Frequency Support Functions in Large PV Power Plants With Active Power Reserves
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The total installed capacity of photovoltaic (PV) power, within each year, constantly pressures transmission system operators to continuously upgrade their network codes (NCs) moving their focus to grid stabilization features. The NCs started to demand large-scale PV power plants (LPVPPs) to synthetically inherit frequency support functions from the conventional generation-frequency sensitive mode (FSM) and encourage the use of inertial response (IR) along with a minimum supply of active power reserves (APRs). This paper investigates the impact of LPVPPs supplying mandatory FSM enhanced with high-sensitivity IR over the frequency quality parameters. Moreover, the paper performs a time-domain evaluation combined with a statistical analysis of the generated synthetic frequency. The main purpose is to demonstrate the short-term and midterm benefits brought by the added ancillary services and to prove their need with increased levels of PV penetration. This paper realizes a complete representation of a power system having modeled the generic IEEE 12 bus system evaluated over a real-time digital simulator platform. The power system model is enhanced with an automatic generation control system and subject to a realistic Danish winter load profile to create the synthetic frequency of the grid. LPVPPs with APRs and frequency support functions share part of the control responsibilities and show their contributions for short-term and midterm frequency stability once the penetration level reaches higher levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719 · cited 1×
“3) Small Power System Issues: high slopes in irradiance can cause generator tripping in the system [8]–[11].”
BackgroundGrid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344 · cited 2×
“instabilities toward a more harmonized grid operation in which LPVPPs have more responsibilities [3].”
BackgroundMethodSelf-citationPower system dynamics : stability and control
Machowski, J., Bialek, J. W., & Bumby, J. R. (2008) · Durham Research Online (Durham University) · Cited by 2,348
Instantaneous Power Theory and Applications to Power Conditioning
Akagi, H., Watanabe, E. H., & Aredes, M. (2007) · Wiley eBooks · doi:10.1002/0470118938 · Cited by 2,234
Robust Power System Frequency Control
Bevrani, H. (2009) · Springer eBooks · doi:10.1007/978-0-387-84878-5 · Cited by 1,164 · cited 2×
“AGC changes for the IEEE 12 bus system [22], [23].”
MethodA Survey of Frequency and Voltage Control Ancillary Services—Part I: Technical Features
Rebours, Y. G., Kirschen, D. S., Trotignon, M., & Rossignol, S. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.888963 · Cited by 788 · cited 1×
“complete shutdown, a situation present in large wind power plants during the delivery of inertial power [4]–[7].”
BackgroundDelille, G., Francois, B., & Malarange, G. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2205025 · Cited by 776
Power System Control and Stability
Anderson, P. M., Fouad, A. A., & Happ, H. H. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310158 · Cited by 699
Smart Grid: Fundamentals of Design and Analysis
Momoh, J. (2012) · Wiley eBooks · doi:10.1002/9781118156117 · Cited by 289 · cited 1×
“complete shutdown, a situation present in large wind power plants during the delivery of inertial power [4]–[7].”
Background
Cited by
Grid-Forming Inverters: A Critical Asset for the Power Grid
Lasseter, R. H., Chen, Z., & Pattabiraman, D. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959271 · Cited by 864
A review of key power system stability challenges for large-scale PV integration
Shah, R., Mithulananthan, N., Bansal, R. C., & Ramachandaramurthy, V. K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.09.027 · Cited by 501
High-Level Penetration of Renewable Energy Sources Into Grid Utility: Challenges and Solutions
Alam, M. S., Al-Ismail, F. S., Salem, A., & Abido, M. A. (2020) · IEEE Access · doi:10.1109/access.2020.3031481 · Cited by 431
Power Electronics Technology for Large-Scale Renewable Energy Generation
Blaabjerg, F., Yang, Y., Kim, K. A., & Rodriguez, J. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3253165 · Cited by 330
Rapid Active Power Control of Photovoltaic Systems for Grid Frequency Support
Hoke, A. F., Shirazi, M., Chakraborty, S., Muljadi, E., & Maksimovic, D. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2669299 · Cited by 254
A Sensorless Power Reserve Control Strategy for Two-Stage Grid-Connected PV Systems
Sangwongwanich, A., Yang, Y., & Blaabjerg, F. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2648890 · Cited by 204
“, battery) are normally employed to realize the power reserve in PV systems [11]–[16].”
BackgroundGrid-Connected Energy Storage Systems: State-of-the-Art and Emerging Technologies
Farivar, G. G., Manalastas, W., Tafti, H. D., Ceballos, S., Sanchez-Ruiz, A., Lovell, E. C., Konstantinou, G., Townsend, C. D., Srinivasan, M., & Pou, J. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3183289 · Cited by 203
“Such functionalities of PV systems are demonstrated in [150]–[153].”
BackgroundPower Reserves Control for PV Systems With Real-Time MPP Estimation via Curve Fitting
Batzelis, E. I., Kampitsis, G. E., & Papathanassiou, S. A. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2674693 · Cited by 191
“References [3]–[7], [10], [12] implement techniques that follow external power commands, in addition to frequency response, employing different MPP estimation methods.”
MethodPower control flexibilities for grid‐connected multi‐functional photovoltaic inverters
Yang, Y., Blaabjerg, F., Wang, H., & Simões, M. G. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0133 · Cited by 182
“-Watt function) [7], [17]–[19], and reliability-oriented thermal management/control [20]–[23].”
BackgroundDelta Power Control Strategy for Multistring Grid-Connected PV Inverters
Sangwongwanich, A., Yang, Y., Blaabjerg, F., & Sera, D. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2681044 · Cited by 175
“One method to estimate the available PV power is to use the irradiance measurement together with the PV array characteristic model in order to estimate the PV power at the MPP, as implemented in [7], [9].”
BackgroundMethodSelf-citationHaghighat, M., Niroomand, M., Dehghani Tafti, H., D. Townsend, C., & Fernando, T. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2022.000845 · Cited by 30
Metadata
- Authors
- Craciun, B.-I., Kerekes, T., Sera, D., & Teodorescu, R.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2014-12
- Volume
- 2
- Issue
- 4
- Pages
- 849-858
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2078924865
- Cited by
- 192
- References
- 11
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.