The DOI matches its Crossref record.
Design and Fabrication of a Microimpedance Biosensor for Bacterial Detection
Abstract
A biosensor for bacterial detection was developed based on microelectromechanical systems, heterobifunctional crosslinkers and immobilized antibodies. The sensor detected the change in impedance caused by the presence of bacteria immobilized on interdigitated gold electrodes and was fabricated from (100) silicon with a 2-/spl mu/m layer of thermal oxide as an insulating layer. The sensor active area is 9.6 mm/sup 2/ and consists of two interdigital gold electrode arrays measuring 0.8 /spl times/ 6 mm. Escherichia coli specific antibodies were immobilized to the oxide between the electrodes to create a biological sensing surface. The impedance across the interdigital electrodes was measured after immersing the biosensor in solution. Bacteria cells present in the sample solution attached to the antibodies and became tethered to the electrode array, thereby causing a change in measured impedance. The biosensor was able to discriminate between different cellular concentrations from 10/sup 5/ to 10/sup 7/ CFU/mL in pure culture. The sample testing process, including data acquisition, required 5 min. The design, fabrication, and testing of the biosensor is discussed along with the implications of these findings toward further biosensor development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells
Varshney, M., & Li, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.001 · Cited by 360
Impedance spectroscopy: Over 35 years of electrochemical sensor optimization
Pejcic, B., & De Marco, R. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.04.025 · Cited by 270
Lei, K. F., Wu, M.-H., Hsu, C.-W., & Chen, Y.-D. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)16588-6 · Cited by 12
Metadata
- Authors
- Radke, S. M., Alocilja, E. C., Radke, S. M., & Alocilja, E. C.
- Venue
- IEEE Sensors Journal
- Published
- 2004-08
- Volume
- 4
- Issue
- 4
- Pages
- 434-440
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2138758415
- Cited by
- 247
- References
- 0
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Fabrication of a Microimpedance Biosensor for Bacterial Detection. https://app.cochat.ai/papers/10.1109/jsen.2004.830300
- The paper
- Radke, S. M., Alocilja, E. C., Radke, S. M., & Alocilja, E. C. (2004). Design and Fabrication of a Microimpedance Biosensor for Bacterial Detection. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2004.830300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.