle contraction (EMG), electrosurgical noise, and the instrumentation noise generated by electronic devices used in signal processing [25].”
Background
Cited by
Successive variational mode decomposition
Nazari, M., & Sakhaei, S. M. (2020) · Signal Processing · doi:10.1016/j.sigpro.2020.107610 · Cited by 500
Self-citation
Metadata
- Authors
- Nazari, M., & Sakhaei, S. M.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2018-07
- Volume
- 22
- Issue
- 4
- Pages
- 1059-1067
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2741034219
- Cited by
- 214
- References
- 3
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variational Mode Extraction: A New Efficient Method to Derive Respiratory Signals from ECG. https://app.cochat.ai/papers/10.1109/jbhi.2017.2734074
- The paper
- Nazari, M., & Sakhaei, S. M. (2018). Variational Mode Extraction: A New Efficient Method to Derive Respiratory Signals from ECG. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2017.2734074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.