CoChat

The CirCor DigiScope Dataset: From Murmur Detection to Murmur Classification

Open access
Oliveira, Jorge, Renna, Francesco, Costa, Paulo Dias, Nogueira, Marcelo, Oliveira, Cristina, Ferreira, Carlos, Jorge, Alipio, Mattos, Sandra, Hatem, Thamine, Tavares, Thiago, Elola, Andoni, Rad, Ali Bahrami, Sameni, Reza, Clifford, Gari D., Coimbra, Miguel T. · 2022 · IEEE Journal of Biomedical and Health Informatics
Cited by 212

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Cardiac auscultation is one of the most cost-effective techniques used to detect and identify many heart conditions. Computer-assisted decision systems based on auscultation can support physicians in their decisions. Unfortunately, the application of such systems in clinical trials is still minimal since most of them only aim to detect the presence of extra or abnormal waves in the phonocardiogram signal, i.e., only a binary ground truth variable (normal vs abnormal) is provided. This is mainly due to the lack of large publicly available datasets, where a more detailed description of such abnormal waves (e.g., cardiac murmurs) exists. To pave the way to more effective research on healthcare recommendation systems based on auscultation, our team has prepared the currently largest pediatric heart sound dataset. A total of 5282 recordings have been collected from the four main auscultation locations of 1568 patients, in the process, 215780 heart sounds have been manually annotated. Furthermore, and for the first time, each cardiac murmur has been manually annotated by an expert annotator according to its timing, shape, pitch, grading, and quality. In addition, the auscultation locations where the murmur is present were identified as well as the auscultation location where the murmur is detected more intensively. Such detailed description for a relatively large number of heart sounds may pave the way for new machine learning algorithms with a real-world application for the detection and analysis of murmur waves for diagnostic purposes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2021.3137048

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 212

Metadata

Authors
Oliveira, J., Renna, F., Costa, P. D., Nogueira, M., Oliveira, C., Ferreira, C., Jorge, A., Mattos, S., Hatem, T., Tavares, T., Elola, A., Rad, A. B., Sameni, R., Clifford, G. D., & Coimbra, M. T.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2022-06
Volume
26
Issue
6
Pages
2524-2535
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W3191193899
Cited by
212
References
3
FWCI
17.87
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The CirCor DigiScope Dataset: From Murmur Detection to Murmur Classification. https://app.cochat.ai/papers/10.1109/jbhi.2021.3137048
The paper
Oliveira, J., Renna, F., Costa, P. D., Nogueira, M., Oliveira, C., Ferreira, C., Jorge, A., Mattos, S., Hatem, T., Tavares, T., Elola, A., Rad, A. B., Sameni, R., Clifford, G. D., & Coimbra, M. T. (2022). The CirCor DigiScope Dataset: From Murmur Detection to Murmur Classification. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2021.3137048

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.