The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Sizing Strategy of Distributed Battery Storage System With High Penetration of Photovoltaic for Voltage Regulation and Peak Load Shaving
Open accessAbstract
This paper proposes an effective sizing strategy for distributed battery energy storage system (BESS) in the distribution networks under high photovoltaic (PV) penetration level. The main objective of the proposed method is to optimize the size of the distributed BESS and derive the cost-benefit analysis when the distributed BESS is applied for voltage regulation and peak load shaving. In particular, a system model that includes a physical battery model and a voltage regulation and peak load shaving oriented energy management system (EMS) is developed to apply the proposed strategy. The cost-benefit analysis presented in this paper considers factors of BESS influence on the work stress of voltage regulation devices, load shifting and peaking power generation, as well as individual BESS cost with its lifetime estimation. Based on the cost-benefit analysis, the cost-benefit size can be determined for the distributed BESS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impact of high PV penetration on voltage profiles in residential neighborhoods
Tonkoski, R., Turcotte, D., & El-Fouly, T. H. M. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2191425 · Cited by 557
Solar PV Integration Challenges
Katiraei, F., & Aguero, J. (2011) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2011.940579 · Cited by 550
Distributed Power Generation Planning And Evaluation
Willis, H. L., & Scott, W. G. (2000) · Medical Entomology and Zoology · Cited by 489
Liu, X., Aichhorn, A., Liu, L., & Li, H. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2177501 · Cited by 486
Self-citationPower Distribution Planning Reference Book
Willis, H. L. (2004) · doi:10.1201/9781420030310 · Cited by 467
Ueda, Y., Kurokawa, K., Tanabe, T., Kitamura, K., & Sugihara, H. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924447 · Cited by 226
Chua, K. H., Lim, Y. S., Taylor, P., Morris, S., & Wong, J. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2195035 · Cited by 159
How Depth of Discharge Affects the Cycle Life of Lithium-Metal-Polymer Batteries
Guena, T., & Leblanc, P. (2006) · International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intlec.2006.251641 · Cited by 133
Voltage Regulation in Radial Distribution Feeders with High Penetration of Photovoltaic
Tonkoski, R., & Lopes, L. A. C. (2008) · doi:10.1109/energy.2008.4781021 · Cited by 122
Battery Storage System sizing in distribution feeders with distributed photovoltaic systems
Venu, C., Riffonneau, Y., Bacha, S., & Baghzouz, Y. (2009) · doi:10.1109/ptc.2009.5282093 · Cited by 95
Cited by
Kouro, S., Leon, J. I., Vinnikov, D., & Franquelo, L. G. (2015) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2376976 · Cited by 1,197
Battery energy storage system size determination in renewable energy systems: A review
Yang, Y., Bremner, S., Menictas, C., & Kay, M. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.047 · Cited by 977
Self-citationDas, C. K., Bass, O., Kothapalli, G., Mahmoud, T. S., & Habibi, D. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.068 · Cited by 656
Evolution of microgrids with converter-interfaced generations: Challenges and opportunities
Hossain, M. A., Pota, H. R., Hossain, M. J., & Blaabjerg, F. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.01.038 · Cited by 309
Wong, L. A., Ramachandaramurthy, V. K., Taylor, P., Ekanayake, J. B., Walker, S. L., & Padmanaban, S. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.12.015 · Cited by 301
Metadata
- Authors
- Yang, Y., Li, H., Aichhorn, A., Zheng, J., & Greenleaf, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-03
- Volume
- 5
- Issue
- 2
- Pages
- 982-991
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2146436035
- Cited by
- 416
- References
- 12
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sizing Strategy of Distributed Battery Storage System With High Penetration of Photovoltaic for Voltage Regulation and Peak Load Shaving. https://app.cochat.ai/papers/10.1109/tsg.2013.2282504
- The paper
- Yang, Y., Li, H., Aichhorn, A., Zheng, J., & Greenleaf, M. (2014). Sizing Strategy of Distributed Battery Storage System With High Penetration of Photovoltaic for Voltage Regulation and Peak Load Shaving. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2013.2282504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.