The DOI matches its Crossref record.
Design and fabrication of microfluidic devices for multiphase mixing and reaction
Abstract
Using silicon microfabrication technology, microchemical devices have been constructed for the purpose of conducting heterogeneously catalyzed multiphase reactions. The motivation behind the design, the fabrication approach, and the experimental characterization are presented for two classes of devices. The first design involves multiple parallel channels with integrated filter structures to incorporate standard catalytic materials. These catalysts are in the form of finely divided porous particles in a packed-bed arrangement. The second device involves the incorporation of porous silicon as a catalyst support, in the form of a thin layer covering microstructured channels. These microstructured channels simulate the structure of a packed bed and enhance mass transfer relative to an open channel. The ability to incorporate features at the tens-of-microns scale can reduce the mass-transfer limitations by promoting mixing and dispersion for the multiple phases. Directly integrating the catalyst support structures into the channels of the microreactor allows the precise definition of the bed properties, including the support's size, shape and arrangement, and the void fraction. Such a design would find broad applicability in enhancing the transport and active surface area for sensing, chemical, and biochemical conversion devices. Reaction rates for the gas-liquid-solid hydrogenation of cyclohexene using the integrated catalyst with porous silicon as a support compare favorably to those rates obtained with the packed-bed approach. In both cases, the mass transfer coefficient is at least 100 times better than conventional laboratory reactors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Self-citationA Microfluidic Device for Conducting Gas-Liquid-Solid Hydrogenation Reactions
Kobayashi, J., Mori, Y., Okamoto, K., Akiyama, R., Ueno, M., Kitamori, T., & Kobayashi, S. (2004) · Science · doi:10.1126/science.1096956 · Cited by 576
Shestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Microchemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Self-citation
Metadata
- Authors
- Losey, M. W., Jackman, R. J., Firebaugh, S. L., Schmidt, M. A., & Jensen, K. F.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2002-12
- Volume
- 11
- Issue
- 6
- Pages
- 709-717
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2101584978
- Cited by
- 232
- References
- 0
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and fabrication of microfluidic devices for multiphase mixing and reaction. https://app.cochat.ai/papers/10.1109/jmems.2002.803416
- The paper
- Losey, M. W., Jackman, R. J., Firebaugh, S. L., Schmidt, M. A., & Jensen, K. F. (2002). Design and fabrication of microfluidic devices for multiphase mixing and reaction. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2002.803416
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.