Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A Microfabricated Wireless RF Pressure Sensor Made Completely of Biodegradable Materials

Luo, Mengdi, Martinez, Adam W., Song, Chao, Herrault, Florian, Allen, Mark G.·2014·Journal of Microelectromechanical Systems

Abstract

A wireless RF MEMS pressure sensor made entirely of biodegradable materials is presented. Such biodegradable sensors may be appropriate for short-term, acute medical implantation applications as they potentially eliminate the need for implant extraction when sensing is no longer required. The biodegradable sensors described here require structural materials for pressure sensing, dielectric materials for insulation, and conducting materials for formation of electrical elements and wireless links. Zinc/iron bilayers were used as the sensor conductor material, and known biodegradable polymers poly-L-lactide and polycaprolactone were used as dielectric and structural materials. Zinc, which otherwise degrades very slowly on its own under biological conditions, is galvanically activated when electrically connected to iron in saline, greatly increasing the total degradation rate of the conductors. To avoid contact of the biodegradable materials with the strong chemicals or solvents that are typically used in conventional MEMS fabrication, embossing, multilayer folding, and lamination were combined with traditional techniques during fabrication. The fabricated sensor was wirelessly tested in both air and 0.9% saline and demonstrated a linear frequency response with external applied pressure. A sensitivity of 39 kHz/kPa was measured in the 0-20 kPa pressure range in air and initially in saline. After immersion in saline for 20 h, the sensor stabilized, remaining stable and functional for 86 h with a sensitivity of -54±4 kHz/kPa.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2013.2290111

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • A Physically Transient Form of Silicon Electronics

    Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286 · cited 1×

    “Example platforms including transistors, diodes, inductors, capacitors, resistors and interconnects [15].”
  • Cracking in polylactide spherulites

    Fraschini, C., Plesu, R., Sarasua, J., & Prud'homme, R. E. (2005) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.20616 · Cited by 37 · cited 1×

    “Since PLLA shows brittle behavior at room temperatures [42, 43], the formation of cracks is not unexpected as a”

Show all 2 references

Cited by

See all 170

Metadata

Authors
Luo, M., Martinez, A. W., Song, C., Herrault, F., & Allen, M. G.
Venue
Journal of Microelectromechanical Systems
Published
2014-02
Volume
23
Issue
1
Pages
4-13
ISSN
  • 1057-7157 (ISSN-L)
  • 1941-0158
OpenAlex
W2075711942
Cited by
170
References
2
FWCI
6.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Microfabricated Wireless RF Pressure Sensor Made Completely of Biodegradable Materials. https://app.cochat.ai/papers/10.1109/jmems.2013.2290111
The paper
Luo, M., Martinez, A. W., Song, C., Herrault, F., & Allen, M. G. (2014). A Microfabricated Wireless RF Pressure Sensor Made Completely of Biodegradable Materials. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2013.2290111

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.