The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Numerical Analysis of a Photonic Crystal Fiber for Biosensing Applications
Abstract
This paper presents a theoretical study on a photonic crystal fiber (PCF) surface plasmon resonance biosensor. The proposed PCF sensor introduces the concept of simultaneous detection with H E11xand H E11xmodes, which opens up some possibilities for multianalyte/multichannel sensing. Analysis was performed which considered the operation of the sensor in both amplitude and wavelength interrogation modes. Typical sensor resolutions of 4×10-5RIU and 8×10-5RIU with respect to H E11xand H E11y, respectively, are reported for the amplitude interrogation mode, while resoutions of 5 × 10-5RIU and 6×10-5RIU are reported for H E11xand H E11y, respectively, for the wavelength interrogation mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Surface plasmon resonance sensors: review
Homola, J., Yee, S. S., & Gauglitz, G. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(98)00321-9 · Cited by 5,453
A fiber-optic chemical sensor based on surface plasmon resonance
Jorgenson, R. C., & Yee, S. S. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)80021-3 · Cited by 1,229
Towards integrated and sensitive surface plasmon resonance biosensors: A review of recent progress
Hoa, X. D., Kirk, A. G., & Tabrizian, M. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.07.001 · Cited by 790
Microstructured Optical Fibers as High-Pressure Microfluidic Reactors
Sazio, P. J. A., Amezcua-Correa, A., Finlayson, C. E., Hayes, J. R., Scheidemantel, T. J., Baril, N. F., Jackson, B. R., Won, D.-J., Zhang, F., Margine, E. R., et al. (2006) · Science · doi:10.1126/science.1124281 · Cited by 528
Hassani, A., & Skorobogatiy, M. A. (2006) · Optics Express · doi:10.1364/oe.14.011616 · Cited by 451
Photonic bandgap fiber-based Surface Plasmon Resonance sensors
Gauvreau, B., Hassani, A., Fassi Fehri, M., Kabashin, A., & Skorobogatiy, M. A. (2007) · Optics Express · doi:10.1364/oe.15.011413 · Cited by 296
Dhawan, A., Gerhold, M. D., & Muth, J. F. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.923933 · Cited by 111
Cited by
Photonic crystal fiber based plasmonic sensors
Rifat, A. A., Ahmed, R., Yetisen, A. K., Butt, H., Sabouri, A., Mahdiraji, G. A., Yun, S. H., & Adikan, F. R. M. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.11.113 · Cited by 476
Graphene-Based Birefringent Photonic Crystal Fiber Sensor Using Surface Plasmon Resonance
Dash, J. N., & Jha, R. (2014) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2014.2315233 · Cited by 298
Metadata
- Authors
- Akowuah, E. K., Gorman, T., Ademgil, H., Haxha, S., Robinson, G. K., & Oliver, J. V.
- Venue
- IEEE Journal of Quantum Electronics
- Published
- 2012-11
- Volume
- 48
- Issue
- 11
- Pages
- 1403-1410
- ISSN
- 0018-9197 (ISSN-L)
- 1558-1713
- OpenAlex
- W1969948656
- Cited by
- 378
- References
- 8
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Numerical Analysis of a Photonic Crystal Fiber for Biosensing Applications. https://app.cochat.ai/papers/10.1109/jqe.2012.2213803
- The paper
- Akowuah, E. K., Gorman, T., Ademgil, H., Haxha, S., Robinson, G. K., & Oliver, J. V. (2012). Numerical Analysis of a Photonic Crystal Fiber for Biosensing Applications. IEEE Journal of Quantum Electronics. https://doi.org/10.1109/jqe.2012.2213803
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.