The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
A Physically Transient Form of Silicon Electronics
Open accessAbstract
Reversible Implants: Silicon electronics are generally designed to be stable and robust—it would be counterproductive if the key parts of your computer or cell phone slowly dissolved away while you were using it. In order to develop transient electronics for use as medical implants, Hwang et al. (p. 1640 , see the cover) produced a complete set of tools and materials that would be needed to make standard devices. Devices were designed to have a specific lifetime, after which the component materials, such as porous silicon and silk, would be resorbed by the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“For applications where the functions of the implants are only necessary for a predefined period of time, this class of so-called transient electronics employ a layered design (Hwang et al., 2012) where degradable polymeric materials act as an encapsulation layer, with functional inorganic materials such as zinc, magnesium, or silicon enclosed inside.”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Hwang et al., 2012
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationBlock, G., Hulbert-Shearon, T., Levin, N., & Port, F. (1998) · American Journal of Kidney Diseases · doi:10.1053/ajkd.1998.v31.pm9531176 · Cited by 2,354
Biodegradable luminescent porous silicon nanoparticles for in vivo applications
Park, J.-H., Gu, L., von Maltzahn, G., Ruoslahti, E., Bhatia, S. N., & Sailor, M. J. (2009) · Nature Materials · doi:10.1038/nmat2398 · Cited by 1,897
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Self-citationSeidel, H., Csepregi, L., Heuberger, A., & Baumgärtel, H. (1990) · Journal of The Electrochemical Society · doi:10.1149/1.2086277 · Cited by 1,633
The kinetics of silica-water reactions
Rimstidt, J. D., & Barnes, H. L. (1980) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(80)90220-3 · Cited by 1,266
Growth of native oxide on a silicon surface
Morita, M., Ohmi, T., Hasegawa, E., Kawakami, M., & Ohwada, M. (1990) · Journal of Applied Physics · doi:10.1063/1.347181 · Cited by 914
In vivo degradation of three-dimensional silk fibroin scaffolds
Wang, Y., Rudym, D. D., Walsh, A., Abrahamsen, L., Kim, H.-J., Kim, H. S., Kirker-Head, C., & Kaplan, D. L. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.002 · Cited by 789
Self-citationLevine, R. D. (2005) · Cambridge University Press eBooks · doi:10.1017/cbo9780511614125 · Cited by 709
Research works printed but not linked: 2
- Becker W., et al.., European Food Safety Authority 60, 1 (2004).
- V. R. Young et al . Dietary Reference Intakes for Calcium Phosphorus Magnesium Vitamin D and Fluoride (National Academies Press Washington DC 1997).
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Self-citationPEDOT:PSS for Flexible and Stretchable Electronics: Modifications, Strategies, and Applications
Fan, X., Nie, W., Tsai, H., Wang, N., Huang, H., Cheng, Y., Wen, R., Ma, L., Yan, F., & Xia, Y. (2019) · Advanced Science · doi:10.1002/advs.201900813 · Cited by 1,028
Metadata
- Authors
- Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., Song, Y. M., Yu, K. J., Ameen, A., Li, R., Su, Y., Yang, M., Kaplan, D. L., Zakin, M. R., Slepian, M. J., Huang, Y., Omenetto, F. G., & Rogers, J. A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Tufts University (US)
- Seoul National University (KR)
- Northwestern University (US)
- Nano Terra (United States) (US)
- University of Arizona (US)
- Corresponding author
- Hwang, Suk-Won
- Tao, Hu
- Kim, Dae-Hyeong
- Omenetto, Fiorenzo G.
- Rogers, John A.
- ORCID
- Venue
- Science
- Published
- 2012-09-28
- Volume
- 337
- Issue
- 6102
- Pages
- 1640-1644
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC3786576
- OpenAlex
- W2044815207
- Cited by
- 1,286
- References
- 33
- Citations by year
- 2026: 65 · 2025: 69 · 2024: 101 · 2023: 101 · 2022: 93 · 2021: 111 · 2020: 126 · 2019: 103 · 2018: 127 · 2017: 88 · 2016: 93 · 2015: 83 · 2014: 79 · 2013: 38 · 2012: 8
- FWCI
- 42.51
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (EB-002520, P41EB002520)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Thin-Film Transistor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Semiconductor materials and devices
- Keywords
- transient electronics, silicon electronics, CMOS, biomedical implants, biodegradable electronics, wireless control, integrated sensors and actuators, power supply systems
- MeSH terms
- Animals, Anti-Bacterial Agents, Electronics, Metals, Mice, Inbred BALB C, Oxides, Electric Power Supplies, Semiconductors, Silicon, Transistors, Electronic, Absorbable Implants, Mice, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Physically Transient Form of Silicon Electronics. https://app.cochat.ai/papers/10.1126/science.1226325
- The paper
- Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., Song, Y. M., Yu, K. J., Ameen, A., Li, R., Su, Y., Yang, M., Kaplan, D. L., Zakin, M. R., Slepian, M. J., . . . Rogers, J. A. (2012). A Physically Transient Form of Silicon Electronics. Science. https://doi.org/10.1126/science.1226325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.