Hybrid Energy Storage System With Active Filter Function for Shipboard MVDC System Applications Based on Isolated Modular Multilevel DC/DC Converter
The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
Abstract
This paper proposes an isolated modular multilevel dc/dc converter (iM2DC)-based hybrid energy storage system (ESS) for shipboard MVDC grid application. The cell capacitors of the iM2DC are applied to implement the dc active power filter capability, which improves the MVDC bus power quality without auxiliary devices or sacrificing the battery lifetime. In addition, the proposed ESS achieves superior fault response with fault current limiting function, which benefits the fault localization and fast recovery. The operation principle of the proposed system is introduced first and the converter equivalent averaged model is derived. Then the multifunctional control method is presented, including the virtual-impedance-based ripple distribution strategy. Both offline simulation and controller hardware-in-the-loop test results are provided to validate the control strategy as well as the ESS performance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889939 · Cited by 669 · cited 1×
“High power bidirectional dc/dc converters have been investigated in MV power conversion system applications [8] and can be applied to interface battery storage.”
BackgroundYang, Y., Li, H., Aichhorn, A., Zheng, J., & Greenleaf, M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2282504 · Cited by 416 · cited 1×
“The used coulomb will be reflected in the battery changed state-of-health [29], and will further aggravate battery aging.”
MethodSelf-citationIsolated DC/DC Structure Based on Modular Multilevel Converter
Kenzelmann, S., Rufer, A., Dujic, D., Canales, F., & de Novaes, Y. R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2305976 · Cited by 371 · cited 1×
“implemented with multilevel modulation [19]–[21].”
Bragard, M., Soltau, N., Thomas, S., & De Doncker, R. W. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2085455 · Cited by 366
Gowaid, I. A., Adam, G. P., Massoud, A. M., Ahmed, S., Holliday, D., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306453 · Cited by 356 · cited 1×
“Recently, isolated modular multilevel dc/dc converter (iM2DC) consisting of two MMCs connected through a medium-frequency transformer has been proposed as a dc transformer in HVDC/MVDC grids [17], [18].”
BackgroundOrtiz, G., Biela, J., Bortis, D., & Kolar, J. W. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5542018 · Cited by 229 · cited 1×
“Although modular cascaded DAB converter [10]–[12] has been applied to”
MethodDC link stabilized field oriented control of electric propulsion systems
Sudhoff, S. D., Corzine, K. A., Glover, S. F., Hegner, H. J., & Robey, H. N. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.658200 · Cited by 211
Gowaid, I. A., Adam, G. P., Ahmed, S., Holliday, D., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2377719 · Cited by 183 · cited 1×
“Recently, isolated modular multilevel dc/dc converter (iM2DC) consisting of two MMCs connected through a medium-frequency transformer has been proposed as a dc transformer in HVDC/MVDC grids [17], [18].”
BackgroundPower electronics and future marine electrical systems
Ericsen, T., Hingorani, N., & Khersonsky, Y. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.861306 · Cited by 159
Analysis of battery current microcycles in autonomous renewable energy systems
Ruddell, A., Dutton, A. G., Wenzl, H., Ropeter, C., Sauer, D. U., Merten, J., Orfanogiannis, C., Twidell, J., & Vezin, P. (2002) · Journal of Power Sources · doi:10.1016/s0378-7753(02)00457-3 · Cited by 89 · cited 1×
“The battery manufacturer recommends the ripple current to be limited to the 20 h discharge rate (C/20) [27] since the temperature rises and expected lifetime decays with the increasing of ripple current [27], [28].”
Background
Research works printed but not linked: 1
- 2015, Effects of AC Ripple Current on VRLA Battery Life From Emerson Network Power
Cited by
Hybrid energy storage system for microgrids applications: A review
Hajiaghasi, S., Salemnia, A., & Hamzeh, M. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.12.017 · Cited by 585
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“can be used in combination with energy storage and active filtering functionalities in order to improve the availability of the complete on-board system [154].”
MethodChoudhury, S., Bajaj, M., Dash, T., Kamel, S. M., & Jurado, F. (2021) · Energies · doi:10.3390/en14185773 · Cited by 179
Energy Storage Systems for Shipboard Microgrids—A Review
Mutarraf, M. U., Terriche, Y., Niazi, K. A. K., Vasquez, J. C., & Guerrero, J. M. (2018) · Energies · doi:10.3390/en11123492 · Cited by 162
A Review of Recent Advances on Hybrid Energy Storage System for Solar Photovoltaics Power Generation
Sutikno, T., Arsadiando, W., Wangsupphaphol, A., Yudhana, A., & Facta, M. (2022) · IEEE Access · doi:10.1109/access.2022.3165798 · Cited by 161
“In several studies, multi-level converters were developed and used for power converters in HESS [105]–[108].”
A review of power electronics equipment for all-electric ship MVDC power systems
Castellan, S., Menis, R., Tessarolo, A., Luise, F., & Mazzuca, T. (2017) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.09.040 · Cited by 86
“active filtering functions is proposed in [63].”
BackgroundZheng, L., Kandula, R. P., & Divan, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3101482 · Cited by 85
“A MVdc collection system is regarded as more efficient compared to a LV collection grid due to the reduction in power cable loss and cost [16]–[18].”
MethodA Novel Virtual Resistor and Capacitor Droop Control for HESS in Medium-Voltage DC System
Chen, X., Zhou, J., Shi, M., Yan, L., Zuo, W., & Wen, J. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2894754 · Cited by 81
“Consequently, the ESs are of essential importance for MVDC to supply the PPL, minimize the impact of the PPL and propulsion motor and improve power quality [6].”
BackgroundChallenges for Zero-Emissions Ship
Reusser, C. A., & Osses, J. R. P. (2021) · Journal of Marine Science and Engineering · doi:10.3390/jmse9101042 · Cited by 73
“Energy produced by FCs is utilized as the main energy resource while batteries can be used to respond to the fast dynamics of the loads that FCs are not capable to cover [6].”
BackgroundGao, X., & Fu, L. (2020) · IEEE Access · doi:10.1109/access.2020.2981545 · Cited by 63
“However, the high power weapons known as pulse load has the dynamic characteristics of impulsive power with very high amplitude, which will seriously impact the IPS with limited capacity and relatively long responding time [5].”
BackgroundXie, R., & Li, H. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2794355 · Cited by 45
“CHIL results of iM2DC converter during dc side short-circuit fault [31].”
BackgroundSelf-citationDecentralized Control Algorithm for the Hybrid Energy Storage of Shipboard Power System
Faddel, S., Saad, A., Youssef, T. A., & Mohammed, O. A. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2899287 · Cited by 44
“In [10], a centralized controller was proposed to manage the fault ride through capability of the converters connected to the storage system.”
MethodLuo, W., Styński, S., Chub, A., Franquelo, L. G., Malinowski, M., & Vinnikov, D. (2021) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2020.3026169 · Cited by 36
Chen, P., Xiao, F., Liu, J., Zhu, Z., & Ren, Q. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3016029 · Cited by 34
On the Optimal Design of Hybrid-Electric Power Systems for Offshore Vessels
Valera, J. J., & Atutxa, I. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2883870 · Cited by 33
“1] or through bidirectional dc/dc converters in the case of dc distribution-based topologies [13], [16] [see Fig.”
BackgroundShrestha, A., Rana, L. B., Singh, A. K., Phuyal, S., Ghimire, A., Giri, R., Kattel, R., Karki, K., & Jha, S. K. (2019) · Energy Procedia · doi:10.1016/j.egypro.2019.02.121 · Cited by 32
“A number of researchers have presented the optimum design of the isolated hybrid system (IHS), to provide the energy access at the isolated area [7-10].”
BackgroundControl System to Balance Internal Currents of a Multilevel Current-Source Inverter
Cossutta, P., Aguirre, M. P., Engelhardt, M. A., & Valla, M. I. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2740846 · Cited by 25
“[1], power factor correctors [2] and active filters [3], motor”
BackgroundLee, N., Lee, J.-Y., Cheon, Y.-J., Han, S.-K., & Moon, G.-W. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2898584 · Cited by 22
“The advantage of the ACF topology is its zero-voltage switching (ZVS) capability [14]–[18], which makes a high-power-density design feasible for a 50–100 W satellite power converter with a 28 V bus voltage [1], [6].”
BackgroundAverage-Value Model for a Modular Multilevel Converter With Embedded Storage
Herath, N., & Filizadeh, S. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.3014793 · Cited by 21
“This type of application is popular in shipboard systems where both ac and dc systems exist [5].”
BackgroundModel Development and Predictive Control of a Low-Inertia DC Solid-State Transformer (SST)
Martin, S., Dong, X., & Li, H. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3159621 · Cited by 19
“The proposed control is beneficial to improve the efficiency of MMC-based dc SST by removing the core loss and winding loss associated with arm inductors, as well as mitigating low-order current harmonics.”
BackgroundInfluentialSelf-citationNovel multi‐terminal MMC‐based dc/dc converter for MVDC grid interconnection
Jafarishiadeh, S., Dargahi, V., Sadigh, A. K., & Farasat, M. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0164 · Cited by 18
Alacano, A., Valera, J. J., Abad, G., & Izurza-Moreno, P. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2730855 · Cited by 17
“Finally, it has to be mentioned that many other necessary works and challenging topics related to PEB-DCDS for vessels can be found in the specialized literature, such as for instance: solid state circuit breaker protections [20], innovative hybrid energy storage systems [21], or analysis for size and weight computati…”
BackgroundDecentralized Controller for Energy Storage Management on MVDC Ship Power System with Pulsed Loads
Faddel, S., Youssef, T. A., & Mohammed, O. A. (2018) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2018.8450147 · Cited by 17
“Energy storage system with isolated modular multilevel DC-DC converter was considered in [7], [8].”
MethodZhang, Y., Diao, L., Jin, Z., Xu, C., Pei, H., Wu, Q., & Zhang, J. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.134658 · Cited by 17
Sleiman, M., Al‐Haddad, K., Blanchette, H. F., & Kanaan, H. Y. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2784408 · Cited by 16
“IN RECENT years, modular multilevel converters (MMCs) have reserved a “first seat” in the high-voltage high-power converters contest and have been adopted by many world class manufacturers for various applications, including HVdc [1], [2], motor drives [3]–[5], electric ship power distribution systems [6], [7], off-sh…”
BackgroundBusarello, T. D. C., Paredes, H. K. M., Pomílio, J. A., & Simões, M. G. (2018) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2018.0314 · Cited by 15
Multi‐object control of an isolated DC–DC modular multilevel converter
Chen, Y., Zhao, S., Li, Z., & Kang, Y. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0151 · Cited by 14
Decentralized Energy Management of Hybrid Energy Storage on MVDC Shipboard Power System
Faddel, S., Saad, A., & Mohammed, O. A. (2018) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2018.8544604 · Cited by 14
“In [7], [8], centralized controller strategy for controlling modular converters connected to the storage system was proposed.”
BackgroundZhang, Y., Diao, L., Pei, H., Wu, Q., Zhang, J., Du, H., & Xu, C. (2023) · Ocean Engineering · doi:10.1016/j.oceaneng.2023.116043 · Cited by 13
AN OVERVIEW OF DESIGN, CONTROL, POWER MANAGEMENT, SYSTEM STABILITY AND RELIABILITY IN ELECTRIC SHIPS
Ni, K., Hu, Y., & Xinhua, L. (2017) · Prace Naukowe Uniwersytetu Ekonomicznego we Wrocławiu · doi:10.5277/ped170211 · Cited by 12
“In [32], a hybrid energy storage system (ESS) based on isolated modular multilevel DC/DC converter was proposed with active filter function for shipboard medium-voltage direct current (MVDC) system applications to improve the bus power quality and achieve superior fault response.”
Prasad, S. G., Srikanth, K., & Rajanna, B. V. (2018) · Indonesian Journal of Electrical Engineering and Computer Science · doi:10.11591/ijeecs.v11.i1.pp60-73 · Cited by 11
“INTRODUCTION Renewable generation affects power quality due to its nonlinearity, since solar generation plants and wind power generators must be connected to the grid through high-power static PWM converters [1].”
BackgroundGao, X., Fu, L., Zhang, Y., & Ji, F. (2022) · Journal of Power Electronics · doi:10.1007/s43236-022-00514-x · Cited by 10
“In all kinds of ESDs, the hybrid energy storage system (HESS) is a promising solution since it can take the power and energy requirements of the IPS into account at the same time [5, 6].”
BackgroundEstágio de Entrada com Dupla Funcionalidade Aplicado a uma UPS Trifásica de alto Desempenho
Venturini, W. A., Jank, H., Bisogno, F. E., Martins, M. L. D. S., & Pinheiro, H. (2018) · Eletrônica de Potência · doi:10.18618/rep.2018.2.2776 · Cited by 9
“A utilização deste equipamento tem se popularizado na literatura e na indústria para a aquisição de resultados em tempo real com alta fidelidade, sendo uma alternativa que reduz o custo, o tempo de desenvolvimento e o time-tomarket, principalmente para sistemas de potência elevada [32]-[35].”
BackgroundWu, Y., Wang, W. N., Tang, F., & Wu, X. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.110045 · Cited by 8
MMC-Based High Gain Solid-State Transformers for Energy Storage Applications
Xing, D., Li, X., Zhang, Y., Cheng, Q., Zhang, Z., Hu, B., Agarwal, A., Wang, J., & Guenther, R. (2021) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec42165.2021.9487233 · Cited by 8
Chen, P., Liu, J., Xiao, F., Zhu, Z., & Ren, Q. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9367754 · Cited by 7
“To withstand the high DC voltage of the vessel IPS, modular converters are investigated by researchers [3]–[6],”
BackgroundAdvances in Data‐Driven Modeling and Control of Naval Power Systems
Khazaei, J., & Hosseinipour, A. (2022) · Wiley eBooks · doi:10.1002/9781119812357.ch21 · Cited by 7
Wang, S., Vozikis, D., Ahmed, K. H., Holliday, D., & Williams, B. W. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3097147 · Cited by 7
“bypassed [64], and the DC-Shunt ESS in Scheme-IV can be blocked [26]; therefore, negligible losses are incurred.”
BackgroundAnalysis and Design of a Modular Self-Balance High-Voltage Input DC–DC Topology
Xiao, Z., He, Z., Guan, R., Li, Z., Xu, Q., Chen, Y., & Luo, A. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3140898 · Cited by 6
Venturini, W. A., Lenz, J. M., Jank, H., Bisogno, F. E., & Pinheiro, J. R. (2018) · Eletrônica de Potência · doi:10.18618/rep.2018.4.0001 · Cited by 4
Distributed energy storage systems: Hybrid energy storage systems
Magesh, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22013-5.00011-3 · Cited by 3
A new insertion index selection method to control modular multilevel converters
Sleiman, M., Grégoire, L.-A., Blanchette, H. F., Kanaan, H. Y., & Al‐Haddad, K. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096014 · Cited by 3
“In recent years, Modular Multilevel Converters (MMC) have been adopted by many world class manufacturers for various applications, including HVDC [1], motor drives [2]– [4], electric ship power distribution systems [5], [6], off-shore wind farm interfaces [7], [8], solid state transformers [9], and STATCOMs [10], [11].”
BackgroundPower Management System (PMS) Sebagai Kontrol Utama Dalam Perkembangan Power Listrik Kapal
Darmana, E., & Pujiyanto, F. (2021) · Majalah Ilmiah Bahari Jogja · doi:10.33489/mibj.v19i2.268 · Cited by 3
“Algorima multi fungsi control dirancang untuk mendapatkan suplemen energi, Active Power Filter (APF), dan membatasi gangguan arus(Mo & Li, 2017).”
BackgroundControl and Optimization of Energy Storage in AC and DC Power Grids
Mohamed, S. (2019) · FIU - Digital Commons (Florida International University) · doi:10.25148/etd.fidc007679 · Cited by 3
“In [204], a centralized controller was proposed to manage the fault ride through-capability of the converters connected to the storage system.”
MethodThe Role of Energy Storage Systems in Microgrids Operation
Fang, S., & Wang, Y. (2021) · Power systems · doi:10.1007/978-3-030-59750-4_5 · Cited by 2
The design of an active filter for DC microgrids
Li, L., Yu, X., Chai, Z., Zhu, X., Li, G., & Shi, Y. (2025) · Journal of Physics Conference Series · doi:10.1088/1742-6596/3090/1/012011 · Cited by 2
Introduction to the Multi-energy Maritime Grids
Fang, S., & Wang, H. (2021) · Springer series on naval architecture, marine engineering, shipbuilding and shipping/Springer series on naval architecture, marine engineering, shipbuildung and shipping · doi:10.1007/978-981-33-6734-0_1 · Cited by 2
Mechanism of Power Quality Deterioration Caused by Multiple Load Converters for the MVDC System
Huang, H., Liu, F., & Zha, X. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.864211 · Cited by 2
Operation, control, and simulation of modular multilevel converters with embedded energy storage
Mudiyanselage, H., & Herath, N. (2019) · Mspace (University of Manitoba) · Cited by 2
Efficient Energy Storage Systems for Wind Power Application
Sahu, P. K., Jena, S., & Sahoo, U. (2021) · Energy Storage · doi:10.1002/9781119555599.ch3 · Cited by 1
Two-Switch Reset Winding Forward Converter with Low Input Current Ripple
Lee, J.-Y., Lee, C.-M., & Han, S.-K. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591994 · Cited by 1
“Since the input current ripple is decreased and the RMS current is smaller, the battery lifetime is improved [7][8].”
BackgroundA Review of Control Strategies for Hybrid Ships Energy Management System
Tian, L. F., Hui, C., & Yang, X. (2023) · Lecture notes in civil engineering · doi:10.1007/978-981-99-4291-6_55 · Cited by 1
Real Time Impact Control on Charging Energy Storage For Shipboard Power SystemsPreprint
Luo, Y., Srivastava, S., Mohanpurkar, M. U., Stevic, S., & Hovsapian, R. O. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1801.05797 · Cited by 1
An optimal frequency division control for hybrid energy storage
Wang, A., Huang, P., & Zhu, J. G. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056080
Vivek, K. (2021) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2021.35978
Designing and simulation of energy storage system for an institutional building
Alnaji, I. K. B. (2020)
Viatkin, A. (2023) · Springer theses · doi:10.1007/978-3-031-24712-5_1
Murugu, M., Rajagopalan, A., Sreedevi, V. T., Sitharthan, R., & Kanimozhi, R. (2024) · Wiley eBooks · doi:10.1002/9781394249374.ch10
Patel, Z. S., Touileb, R., Quadar, N., Chaibi, H., Saadane, R., & Jakimi, A. (2025) · International Conference on Innovative Research in Applied Science, Engineering and Technology (IRASET) · doi:10.1109/iraset64571.2025.11008134
Chen, P., Zhao, J., Zhao, L., Liu, K., Zhou, J., & Deng, F. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.110933
A Review of Input Current Ripple Reduction Techniques in Non-Isolated DC–DC Boost Converters
Limon, M., Gaillard, A., & Poure, P. (2026) · Energies · doi:10.3390/en19194557
Metadata
- Authors
- Mo, R., & Li, H.
- Affiliations
- Florida State University (US)
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2017-03
- Volume
- 5
- Issue
- 1
- Pages
- 79-87
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2565514794
- Cited by
- 59
- References
- 29
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 6 · 2021: 12 · 2020: 5 · 2019: 6 · 2018: 13 · 2017: 7
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Emerging and Selected Topics in Power Electronics (publishedVersion)
- Funders
- Office of Naval Research (N000141410198)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- hybrid energy storage, DC-DC converter, active power filter, fault current limitation, power quality, virtual impedance control, battery life, fault recovery
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.