Electronically controllable microvalves based on smart hydrogels: Magnitudes and potential applications
Abstract
Electronically controllable microvalves based on temperature sensitive hydrogels as actuators are described. A thermal-electronic interface was used for electronic control of the liquid flow. The hydrogel actuators were directly placed in a flow channel. They used the process medium as the swelling agent. Because of the direct placement into the channel the elastic properties of the hydrogel actuator were utilized to improve the pressure insensitivity, to achieve high particle tolerance and to avoid a leakage flow. The microvalves show an extremely simple structure. They can be fabricated using conventional micro technology within a few technical steps. The microvalves can also be miniaturized to a currently unrivalled extent of about 4 μm×4 μm×1μm. Valves for "laboratory on chip" applications can already be obtained. The switching times of the electronically controllable microvalves based on hydrogels are 0.3 s to 10 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Smart polymers: Physical forms and bioengineering applications
Kumar, A., Srivastava, A., Galaev, I. Y., & Mattiasson, B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.003 · Cited by 742
Review on Hydrogel-based pH Sensors and Microsensors
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008) · Sensors · doi:10.3390/s8010561 · Cited by 742
Self-citationSmart polymeric gels: Redefining the limits of biomedical devices
Chaterji, S., Kwon, I. K., & Park, K. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.018 · Cited by 615
Cellulose-based hydrogel materials: chemistry, properties and their prospective applications
Kabir, S. M. F., Sikdar, P. P., Haque, B., Bhuiyan, M. A. R., Ali, A., & Islam, M. N. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0095-0 · Cited by 565
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
Biomimetic Hydrogel‐Based Actuating Systems
Ionov, L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203692 · Cited by 469
Hydrogel-based devices for biomedical applications
Deligkaris, K., Tadele, T. S., Olthuis, W., & van den Berg, A. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.03.083 · Cited by 451
Döring, A., Birnbaum, W., & Kuckling, D. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60031a · Cited by 391
Self-citationOptoelectrothermic Control of Highly Integrated Polymer‐Based MEMS Applied in an Artificial Skin
Richter, A., & Paschew, G. (2009) · Advanced Materials · doi:10.1002/adma.200802737 · Cited by 74
Self-citation
Metadata
- Authors
- Richter, A., Kuckling, D., Howitz, S., Gehring, T., & Arndt, K.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2003-10
- Volume
- 12
- Issue
- 5
- Pages
- 748-753
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2117504176
- Cited by
- 187
- References
- 0
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.