Effect of group velocity mismatch on the measurement of ultrashort optical pulses via second harmonic generation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The use of second harmonic generation as a technique for optical pulse width measurements is analyzed to determine the effects of both phase velocity and group velocity mismatch between fundamental and second harmonic fields. An expression for the time average second harmonic energy, which except for special cases differs from the intensity autocorrelation function, is derived. For Type I phase matching, the measurement yields an apparent correlation width which can be either shorter or longer than the actual intensity correlation width, depending on the specific pulse shape. When the group velocity mismatch is nonzero, the measurement becomes sensitive to the phase matching condition. Two special pulse shapes for which the measurement is independent of group and phase velocity mismatch are the Gaussian and the single-sided exponential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generation of optical pulses shorter than 0.1 psec by colliding pulse mode locking
Fork, R. L., Greene, B. I., & Shank, C. V. (1981) · Applied Physics Letters · doi:10.1063/1.92500 · Cited by 886
Compression of femtosecond optical pulses
Shank, C. V., Fork, R. L., Yen, R. T., Stolen, R. H., & Tomlinson, W. J. (1982) · Applied Physics Letters · doi:10.1063/1.93276 · Cited by 469
Goodwin, D. W. (1973) · Optica Acta: International Journal of Optics · doi:10.1080/713818732 · Cited by 421
Zernike, F. (1964) · Journal of the Optical Society of America · doi:10.1364/josa.54.001215 · Cited by 289
Second-harmonic generation by picosecond optical pulses
Glenn, W. H. (1969) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1969.1081948 · Cited by 127
SECOND HARMONIC GENERATION FROM SHORT PULSES
Comly, J. C., & Garmire, E. (1968) · Applied Physics Letters · doi:10.1063/1.1651838 · Cited by 111
Cited by
Ultrafast Vibrational Dynamics of Hydrogen Bonds in the Condensed Phase
Nibbering, E. T. J., & Elsaesser, T. (2004) · Chemical Reviews · doi:10.1021/cr020694p · Cited by 600
Frequency-resolved optical gating with the use of second-harmonic generation
DeLong, K. W., Trebino, R., Hunter, J., & White, W. E. (1994) · Journal of the Optical Society of America B · doi:10.1364/josab.11.002206 · Cited by 433
Ranka, J. K., Gaeta, A. L., Baltuska, A., Pshenichnikov, M. S., & Wiersma, D. A. (1997) · Optics Letters · doi:10.1364/ol.22.001344 · Cited by 242
Imeshev, G., Arbore, M. A., Fejer, M. M., Galvanauskas, A., Fermann, M., & Harter, D. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.000304 · Cited by 177
Li, G., Chen, Y., Jiang, H., & Chen, X. (2017) · Optics Letters · doi:10.1364/ol.42.000939 · Cited by 75
Metadata
- Authors
- Weiner, A.
- Venue
- IEEE Journal of Quantum Electronics
- Published
- 1983-08
- Volume
- 19
- Issue
- 8
- Pages
- 1276-1283
- ISSN
- 0018-9197 (ISSN-L)
- OpenAlex
- W1964023180
- Cited by
- 171
- References
- 6
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.