Powering a Ventricular Assist Device (VAD) With the Free-Range Resonant Electrical Energy Delivery (FREE-D) System
Abstract
Wireless data communication technology has eliminated wired connections for data transfer to portable devices. Wireless power technology offers the possibility of eliminating the remaining wired connection: the power cord. For ventricular assist devices (VADs), wireless power technology will eliminate the complications and infections caused by the percutaneous wired power connection. Integrating wireless power technology into VADs will enable VAD implants to become a more viable option for heart failure patients (of which there are 80 000 in the United States each year) than heart transplants. Previous transcutaneous energy transfer systems (TETS) have attempted to wirelessly power VADs ; however, TETS-based technologies are limited in range to a few millimeters, do not tolerate angular misalignment, and suffer from poor efficiency. The free-range resonant electrical delivery (FREE-D) wireless power system aims to use magnetically coupled resonators to efficiently transfer power across a distance to a VAD implanted in the human body, and to provide robustness to geometric changes. Multiple resonator configurations are implemented to improve the range and efficiency of wireless power transmission to both a commercially available axial pump and a VentrAssist centrifugal pump [3]. An adaptive frequency tuning method allows for maximum power transfer efficiency for nearly any angular orientation over a range of separation distances. Additionally, laboratory results show the continuous operation of both pumps using the FREE-D system with a wireless power transfer efficiency upwards of 90%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because quasi-static (nonradiative) magnetic fields mediate coupling, energy transfer through tissue is not substantially different from that in free space (20).”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [20]
Citations
Cites
Sample, A. P., Meyer, D. A., & Smith, J. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046002 · Cited by 1,808
Self-citationUse of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist Device
Pagani, F. D., Miller, L. W., Russell, S. D., Aaronson, K. D., John, R., Boyle, A. J., Conte, J. V., Bogaev, R. C., MacGillivray, T. E., Naka, Y., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.055 · Cited by 869
Prevention of infective endocarditis: Guidelines from the American Heart Association
Wilson, W., Taubert, K. A., Gewitz, M., Lockhart, P. B., Baddour, L. M., Levison, M., Bolger, A., Cabell, C. H., Takahashi, M., Baltimore, R. S., et al. (2008) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2008.0346 · Cited by 484
Deng, M. C., Edwards, L. B., Hertz, M. I., Rowe, A. W., Keck, B. M., Kormos, R., Naftel, D. C., Kirklin, J. K., & Taylor, D. O. (2005) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2005.07.002 · Cited by 348
Topkara, V. K., Kondareddy, S., Malik, F., Wang, I.-W., Mann, D. L., Ewald, G. A., & Moazami, N. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.04.093 · Cited by 281
Zierer, A., Melby, S. J., Voeller, R. K., Guthrie, T. J., Ewald, G. A., Shelton, K., Pasque, M. K., Moon, M. R., Damiano, R. J., & Moazami, N. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.03.085 · Cited by 206
Ventricular assist device-related infections
Gordon, R. J., Quagliarello, B., & Lowy, F. D. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70522-9 · Cited by 175
Deng, M. C.-H. K. (2003) · Current Opinion in Cardiology · doi:10.1097/00001573-200303000-00014 · Cited by 132
Allen, J. G., Weiss, E. S., Schaffer, J. M., Patel, N. D., Ullrich, S. L., Russell, S. D., Shah, A. S., & Conte, J. V. (2009) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2009.07.017 · Cited by 120
Obesity and Left Ventricular Assist Device Driveline Exit Site Infection
Raymond, A. L., Kfoury, A. G., Bishop, C. J., et al. (2010) · ASAIO Journal · doi:10.1097/mat.0b013e3181c879b1 · Cited by 110
Monkowski, D., Axelrod, P. I., Fekete, T., et al. (2007) · Transplant Infectious Disease · doi:10.1111/j.1399-3062.2006.00185.x · Cited by 103
El‐Banayosy, A., Arusoglu, L., Kizner, L., et al. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)04097-3 · Cited by 67
Midterm experience with the Jarvik 2000 axial flow left ventricular assist device
Haj‐Yahia, S., Birks, E. J., Rogers, P., et al. (2007) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.01.002 · Cited by 64
Martin, S. I., Wellington, L., Stevenson, K., et al. (2010) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2009.227801 · Cited by 46
Device Related Infections: Are We Making Progress?
Holman, W. L., Pamboukian, S. V., McGiffin, D. C., et al. (2010) · Journal of Cardiac Surgery · doi:10.1111/j.1540-8191.2010.01034.x · Cited by 42
Deng, M. C.-H. K., Edwards, L. B., Hertz, M. I., et al. (2003) · The Journal of Heart and Lung Transplantation · doi:10.1016/s1053-2498(03)00183-9 · Cited by 33
Functions for detecting malposition of transcutaneous energy transmission coils.
Ozeki, T., Chinzei, T., Abe, Y., et al. (2003) · PubMed · Cited by 18
Design and Analysis of A Class-E Frequency-Controlled Transcutaneous Energy Transfer System
Mizannojehdehi, A., Shams, M., & Mussivand, T. V. (2006) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2006.379671 · Cited by 12
Research works printed but not linked: 4
- 2010, VentrAssist LVAS Clinical Instructions for Use
- 2010, HeartMate II LVAS Operating Manual
- smith, 2011, Innovative free-range resonant electrical energy delivery system (FREE-D system) for a ventricular assist device (VAD) using wireless power, Proc ASAIO 31st Annu Conf, 102
- bonde, 2011, Wireless power for ventricular assist devices: Innovation with the free-range resonant electrical energy delivery system (FREE-D) for mechanical circulatory assist, Proc AATS 91st Annu Sci Meeting, 1
Cited by
A Critical Review of Recent Progress in Mid-Range Wireless Power Transfer
Hui, S. Y. R., Zhong, W., & Lee, C. K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2249670 · Cited by 1,465
Li, H., Li, J., Wang, K., Chen, W., & Yang, X. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2349534 · Cited by 592
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Lyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2852680 · Cited by 47
Metadata
- Authors
- Waters, B. H., Sample, A. P., Bonde, P., & Smith, J. R.
- Affiliations
- University of Washington (US)
- Yale University (US)
- Venue
- Proceedings of the IEEE
- Published
- 2012-01
- Volume
- 100
- Issue
- 1
- Pages
- 138-149
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2104473700
- Semantic Scholar
- c55de503457a7e50b3104f9cec469ddf0be7abe0
- Cited by
- 169
- References
- 19
- Citations by year
- 2026: 1 · 2024: 10 · 2023: 6 · 2022: 7 · 2021: 20 · 2020: 9 · 2019: 10 · 2018: 17 · 2017: 20 · 2016: 14 · 2015: 13 · 2014: 17 · 2013: 20 · 2012: 5
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proceedings of the IEEE (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Mechanical Circulatory Support Devices
- Keywords
- ventricular assist devices, wireless power transfer, transcutaneous energy transmission, magnetically coupled resonators, resonant inductive coupling, axial flow pump, centrifugal pump, heart failure, biomedical implants, angular misalignment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.