CoChat

Effect of group velocity mismatch on the measurement of ultrashort optical pulses via second harmonic generation

Weiner, A. · 1983 · IEEE Journal of Quantum Electronics
Cited by 171

The DOI matches its Crossref record.

Abstract

The use of second harmonic generation as a technique for optical pulse width measurements is analyzed to determine the effects of both phase velocity and group velocity mismatch between fundamental and second harmonic fields. An expression for the time average second harmonic energy, which except for special cases differs from the intensity autocorrelation function, is derived. For Type I phase matching, the measurement yields an apparent correlation width which can be either shorter or longer than the actual intensity correlation width, depending on the specific pulse shape. When the group velocity mismatch is nonzero, the measurement becomes sensitive to the phase matching condition. Two special pulse shapes for which the measurement is independent of group and phase velocity mismatch are the Gaussian and the single-sided exponential.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jqe.1983.1072036

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
Weiner, A.
Venue
IEEE Journal of Quantum Electronics
Published
1983-08
Volume
19
Issue
8
Pages
1276-1283
ISSN
0018-9197 (ISSN-L)
OpenAlex
W1964023180
Cited by
171
References
0
FWCI
1.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of group velocity mismatch on the measurement of ultrashort optical pulses via second harmonic generation. https://app.cochat.ai/papers/10.1109/jqe.1983.1072036
The paper
Weiner, A. (1983). Effect of group velocity mismatch on the measurement of ultrashort optical pulses via second harmonic generation. IEEE Journal of Quantum Electronics. https://doi.org/10.1109/jqe.1983.1072036

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.