MoS2 Functionalized Multicore Fiber Probes for Selective Detection of Shigella Bacteria Based on Localized Plasmon
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Present study demonstrates the fiber-optic localized surface plasmon resonance (LSPR) based sensitive biosensor for detection of Shigella bacterial species. The proposed sensor is comprised of multi-core fiber (MCF) having seven cores arranged in a hexagonal shape and spliced with single-mode fiber (SMF) for efficient detection. An increase in evanescent waves (EWs) and coupling of modes between MCF cores was achieved by etching process in a controlled manner. The etching process also increases the refractive index sensitivity (RIS) of the proposed sensor. Further, coating with nanomaterials like gold nanoparticles (AuNPs) and molybdenum disulfide (MoS2) helps in the excitation of localized plasmons. Here, Shigella specific oligonucleotide probes are used as a recognition element. The results demonstrate that the proposed sensor can successfully and efficiently detect the Shigella bacterial species with high sensitivity. Shigella in the range of 10 - 100 CFU/mL (colony-forming unit/mL) can cause serious intestinal infection and therefore, its detection in this range is critical. The proposed sensor demonstrates a linearity range from 1 to 109CFU/mL with a detection time of 5 min and a limit of detection (LoD) of 1.56 CFU/mL. The proposed sensing methodology can be a potential alternative to the commercially existing ones in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A study of the nucleation and growth processes in the synthesis of colloidal gold
Turkevich, J., Stevenson, P. C., & Hillier, J. (1951) · Discussions of the Faraday Society · doi:10.1039/df9511100055 · Cited by 7,792 · cited 2×
“the concentration of tri-sodium citrate [33].”
MethodGold nanoparticle-enabled biological and chemical detection and analysis
Jans, H., & Huo, Q. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15280g · Cited by 725
Graphene–MoS2 hybrid nanostructures enhanced surface plasmon resonance biosensors
Zeng, S., Hu, S., Xia, J., Anderson, T., Dinh, X.-Q., Meng, X.-M., Coquet, P., & Yong, K.-T. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.10.124 · Cited by 461 · cited 1×
“interaction that has drawn the interest of scientific community for application in biosensing [15] and lower full width at half maximum [16].”
BackgroundKaushik, S., Tiwari, U. K., Pal, S. S., & Sinha, R. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.11.006 · Cited by 212 · cited 4×
“Various nanoparticles like gold nanoparticles (AuNPs), and molybdenum disulfide (MoS2) have been frequently used for the biosensing application [14].”
BackgroundMethodInfluentialSingh, R., Kumar, S., Liu, F., Cheng, S., Zhang, B., Jha, R., & Kaushik, B. K. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112557 · Cited by 160 · cited 2×
“earlier experimental data, this size of AuNPs is more sensitive for detection of living organisms [22].”
BackgroundSelf-citationKumar, S., Singh, R., Yang, Q., Cheng, S., Zhang, B., & Kaushik, B. K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2973579 · Cited by 85
Self-citationAgrawal, N., Saha, C. P., Kumar, C., Singh, R., Zhang, B., Jha, R., & Kumar, S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2997690 · Cited by 76 · cited 1×
“real-time response, economical, disposable, and simple to implement [10]–[13].”
BackgroundSelf-citationDuan, L. N., Zhang, P., Tang, M., Wang, R., Zhao, Z., Fu, S., Gan, L., Zhu, B., Tong, W., Liu, D., et al. (2016) · Optics Express · doi:10.1364/oe.24.020210 · Cited by 64 · cited 1×
“[22], shape [23], vibration [24], [25], twist [26], temperature [18], [27], strain [28], and bending [29], [30].”
BackgroundReal-time PCR using SYBR Green for the detection of Shigella spp. in food and stool samples
Mokhtari, W., Nsaibia, S., Gharbi, A., & Aouni, M. (2012) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2012.09.002 · Cited by 43 · cited 1×
“Several methods like loop-mediated amplification technique, PCR, and voltage-controlled signal amplification techniques are available for detection of Shigella species [1], [4], [38], [39].”
MethodSharma, P., Semwal, V., & Gupta, B. D. (2019) · Optical Fiber Technology · doi:10.1016/j.yofte.2019.101962 · Cited by 35 · cited 1×
“principle of LSPR phenomena that states that absorbance value changes due to the variation in the RI surrounding the sensor probe [35].”
Background
Cited by
2D material assisted SMF-MCF-MMF-SMF based LSPR sensor for creatinine detection
Li, M., Singh, R., Marques, C., Zhang, B., & Kumar, S. (2021) · Optics Express · doi:10.1364/oe.445555 · Cited by 176
Self-citationPathak, A. K., & Viphavakit, C. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113455 · Cited by 159
Recent Advancements of LSPR Fiber‐Optic Biosensing: Combination Methods, Structure, and Prospects
Zhang, H., Zhou, X., Li, X., Gong, P., Zhang, Y., & Zhao, Y. (2023) · Biosensors · doi:10.3390/bios13030405 · Cited by 99
“Generally speaking, to increase the strength of the evanescent field, it is necessary to perform hydrofluoric acid etching on the MCF [98] to increase the core area to realize mode coupling or to use the taper processing method to increase the field strength of the evanescent field.”
BackgroundMethodInfluential
Metadata
- Authors
- Kumar, S., Guo, Z., Singh, R., Wang, Q., Zhang, B., Cheng, S., Liu, F.-Z., Marques, C., Kaushik, B. K., & Jha, R.
- Venue
- Journal of Lightwave Technology
- Published
- 2021-06-15
- Volume
- 39
- Issue
- 12
- Pages
- 4069-4081
- ISSN
- 0733-8724 (ISSN-L)
- 1558-2213
- OpenAlex
- W3100292492
- Cited by
- 193
- References
- 13
- FWCI
- 12.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.