The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Silicon piezoresistive stress sensors and their application in electronic packaging
Abstract
Structural reliability of integrated circuit (IC) chips in electronic packages continues to be a major concern due to ever-increasing die size, circuit densities, power dissipation, operating temperatures, and the use of a wide range of low-cost packaging materials. A powerful method for experimental eval- uation of silicon die stress distributions is the use of test chips incorporating integral piezoresistive sensors. In this paper, a review is made of the state-of-the-art in the area of silicon piezore- sistive stress sensor test chips. Developments in sensor theory, calibration methods, and packaging applications are presented. In the absence of die failure, packaging-induced stresses result in changes in the parametric performance of circuitry on the die, and the theory discussed here can be used to predict such changes. Index Terms—Electronic packaging, piezoresistive, stress sensor, test chip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoresistance Effect in Germanium and Silicon
Smith, C. S. (1954) · Physical Review · doi:10.1103/physrev.94.42 · Cited by 2,036
A graphical representation of the piezoresistance coefficients in silicon
Kanda, Y. (1982) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1982.20659 · Cited by 907
Mobility Anisotropy and Piezoresistance in Silicon p-Type Inversion Layers
Colman, D., Bate, R. T., & Mize, J. P. (1968) · Journal of Applied Physics · doi:10.1063/1.1656464 · Cited by 198
Temperature Dependence of the Piezoresistance of High-Purity Silicon and Germanium
Morin, F. J., Geballe, T. H., & Herring, C. (1957) · Physical Review · doi:10.1103/physrev.105.525 · Cited by 185
Measurement of the Elastic Constants of Silicon Single Crystals and Their Thermal Coefficients
McSkimin, H. J., Bond, W. L., Buehler, E., & Teal, G. K. (1951) · Physical Review · doi:10.1103/physrev.83.1080 · Cited by 122
Jaeger, R. C., Suhling, J. C., & Ramani, R. (1994) · IEEE Transactions on Components Packaging and Manufacturing Technology Part B · doi:10.1109/96.296437 · Cited by 102
Self-citation
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Review: Semiconductor Piezoresistance for Microsystems
Barlian, A. A., Park, W.-T., Mallon, J. R., Rastegar, A. J., & Pruitt, B. L. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2013612 · Cited by 949
Mechanoluminescence Rebrightening the Prospects of Stress Sensing: A Review
Zhuang, Y., & Xie, R. (2021) · Advanced Materials · doi:10.1002/adma.202005925 · Cited by 507
Flexible Piezoelectric Acoustic Sensors and Machine Learning for Speech Processing
Jung, Y. H., Hong, S. K., Wang, H. S., Han, J. H., Pham, T. X., Park, H., Kim, J., Kang, S., Yoo, C. D., & Lee, K. J. (2020) · Advanced Materials · doi:10.1002/adma.201904020 · Cited by 338
Metadata
- Authors
- Suhling, J. C., & Jaeger, R. C.
- Venue
- IEEE Sensors Journal
- Published
- 2001-06
- Volume
- 1
- Issue
- 1
- Pages
- 14-30
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2112874751
- Cited by
- 281
- References
- 6
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Silicon piezoresistive stress sensors and their application in electronic packaging. https://app.cochat.ai/papers/10.1109/jsen.2001.923584
- The paper
- Suhling, J. C., & Jaeger, R. C. (2001). Silicon piezoresistive stress sensors and their application in electronic packaging. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2001.923584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.