Internal Power Flow of a Modular Multilevel Converter With Distributed Energy Resources
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper examines the internal power flow mechanisms that exist within a generalized modular multilevel converter (MMC) and examines alternatives for integration of distributed energy resources (DERs) within the MMC structure. Each phase leg of the MMC consists of two series connected strings of submodules, where each string of submodules is referred to as a phase arm. Based on analytically developed inter-arm power flow relations, a control methodology is proposed, which provides fully independent control of each arm's real power flow, facilitating extreme levels of inter-arm power transfer. This eliminates the need for uniform integration of DER units across all submodules of the MMC. Among others, viable operating configurations are shown to include DERs only integrated in the upper (or lower) phase arms and DERs integrated only in the upper and lower phase arms of a single phase leg. Power balance is maintained internal to the MMC via dc and ac currents circulating within the converter without distorting input dc or output ac currents. To maximize conversion efficiency, a mechanism for minimizing the necessary circulating ac currents under any inter-arm power flow condition is also identified. Comprehensive simulation results validate both the developed model and controls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Marquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
Cited by
Xavier, L. S., Amorim, W. C. S., Cupertino, A. F., Mendes, V. F., do Boaventura, W. C., & Pereira, H. A. (2019) · BMC Energy · doi:10.1186/s42500-019-0006-5 · Cited by 61
Capacitor Voltage Estimation Scheme With Reduced Number of Sensors for Modular Multilevel Converters
Abushafa, O. S. M., Gadoue, S. M., Dahidah, M. S. A., Atkinson, D. J., & Missailidis, P. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2797245 · Cited by 53
Fehr, H., & Gensior, A. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2805103 · Cited by 17
Metadata
- Authors
- Soong, T., & Lehn, P. W.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2014-12
- Volume
- 2
- Issue
- 4
- Pages
- 1127-1138
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W1975172272
- Cited by
- 123
- References
- 2
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Internal Power Flow of a Modular Multilevel Converter With Distributed Energy Resources. https://app.cochat.ai/papers/10.1109/jestpe.2014.2342656
- The paper
- Soong, T., & Lehn, P. W. (2014). Internal Power Flow of a Modular Multilevel Converter With Distributed Energy Resources. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2014.2342656
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.