The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Review of Power Electronic Converters for Variable Speed Pumped Storage Plants: Configurations, Operational Challenges, and Future Scopes
Abstract
Pumped storage power plant has gained a high level of attention in recent years, mainly because of its ability to act as a large-scale energy storage option and to improve power system flexibility. Doubly fed asynchronous machine with the partially rated power electronic converter is adopted in pumped storage plants to provide variable speed operation and improve energy efficiency. This paper summarizes the power converter topologies in large rated variable speed pumped storage plant (VSPSP), also covers the suitability of each converter topology, modulation techniques, and parallel converter schemes. Also, it presents operational issues of the parallel converter system in VSPSP such as the shutdown of the plant due to insufficient converter redundancy and lack of fault-tolerant control schemes, a power outage due to the inadequacy of converter protection system, and unbalanced power sharing due to circulating current. Furthermore, the reliable mitigating/additional techniques are discussed for future research. It concludes that the refinement of these aforementioned issues will provide continuous operation of the plant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Techno-economic review of existing and new pumped hydro energy storage plant
Deane, J. P., Ó Gallachóir, B. P., & McKeogh, E. J. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2009.11.015 · Cited by 640
Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278
Cited by
Salem, A., Van Khang, H., Robbersmyr, K. G., Norambuena, M., & Rodriguez, J. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011908 · Cited by 285
Zhu, H., Goh, H. H., Zhang, D., Ahmad, T., Liu, H., Wang, S., Li, S., Liu, T., Dai, H., & Wu, T. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.129809 · Cited by 131
Metadata
- Authors
- Joseph, A., & Chelliah, T. R.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2018-03
- Volume
- 6
- Issue
- 1
- Pages
- 103-119
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2619928684
- Cited by
- 180
- References
- 2
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of Power Electronic Converters for Variable Speed Pumped Storage Plants: Configurations, Operational Challenges, and Future Scopes. https://app.cochat.ai/papers/10.1109/jestpe.2017.2707397
- The paper
- Joseph, A., & Chelliah, T. R. (2018). A Review of Power Electronic Converters for Variable Speed Pumped Storage Plants: Configurations, Operational Challenges, and Future Scopes. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2017.2707397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.