Experimental Investigation of Inverter Open-Circuit Fault Diagnosis for Biharmonic Five-Phase Permanent Magnet Drive
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This paper proposes a procedure that is suitable for experimental investigation of real-time open-switch and open-phase faults diagnosis of a five-leg voltage source inverter feeding a five-phase biharmonic permanent magnet synchronous machine (PMSM). The algorithm is based on the specific characteristics of multiphase machines, which allows inverter fault detection with sufficient robustness of the algorithm in the presence of fundamental and third harmonic components. First, the inverter fault effects analysis is achieved in the characteristic subspaces of the five-phase PMSM. Specificities that are interesting for the elaboration of a real-time fault detection and identification (FDI) process are highlighted. Original and particular algorithms are used for an accurate 2-D normalized fault vector extraction in a defined fault reference frame. This frame is dedicated only for FDI. To ensure the high immunity of the FDI process against transient states, a particular normalization procedure is applied. The normalized diagnostic signals are formulated from the defined frame and other variables derived from the reference and measured currents. Simulation and experimental results of open-switch and open-phase faults are provided to validate the proposed algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Therefore, due to the hazardous effects of this type of the damage, many methods of its detection have been developed in last decades [253].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [253]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135 · cited 2×
“The method proposed in this paper belongs to the family of the signal-based methods [9] and especially considering only current signals, as in [12]-[17] and [21]-[22].”
BackgroundMethodAn Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019 · cited 1×
“Moreover, the power switches and the electronic control boards are also considered as the main sources of their failures [4], [5].”
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985 · cited 2×
“Their evaluation and classification have been addressed in [6] and [9].”
BackgroundSurvey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440 · cited 1×
“Therefore, fault detection is useful in order to adopt a control reconfiguration [7]-[8].”
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377 · cited 1×
“3 In [14] and [15], the diagnostic algorithms have been proposed for OSF in the case of sinusoidal 3-Φ PMSM.”
BackgroundOpen-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300 · cited 1×
“In [23] and [24], for almost sinusoidal five-phase machines, it is shown clearly, as in [22], that the inverter fault induces a fault current component in the second plane instead of a near zero current component under a healthy operation of the VSI.”
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298 · cited 1×
“In [14] and [15], the diagnostic algorithms have been proposed for OSF in the case of sinusoidal 3- PMSM.”
Jung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271 · cited 1×
“additional voltage sensors, as addressed in [10] and [11], or observers development, as proposed in [18]–[20].”
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262 · cited 1×
“Methods based on voltage signals are not considered in this work since they require additional voltage sensors, as addressed in [10]-[11], or observers development, as proposed in [18]-[20].”
BackgroundGuzman, H., Duran, M. J., Barrero, F., Zarri, L., Bogado, B., Gonzalez Prieto, I., & Arahal, M. R. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2418732 · Cited by 231 · cited 1×
“In [23] and [24], for almost sinusoidal five-phase machines, it is shown clearly, as in [22], that the inverter fault induces a fault current component in the second plane instead”
Research works printed but not linked: 2
- Y. Gritli, A. Tani, C. Rossi, D. Casadei, "Closed-loop control impact on condition monitoring of high-resistance connections in PMSM based on power signature analysis," in Proc. 42th IECON, Oct. 2016, pp. 6966-6970.
- Eric Semail (M'02) graduated from the Ecole Normale Superieure, Paris, France, in 1986, and received the Ph.D. degree with a thesis entitled "Tools and studying method of polyphase electrical systems-Generalization of the space vector theory" from the University of Lille, France, in 2000. He became an Associate Professor at the Engineering School of Arts et Metiers ParisTech, Lille, France, in 2001 and a Full Professor in 2010. In the Laboratory of Electrical Engineering of Lille (L2EP), France, his fields of interest include design, modeling, and control of multiphase electrical drives (converters and ac drives). More generally, he studies, as a Member of the Control team of L2EP, multimachine and multiconverter systems. Fault tolerance for electromechanical conversion at variable speeds is one of the applications of the research with industrial partners in fields such as automotive, marine, and aerospace. Since 2000, he has collaborated on the publication of 27 scientific journals, 64 International Congresses, 5 patents, and 2 chapters in books.
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Therefore, due to the hazardous effects of this type of the damage, many methods of its detection have been developed in last decades [253].”
BackgroundYepes, A. G., López, Ó., González‐Prieto, I., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030208 · Cited by 150
Liu, Z., Fang, L., Jiang, D., & Qu, R. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3153797 · Cited by 106
“[8] proposed a real-time FD method for both OCF and OSF by analyzing the trajectories of the phase currents in fault reference frame but does not apply to faults on several stator phases simultaneously.”
MethodYepes, A. G., González‐Prieto, I., López, Ó., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030221 · Cited by 96
Ahmed, H. M., Jlassi, I., Cardoso, A. J. M., & Bentaallah, A. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3132236 · Cited by 59
“The reference and measured currents in Concordia reference frame of five-phase PMSM is addressed in [35].”
BackgroundResilient Actuator Fault Estimation for Discrete-Time Complex Networks: A Distributed Approach
Liu, Y., Wang, Z., & Zhou, D. (2020) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2020.3033710 · Cited by 55
Sun, J., Zheng, Z., Li, C., Wang, K., & Li, Y. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3135280 · Cited by 46
Gonçalves, P. F. C., Cruz, S. M. A., & Mendes, A. M. S. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3120239 · Cited by 46
“The available methods for the detection of OPFs are either model based, as the observer-based strategy in [9], or signal based, as the strategies in [10]–[14], which rely on the analysis of the measured currents.”
MethodFully Simulated Data-Driven Domain Generalized Method for Multiphase Converters Fault Diagnosis
Xu, H., Liu, Z., Wang, G., Jiang, D., & Sun, W. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3461159 · Cited by 45
“This characteristic implies that normalization methods previously effective in fault detection for three phase systems often fail in multiphase systems [25].”
Chen, H., He, J., Demerdash, N. A. O., Guan, X., & Lee, C. H. T. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3000109 · Cited by 38
“with an open-phase fault, due to the compensation action of the closed-loop vector-controlled drives [11], [12].”
BackgroundSun, J., Li, C., Zheng, Z., Wang, K., & Li, Y. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3150759 · Cited by 38
“In [22]–[24], centroid based OS diagnosis methods are proposed for five-phase machines and series-connected six-phase machines.”
MethodAhmadi, S., Poure, P., Saadate, S., & Khaburi, D. A. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3017923 · Cited by 33
Current observer-based online open-switch fault diagnosis for voltage-source inverter
Chen, Y., Zhang, J.-J., & Chen, Z.-Y. (2019) · ISA Transactions · doi:10.1016/j.isatra.2019.09.019 · Cited by 34
Vu, D. T., Nguyen, N. K., Semail, E., & Moraes, T. J. D. S. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0056 · Cited by 24
Self-citationJiang, X., Wang, S., Li, J., Wu, D., Huang, W., & Han, Z. (2021) · Chinese Journal of Aeronautics · doi:10.1016/j.cja.2021.04.027 · Cited by 22
Circulating Current-Based Open-Circuit Fault Diagnosis for Parallel Inverters
Fang, J., Li, M., Ding, S., & Hang, J. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3386805 · Cited by 18
“…fault diagnosis method mainly uses some signal processing methods, such as slope method, current vector method based on Park transform, and normalized average current method, to process the fault signal and use the processed signal for accurate fault diagnosis [4], [5], [6], [7], [8], [9], [10].”
MethodYanghong, T., Hai-xia, Z., & Zhou, Y. (2018) · Energies · doi:10.3390/en11102571 · Cited by 16
“For detection and discrimination of OCF in a five-leg voltage source inverter feeding a five-phase biharmonic PMSG, the investigation into real-time faults diagnosis has been conducted [21].”
MethodWang, K., Jiang, X., Wang, S., & Han, Z. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.08.149 · Cited by 16
Guo, L., Wang, K., Wang, T., Cao, R., & Li, F. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3331134 · Cited by 13
“To demonstrate the superiority, the proposed method is compared with these methods especially developed for multiphase system considering nonideal cases [35], [36], [37].”
BackgroundMethodInfluentialZafari, Y., Mazinan, A. H., & Majidabad, S. S. (2017) · Automatika · doi:10.1080/00051144.2018.1478928 · Cited by 11
“Nowadays, various real-time complex controllers can be implemented using FPGAs (Field Programmable Gate Arrays) and DSPs (Digital Signal Processors) [6,7].”
BackgroundLiu, J., Weng, X., Sun, Y., Tang, X., Gao, Y., Yang, S., Wei, Z., & Jiang, X. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3532912 · Cited by 10
Liang, X., Talha, M., Pannell, J., Su, H., & Bowes, A. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3536426 · Cited by 9
“…or micro-controller is used for experiments to acquire datasets for inverter open-switch faults [1], [2], [3], [4], [5], [6], [7], [8], [9], [10], [11], [12], [13], [14], [15], [16], [17], [18], [19], [20], but these controllers have limitations, including the high computation time, small system…”
InfluentialGonçalves, P. F. C., Cruz, S. M. A., & Mendes, A. M. S. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9254472 · Cited by 9
“Contrary to three-phase machines, OPFs in multiphase machines lead to unbalanced currents in the remaining phases in post-fault operation, making difficult to diagnose these faults based on the information contained in the phase currents [12], [14].”
BackgroundMethodZhang, Z., Wu, Y., & Qi, S. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.1594 · Cited by 9
Chikondra, B., Vaish, R., & Dwivedi, U. D. (2024) · International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intelec60315.2024.10679011 · Cited by 8
“In [12] a real-time fault detection approach for both open circuit and open-phase faults has been suggested based on trajectories of the phase currents in the fault reference frame.”
BackgroundPham, T. H., Lefteriu, S., Duviella, É., & Lecœuche, S. (2020) · ISA Transactions · doi:10.1016/j.isatra.2020.06.009 · Cited by 8
Diagnosis of Open-Phase Faults and High Resistance Connections in Six-Phase PMSM Drives
Gonçalves, P. F. C., Cruz, S. M. A., & Mendes, A. M. S. (2020) · International Conference on Smart Energy Systems and Technologies (SEST) · doi:10.1109/sest48500.2020.9203465 · Cited by 7
“A signal-based method that relies on the analysis of a two dimensional current vector in a fault reference frame is suggested in [8] to diagnose OPFs in five-phase PMSMs.”
MethodTrabelsi, M., & Semail, E. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12083 · Cited by 8
“The fault diagnosis problem in the case of the biharmonic multiphase PMSM is addressed in [30].”
BackgroundSelf-citationLiu, G., Farahat, A., Chen, Q., Zhang, J., & Wang, X. (2023) · Journal of Power Electronics · doi:10.1007/s43236-023-00614-2 · Cited by 7
“Last decade, a great deal of research was focused on open-circuit FTC, which was highly significant, especially for open-end winding faults [22] and inverter open circuit faults [23].”
BackgroundTian, B., Lu, R., & Wang, K. (2023) · Journal of Power Electronics · doi:10.1007/s43236-023-00642-y · Cited by 6
“The authors of [14, 15] calculated a two-dimensional fault indicator from the reference and measured phase currents.”
BackgroundParameter Identification-Based Diagnosis of Open-Circuit Fault in Dual Three-Phase PMSM Drives
Zhang, T., Mao, Y., Zhang, Y., Chen, X., Wang, Z., & Wang, X. (2025) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2025.3611939 · Cited by 6
“Generally, the fault diagnosis methods of PMSM drives can be categorized as model-based [13], [14], signal-based [15], [16], [17], and data-driven methods [18], [19], [20].”
Auto-adaptive and Dynamical Clustering for Open-Circuit Fault Diagnosis of Power Inverters
Pham, T. H., Lefteriu, S., Labarre, C., Duviella, É., & Lecœuche, S. (2019) · European Control Conference (ECC) · doi:10.23919/ecc.2019.8796047 · Cited by 5
“The latter disadvantage motivates us to develop a current-based method, the load independence being ensured by simply normalizing the current data [1], [6].”
BackgroundMethodInfluentialQiu, H., Zhao, X., Yang, C., Yi, R., & Wei, Y. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0446 · Cited by 5
Auto-adaptive and Dynamical Clustering for Double Open-Circuit Fault Diagnosis of Power Inverters
Pham, T. H., Lefteriu, S., Duviella, É., & Lecœuche, S. (2019) · Conference on Control and Fault-Tolerant Systems · doi:10.1109/systol.2019.8864777 · Cited by 5
“For the closed loop system, the reference currents in the controller may be used for constructing feature variables [6].”
MethodDirect torque control of two induction motors fed by a Z‐source five‐leg power inverter
Derbane, A., Tabbache, B., & Ahriche, A. (2020) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12483 · Cited by 5
A Mixed Logical Dynamic Model-Based Open-Circuit Fault Diagnosis Method for Five-Phase PMSM Drives
Huang, W., Huang, Y., Luo, L., & Zhou, L. (2023) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems59686.2023.10344412 · Cited by 4
“Later, the joint approach above is further optimized by adopting the current phase angle as an auxiliary diagnostic variable, which can also detect the fault of a single power device [13].”
MethodChen, H., He, J., Demerdash, N. A. O., & Nejadi-Koti, H. (2018) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2018.8544660 · Cited by 4
“In the closed-loop vectorcontrolled drive system, open-phase fault results in a 180° phase shift between phase currents in the remaining two phases for the three-phase system, thus the remaining two phase currents are still symmetrical, while an asymmetry appears between the remaining four phases for the five-phase ma…”
BackgroundMethodMoraes, T. J. D. S., Trabelsi, M., Nguyen, N. K., Semail, E., & Meinguet, F. (2020) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0777 · Cited by 4
“These variables belong to subspace which are not contributing to the torque: Signal equal to zero in normal operation: either by considering error between signal in fault and signal in normal operation [20], [28] or by considering a physical signal [18], [22] which is intrinsically equal to zero in normal operation mu…”
BackgroundSelf-citationOnline Fault Diagnosis for Multiple Open-Circuit Faults in Multiphase Drives with Current Harmonics
Lenz, R., Kugi, A., & Kemmetmüller, W. (2024) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem60801.2024.10700349 · Cited by 3
“Typically, the averaging is performed over a full cfp see, e.g., [13], [14], [18].”
BackgroundWang, S., Li, Q., Jiang, X., Xu, D., Li, Y., & Gao, Y. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8922056 · Cited by 3
“If the open-circuit fault cannot be detected and solved in time, it may lead to the broken of whole system [7]-[10].”
BackgroundCurrent Trajectory-Based Fault Detection and Fault Tolerant Control for Three-phase Induction Drives
Tousizadeh, M., Seng, H., & Rahim, N. A. (2021) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit46573.2021.9453527 · Cited by 4
“Apart from three-phase motor drive, some researchers also explored OCF detection methods for multiphase (more than three phases) machines [11], [12], [25], [26].”
BackgroundTalha, M., Liang, X., Pannell, J., Bowes, A., & Su, H. (2024) · IEEE/IAS Industrial and Commercial Power Systems Technical Conference · doi:10.1109/icps60943.2024.10563400 · Cited by 3
“However, most of them are dealing with motor drive systems [2], [3], [5], [9], [11], [12], or other applications [13], [20], only few papers studied open-switch faults for DG interfacing inverters in microgrids [6].”
BackgroundCui, R., Yu, S., & Li, S. (2022) · Machines · doi:10.3390/machines10100829 · Cited by 3
“In addition, in [24,25], original and particular algorithms are proposed for the open-switch fault and open-phase fault detection based on a five-phase PMSM; and the adoption of the normalized variables make the detection method completely independent of operating conditions.”
BackgroundWang, Q., Tan, Q., Guo, C., & Tian, B. (2025) · Journal of Power Electronics · doi:10.1007/s43236-025-01105-2 · Cited by 2
Chen, W., Liu, Z., Wang, Z., & Li, C. (2025) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3594147 · Cited by 2
“Trabelsi et al. [31] proposed an improved Park’s vector diagnosis method, which is suitable for five-phase PMSM under the condition of coexistence of fundamental wave and third harmonic.”
Generalized Static Fault Diagnosis for Multi-phase Inverter in Motor Drives
Wu, Y., Han, W., & Ma, R. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927271 · Cited by 2
“In [8], the authors introduced a procedure of real-time open-switch and open-phase faults diagnosis of a five-leg voltage source inverter feeding a five-phase biharmonic permanent magnet synchronous motor (PMSM).”
BackgroundJadidi, S., & Liang, X. (2024) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias55788.2024.11023740 · Cited by 1
“[4], [11], [20] Explore complex scenarios involving multiple faults.”
Bounasla, N., & Barkat, S. (2025) · International Journal of Systems Assurance Engineering and Management · doi:10.1007/s13198-025-02926-x · Cited by 1
“What justifies the increasing interest in multiphase drives is their reliability, power segmentation, higher efficiency, and fault tolerance capability (Zhou et al. 2019; Holakooie et al. 2018; Priestley et al. 2018; Trabelsi et al. 2018; Wang et al. 2017).”
Multiswitch Fault-detection for VSI fed Multiphase Motor Drive Based on Machine Learning
Chikondra, B., Gonuguntla, V., Zaabi, O. A., Behera, R. K., & Veluvolu, K. C. (2022) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes56012.2022.10080697 · Cited by 1
“A real-time fault detection method for open circuit and open-phase faults has been proposed in [12] by analyzing the trajectories of the phase currents in the fault reference frame; however, this approach is inapplicable to simultaneous failures on multiple stator phases.”
BackgroundMethodTu, X., Wang, D., Wang, B., Mwaigaga, E. P., & Wang, X. (2023) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems59686.2023.10344740 · Cited by 1
“The fault tolerance and operational reliability can be greatly improved [8].”
BackgroundMini, Y. (2021) · theses.fr (ABES) · doi:10.70675/934e02ffz0549z463fz8664za2205106c300 · Cited by 1
Fault Diagnosis Method for Power switch in Dual-winding PM Motor System
Li, J., Huang, W., Gao, Y., & Jiang, X. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9367879 · Cited by 1
Jiang, S., Wang, P., Wang, W., Wei, W., & Xu, D. (2021) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems52562.2021.9634641
“Among them, the multi-phase inverters (MPIs) are the most representative, they have been widely used in motor drive systems [1], power generation systems [2], power transmission modules [3], and multiphase power supplies [4].”
BackgroundZhou, C., Zhang, Z., Su, J., Zhang, L., & Jing, G. (2024) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec60922.2024.10583480
Fault Diagnosis of Five-Phase Inverter Using One-Dimensional Convolutional Neural Network
Cui, B., & Cui, H. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-8828-6_32
Smart Fault Diagnosis in Grid Connected PV Systems: AI Methods Under Experimental Evaluation
Abidi, H., Belgacem, H., Sidhom, L., & Chihi, I. (2025) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon58223.2025.11221068
“These faults may result from environmental stressors such as temperature fluctuations, partial shading, soiling, and aging or from internal component failures involving converters, inverters, and sensors [3].”
Jadidi, S., & Liang, X. (2026) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2026.3653930
“A two-dimensional normalized fault vector for real-time diagnosis in five-leg VSIs is proposed in [8], but only focuses on single-switch and open-phase faults.”
Fadhel, S. (2020) · theses.fr (ABES) · doi:10.70675/254b1d32z31baz41bfzbf77z767e7777db4e · Cited by 3
Liu, Z. (2021) · theses.fr (ABES) · doi:10.70675/13fc3dfcz95b9z4d7czb141ze86067e11be4 · Cited by 1
Metadata
- Authors
- Trabelsi, M., Semail, E., & Nguyen, N. K.
- Affiliations
- Arts et Métiers (FR)
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2018-03
- Volume
- 6
- Issue
- 1
- Pages
- 339-351
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2723575887
- Cited by
- 61
- References
- 29
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 9 · 2023: 5 · 2022: 8 · 2021: 8 · 2020: 12 · 2019: 8 · 2018: 2
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE Journal of Emerging and Selected Topics in Power Electronics (publishedVersion)
- HAL (submittedVersion, other-oa)
- HAL (submittedVersion)
- LillOA (Université de Lille (University Of Lille)) (submittedVersion, other-oa)
- SAM, the Arts et Métiers ParisTech open access repository (Paris Institute of Technology) (submittedVersion, other-oa)
- Funders
- FEDER and Hauts-de-France region for the CE2I Project
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- inverter fault diagnosis, open-switch fault, open-phase fault, five-phase permanent magnet synchronous machine, multiphase machines, fault detection and identification, real-time fault diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.