The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Characterization of Nontoxic Liquid-Metal Alloy Galinstan for Applications in Microdevices
Open accessAbstract
We have obtained interfacial properties of Galinstan, a nontoxic liquid-metal alloy, to help replace mercury in miniature devices. To prevent formation of an oxide skin that severely hinders the fluidic behavior of small Galinstan droplets and leads to inaccurate property data, we performed our experiments in a nitrogen-filled glove box. It was found that only if never exposed to oxygen levels above 1 part per million (ppm) would Galinstan droplets behave like a liquid. Two key properties were then investigated: contact angles and surface tension. Advancing and receding contact angles of Galinstan were measured from sessile droplets on various materials: for example, 146.8$^{\circ}$and 121.5$^{\circ}$, respectively, on glass. Surface tension was measured by the pendant-drop method to be 534.6$\pm$10.7 mN/m. All the measurements were done in nitrogen at 28$^{\circ}\hbox{C}$with oxygen and moisture levels below 0.5 ppm. To help design droplet-based microfluidic devices, we tested the response of Galinstan to electrowetting-on-dielectric actuation.$\hfill$[2011-0124]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Cited by
Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring
Gao, Y., Ota, H., Schaler, E. W., Chen, K., Zhao, A., Gao, W., Fahad, H. M., Leng, Y., Zheng, A., Xiong, F., et al. (2017) · Advanced Materials · doi:10.1002/adma.201701985 · Cited by 614
Stretchable Active Matrix Temperature Sensor Array of Polyaniline Nanofibers for Electronic Skin
Hong, S. Y., Lee, Y. H., Park, H., Jin, S. W., Jeong, Y. R., Yun, J., You, I., Zi, G., & Ha, J. S. (2016) · Advanced Materials · doi:10.1002/adma.201504659 · Cited by 454
Tang, J., Zhao, X., Li, J., Guo, R., Zhou, Y., & Liu, J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b10256 · Cited by 357
Methods to pattern liquid metals
Joshipura, I. D., Ayers, H. R., Majidi, C., & Dickey, M. D. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00330j · Cited by 326
Wafer-scale two-dimensional semiconductors from printed oxide skin of liquid metals
Carey, B. J., Ou, J. Z., Clark, R. M., Berean, K. J., Zavabeti, A., Chesman, A. S. R., Russo, S. P., Lau, D. W. M., Xu, Z.-Q., Bao, Q., et al. (2017) · Nature Communications · doi:10.1038/ncomms14482 · Cited by 292
Metadata
- Authors
- Liu, T., Sen, P., & Kim, C.-J.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2012-04
- Volume
- 21
- Issue
- 2
- Pages
- 443-450
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2092638653
- Cited by
- 719
- References
- 1
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Nontoxic Liquid-Metal Alloy Galinstan for Applications in Microdevices. https://app.cochat.ai/papers/10.1109/jmems.2011.2174421
- The paper
- Liu, T., Sen, P., & Kim, C.-J. (2012). Characterization of Nontoxic Liquid-Metal Alloy Galinstan for Applications in Microdevices. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2011.2174421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.