Extended Switched-Boost DC-DC Converters Adopting Switched-Capacitor/Switched-Inductor Cells for High Step-up Conversion
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper proposes a family of switched-boost dc-dc converters for the high stepup voltage conversion applications, such as renewable energy power generation, uninterruptible power supply, and automobile high-intensity discharge headlamps. Compared with other dc-dc converters, the proposed switched-boost converter, which combines the traditional switched-boost network with the switched-capacitor/switched-inductor cells, has the following features: higher output voltage gain, a fewer passive components such as inductors and capacitors, and lower voltage stress across the output diode and power switches. Another advantage of the proposed topology is its expandability. If a higher voltage conversion ratio is required, additional cells can be easily cascaded by adding one inductor and three diodes. The structure, operating principle analysis, parameter design, and comparison with other dc-dc converters are also analyzed. Finally, both simulations and experimental results are presented to verify the effectiveness of the proposed converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peng, F. Z. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808920 · Cited by 3,228
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423 · cited 2×
“Among this, the fuel cells and photovoltaic arrays are the main utilization method of the new energy resources, which have got rapid development [3], [4].”
BackgroundAxelrod, B., Berkovich, Y., & Ioinovici, A. (2008) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.916403 · Cited by 1,379 · cited 2×
“13 and compared with the existing SC boost (SC-Boost) converter with two SC cells in [21], SL boost (SL-Boost) converter with three SL cells in [23], 3-Z network boost (3-Z-Boost) converter in [26], the symmetrical hybrid SL (SH-SLC) converter in [24], and the”
BackgroundCascaded DC–DC Converter Connection of Photovoltaic Modules
Walker, G. R., & Sernia, P. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830090 · Cited by 1,032
Nehrir, M. H., Wang, C., Strunz, K., Aki, H., Ramakumar, R., Bing, J., Miao, Z., & Salameh, Z. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2157540 · Cited by 928
Transformerless DC–DC Converters With High Step-Up Voltage Gain
Yang, L.-S., Liang, T.-J., & Chen, J.-F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2022512 · Cited by 808 · cited 1×
“And a transformerless dc–dc converter with high voltage gain has been presented in [19], which can be used to reduce the voltage and current stress, but the voltage gain is usually lower than five.”
Voltage Multiplier Cells Applied to Non-Isolated DC–DC Converters
Prudente, M., Pfitscher, L. L., Emmendoerfer, G., Romaneli, E. F., & Gules, R. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915762 · Cited by 750 · cited 1×
“In [17], the nonisolated high stepup dc–dc converters with single-phase and multiphase voltage multiplier cells have been proposed, which have a low switch voltage stress and low commutation losses.”
BackgroundIntegration of Alternative Sources of Energy
(2005) · Integration of Alternative Sources of Energy · doi:10.1002/0471755621.ch12 · Cited by 675
A DC–DC multilevel boost converter
Rosas-Caro, J. C., Ramirez, J. M., Peng, F. Z., & Valderrabano, A. (2010) · IET Power Electronics · doi:10.1049/iet-pel.2008.0253 · Cited by 522 · cited 1×
“While for many other industrial applications, such as electrical vehicle auxiliary power supplies, TV-CRTs, medical X-ray equipment systems, and automobile high-intensity discharge headlamps, the dc/dc converter with high voltage conversion ratio is also required [6], [7].”
BackgroundHybrid Switched-Inductor Converters for High Step-Up Conversion
Tang, Y., Fu, D., Wang, T., & Xu, Z. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2364797 · Cited by 451 · cited 1×
“13 and compared with the existing SC boost (SC-Boost) converter with two SC cells in [21], SL boost (SL-Boost) converter with three SL cells in [23], 3-Z network boost (3-Z-Boost) converter in [26], the symmetrical hybrid SL (SH-SLC) converter in [24], and the”
Cited by
Zhang, Y., Liu, Q., Gao, Y., Li, J., & Sumner, M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2850020 · Cited by 178
“ferent paths during the charging and the discharging processes, so as to achieve high voltage gain [15]–[18].”
BackgroundWu, X., Wang, J., Zhang, Y., Du, J., Liu, Z., & Chen, Y. (2021) · Automotive Innovation · doi:10.1007/s42154-021-00163-z · Cited by 42
Metadata
- Authors
- Zhu, X., Zhang, B., Li, Z., Li, H., & Ran, L.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2017-09
- Volume
- 5
- Issue
- 3
- Pages
- 1020-1030
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2564302816
- Cited by
- 179
- References
- 24
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.