Abstract
Silicon atomic force microscope (AFM) cantilevers having integrated solid-state heaters were originally developed for application to data storage, but have since been applied to metrology, thermophysical property measurements, and nanoscale manufacturing. These applications beyond data storage have strict requirements for mechanical characterization and precise temperature calibration of the cantilever. This paper describes detailed mechanical, electrical, and thermal characterization and calibration of AFM cantilevers having integrated solid-state heaters. Analysis of the cantilever response to electrical excitation in both time and frequency domains aids in resolving heat transfer mechanisms in the cantilever. Raman spectroscopy provides local temperature measurement along the cantilever with resolution near 1 mum and 5degC and also provides local surface stress measurements. Observation of the cantilever mechanical thermal noise spectrum at room temperature and while heated provides insight into cantilever mechanical behavior and compares well with finite-element analysis. The characterization and calibration methodology reported here expands the use of heated AFM cantilevers, particularly the uses for nanomanufacturing and sensing
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Siemens, M. E., Li, Q., Yang, R., Nelson, K. A., Anderson, E. H., Murnane, M. M., & Kapteyn, H. C. (2010) · Nature Materials · doi:10.1038/nmat2568 · Cited by 443
Metadata
- Authors
- Lee, J., Beechem, T., Wright, T. L., Nelson, B. A., Graham, S., & King, W. P.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2006-12
- Volume
- 15
- Issue
- 6
- Pages
- 1644-1655
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2143198442
- Cited by
- 209
- References
- 0
- FWCI
- 25.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.