Practical Analytical Model and Comprehensive Comparison of Power Loss Performance for Various MMCs Based on IGCT in HVDC Application
Open accessThe DOI matches its Crossref record.
Abstract
This paper gives a comprehensive analysis and characterization of power loss of a high-power integrated gate-commutated thyristor (IGCT) in a modular multilevel converter (MMC) for a high voltage dc application. The practical scheme, power loss models, calculation methods, characterization of MMC based on IGCT are analyzed in detail. Especially, a comprehensive comparison of both half-bridge MMC (HB-MMC) and full-bridge MMC (FB-MMC) based on IGCT, press-pack insulated gate bipolar transistor (IGBT), module-type IGBT, press-pack injection enhanced gate transistor (IEGT), and module-type IEGT is analyzed in this paper. According to the study in this paper, the snubber power loss of MMC based on IGCT is far less than the conduction and switching power losses. Both the conduction and switching power losses of IGCT are always lower than that of press-pack and module-type IGBTs and IEGTs in MMC. The power loss of FB-MMC is higher than that of HB-MMC with the same transmission power because more switches are employed in FB-MMC. If taking diodes into account, the HB-MMC and FB-MMC based on IGCT can decrease power loss about 1.9%-49.3% and 8.3%-45.1% under different operation states, respectively. The study in this paper will provide a valuable reference and promote the application of IGCT in MMC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zeng, R., Zhao, B., Wei, T., Xu, C., Chen, Z., Liu, J., Zhou, W., Song, Q., & Yu, Z. (2019) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2906952 · Cited by 65
“As for high-voltage large-capacity MMCs with multilevel schemes, the output multilevel voltage has a good sinusoidal property by a cascaded connection with hundreds of submodules, which suggests the use of low switching frequency to achieve good harmonic characteristics [19], [20].”
BackgroundSelf-citationDe Kooning, J. D. M., Stockman, K., De Maeyer, J., Jarquin-Laguna, A., & Vandevelde, L. (2021) · Processes · doi:10.3390/pr9122224 · Cited by 57
“Models were presented for determining the conduction and switching losses in [130] for the IGBT and in [131] for the IGCT.”
MethodIslam, M. M., Rahman, M. A., & Islam, M. R. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.3000596 · Cited by 16
Metadata
- Authors
- Zhao, B., Zeng, R., Li, J., Wei, T., Chen, Z., Song, Q., & Yu, Z.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2019-06
- Volume
- 7
- Issue
- 2
- Pages
- 1071-1083
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2891070354
- Cited by
- 53
- References
- 0
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practical Analytical Model and Comprehensive Comparison of Power Loss Performance for Various MMCs Based on IGCT in HVDC Application. https://app.cochat.ai/papers/10.1109/jestpe.2018.2871191
- The paper
- Zhao, B., Zeng, R., Li, J., Wei, T., Chen, Z., Song, Q., & Yu, Z. (2019). Practical Analytical Model and Comprehensive Comparison of Power Loss Performance for Various MMCs Based on IGCT in HVDC Application. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/jestpe.2018.2871191
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.