Abstract
In this paper, a two-level fault-tolerant voltage source inverter (VSI) for permanent magnet drives is systematically designed and tested. A standard two-level inverter consists of three legs. In this case of fault-tolerant inverter, a redundant leg is added that replaces the faulted leg. Faulted leg isolation and redundant leg insertion are done by using independent back-to-back-connected thyristors. The proposed inverter provides tolerance to both short-circuit and open-circuit faults of the switching devices. The postfault performance is the same as the normal prefault operation and fault compensation is fast enough such that there is negligible disturbance in the drive operation. The fault tolerance of the inverter is verified using field-oriented control of a permanent magnet synchronous motor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“According to [238], [239], power semiconductor device damages account for approximately 35% of all ASD faults.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [239]
In the citing paper
“Recently, phase redundancy approaches [239], [309] have gained popularity due to their full fault recovery without oversizing the drive.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [239]
Citations
Cites
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 1×
“Several fault-tolerant topologies are available in the literature [5]; some of them reconfigure the standard inverter topology and reformulate the current references so that the rotating”
BackgroundFault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 2×
“According to [14], the open-circuit fault of the IGBT can be detected by inserting voltage sensors at desired locations.”
BackgroundMethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374 · cited 1×
“faulted leg has to be connected to the midpoint of the dc voltage link, created using the use of two capacitors [6].”
MethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370 · cited 3×
“Moreover, the current dc component generates unequal current stress in the upper and lower transistors in the inverter, which may cause thermal defects in the transistors [1].”
BackgroundInfluentialFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304 · cited 2×
“[15] suggested the open switch fault detection by analyzing the current vector trajectory and of the instantaneous frequency in the faulty mode.”
BackgroundMethodFault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299 · cited 1×
“A simplified version of [7] has been developed in [8], where only fast-acting semiconductor fuses are used to isolate”
BackgroundFuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270 · cited 1×
“IGBT are available in the literature [13]–[16].”
Research works printed but not linked: 2
- schwab, 2003, Reliability evaluation of a permanent magnet synchronous motor drive for an automotive application, Proc Eur Conf Power Electron Appl
- thorsen, 1995, A survey of the reliability with an analysis of faults on the variable frequency drives in industry, Proc Conf Rec 6th Eur Power Electron Appl Conf, 1033
Cited by
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
The state of the art of wind energy conversion systems and technologies: A review
Cheng, M., & Zhu, Y. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.08.037 · Cited by 600
“Various topologies have been proposed to endow a standard three-phase converter with fault tolerant capabilities [108,109].”
BackgroundSurvey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
“duced for Y-connected three-phase motor drives in which an auxiliary fourth leg is added to the standard two-level inverter topology [8], [9], [26]–[32], and the fourth leg is connected”
BackgroundA New Boost Switched-Capacitor Multilevel Converter With Reduced Circuit Devices
Barzegarkhoo, R., Moradzadeh, M., Zamiri, E., Madadi Kojabadi, H., & Blaabjerg, F. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2751419 · Cited by 389
“can be based on either impedance Z-source or multilevel voltage source inverters (MLVSIs) [3]–[9].”
BackgroundEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Metadata
- Authors
- Errabelli, R. R., & Mutschler, P.
- Affiliations
- Technische Universität Darmstadt (DE)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-02
- Volume
- 27
- Issue
- 2
- Pages
- 500-508
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2079590925
- Cited by
- 278
- References
- 19
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 10 · 2023: 10 · 2022: 17 · 2021: 25 · 2020: 19 · 2019: 23 · 2018: 25 · 2017: 25 · 2016: 22 · 2015: 23 · 2014: 29 · 2013: 24 · 2012: 13
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- fault-tolerant inverter, voltage source inverter, permanent magnet synchronous motor, short-circuit faults, open-circuit fault, field-oriented control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives. https://app.cochat.ai/papers/10.1109/tpel.2011.2135866
- The paper
- Errabelli, R. R., & Mutschler, P. (2012). Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2011.2135866
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.