Electrical Impedance Determination of Cancer Cell Viability in a 3-Dimensional Cell Culture Microfluidic Chip
Open accessAbstract
A technique of quantitative determination of cell viability in three-dimensional (3D) cell culture construct is proposed based on on-site electrical impedance measurement in a microfluidic chip. In vitro 3D cell culture has been interpreted for faithfully representation of the in vivo cellular responses in living tissues. However, monitoring of the cellular responses in 3D cell culture construct is normally time-consuming and labor-intensive. In this work, a microfluidic chip was developed and is capable of on-site determining cell viability in 3D construct without affecting the cellular behaviors. The chip mainly consisted of a culture chamber, in which a pair of vertical electrodes at its opposite sidewalls was embedded for measurement, and a fluidic channel for perfusion purpose. Cancer cells/agarose suspension was loaded into the culture chamber for 3D cell culture with perfusing anti-cancer drug in different concentrations (6, 12, 18, and 24 μg ml-1) for 2 days. Since higher drug concentration led to more cell damage or death, the total impedance magnitude of the culture construct was shown to be reasonably proportional to the cell viability. The proposed technique has a high potential to develop a fast and easy measurement compared with the conventional cellular analysis techniques.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Other researchers have used 3D cell-based electrochemical biosensors to quantify cancer cell resistance to drug compounds and to study cancer cell proliferation in the presence of anticancer drugs.
“Other researchers have used 3D cell-based electrochemical biosensors to quantify cancer cell resistance to drug compounds 78,95 and to study cancer cell proliferation in the presence of anticancer drugs. 94”
From Three-dimensional cell culture systems and their applications in drug discovery and cell-based biosensors (2014) · cites this paper as [95]
Cites
Electrochemical Methods: Fundamentals and Applications
de Rooij, M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,115 · see citing works
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027 · see citing works
Hydrogels as extracellular matrix mimics for 3D cell culture
Tibbitt, M. W., & Anseth, K. S. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22361 · Cited by 2,727 · see citing works
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,228 · see citing works
Single cell dielectric spectroscopy
Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G. (2006) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/40/1/s10 · Cited by 446 · see citing works
Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures
Ehret, R., Baumann, W., Brischwein, M., et al. (1997) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)89087-7 · Cited by 388 · see citing works
A high density microelectrode array biosensor for detection of E. coli O157:H7
Radke, S. M., & Alocilja, E. C. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.07.021 · Cited by 372 · see citing works
Impedimetric immunosensors—A review
Prodromidis, M. I. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2009.01.081 · Cited by 347 · see citing works
Sun, T. L., Jackson, S. J., Haycock, J. W., & MacNeil, S. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.12.021 · Cited by 309 · see citing works
Design and Fabrication of a Microimpedance Biosensor for Bacterial Detection
Radke, S. M., Alocilja, E. C., Radke, S. M., et al. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.830300 · Cited by 247 · see citing works
Microfluidic Systems for Diagnostic Applications: A Review
Lei, K. F. (2012) · SLAS TECHNOLOGY · doi:10.1177/2211068212454853 · Cited by 129 · see citing works
Self-citationWu, M., Urban, J. P. G., Cui, Z., & Cui, Z. F. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9597-y · Cited by 107 · see citing works
Self-citationEhret, R., Baumann, W., Brischwein, M., et al. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522485 · Cited by 106 · see citing works
Effect of Extracellular pH on Matrix Synthesis by Chondrocytes in 3D Agarose Gel
Wu, M., Urban, J. P. G., Cui, Z. F., Cui, Z., & Xu, X. (2007) · Biotechnology Progress · doi:10.1021/bp060024v · Cited by 100 · see citing works
Self-citationImpedance measurement for real time detection of neuronal cell death
Diemert, S., Dolga, A. M., Tobaben, S., Grohm, J., Pfeifer, S., Öxler, E.-M., & Culmsee, C. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.09.012 · Cited by 98 · see citing works
Varshney, M., & Li, Y. (2007) · Talanta · doi:10.1016/j.talanta.2007.06.027 · Cited by 90 · see citing works
Ma, K.-S., Zhou, H., Zoval, J. V., et al. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.04.038 · Cited by 85 · see citing works
Mishra, N. N., Retterer, S. T., Zieziulewicz, T. J., et al. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.01.011 · Cited by 76 · see citing works
Label-free and reversible immunosensor based upon an ac impedance interrogation protocol
Grant, S., Davis, F., Law, K. A., et al. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.01.003 · Cited by 68 · see citing works
Cui, Z., Xu, X., Trainor, N. B., Triffitt, J. T., Urban, J., & Tirlapur, U. K. (2007) · Toxicology in Vitro · doi:10.1016/j.tiv.2007.05.015 · Cited by 65 · see citing works
Saum, A. G. E., Cumming, R. H., & Rowell, F. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00129-2 · Cited by 64 · see citing works
Monitoring of yeast cell concentration using a micromachined impedance sensor
Krommenhoek, E. E., Gardeniers, H. J. G. E., Bomer, J. G., et al. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.09.028 · Cited by 58 · see citing works
Wu, M.-H., Chang, Y.-H., Liu, Y.-T., Chen, Y.-M., Wang, S.-S., Wang, H.-Y., Lai, C.-S., & Pan, T.-M. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.11.027 · Cited by 42 · see citing works
Self-citationThakur, M., Mergel, K., Weng, A., et al. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.03.024 · Cited by 41 · see citing works
Microelectrode array biosensor for the detection of Legionella pneumophila
Lei, K. F., & Leung, P. H. M. (2011) · Microelectronic Engineering · doi:10.1016/j.mee.2011.10.002 · Cited by 31 · see citing works
Self-citationWu, M., & Kuo, C.-Y. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9478-2 · Cited by 23 · see citing works
Self-citationWu, M., Wang, H., Liu, H.-L., et al. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9549-z · Cited by 23 · see citing works
Self-citationLei, K. F. (2011) · Measurement Science and Technology · doi:10.1088/0957-0233/22/10/105802 · Cited by 18 · see citing works
Self-citationLei, K. F., Wu, M., Liao, P.-Y., Chen, Y., & Pan, T.-M. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-011-0854-x · Cited by 16 · see citing works
Self-citationElectrical detection of sandwich immunoassay on indium tin oxide interdigitated electrodes
Lei, K. F. (2011) · Micro & Nano Letters · doi:10.1049/mnl.2011.0007 · Cited by 13 · see citing works
Self-citationLei, K. F., Wu, M., Hsu, C., & Lin, C.-Y. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)18036-9 · Cited by 4 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Edmondson, R., Broglie, J. J., Adcock, A. F., & Yang, L. (2014) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2014.573 · Cited by 2,515 · see citing works
Lei, K. F., Wu, M.-H., Hsu, C.-W., & Chen, Y.-D. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.07.031 · Cited by 111 · see citing works
Self-citationLiao, C.-J., Hsieh, C.-H., Wang, H.-M., Chou, W.-P., Chiu, T.-K., Chang, J.-H., Chao, A.-C., & Wu, M.-H. (2017) · RSC Advances · doi:10.1039/c7ra03663a · Cited by 20 · see citing works
Self-citation
- Authors
- Lei, K. F., Wu, M.-H., Hsu, C.-W., & Chen, Y.-D.
- Affiliations
- Chang Gung University (TW)
- Corresponding author
- Lei, Kin Fong
- Venue
- International Journal of Electrochemical Science
- Publisher
- Elsevier BV
- Published
- 2012-12
- Volume
- 7
- Issue
- 12
- Pages
- 12817-12828
- ISSN
- 1452-3981 (ISSN-L)
- OpenAlex
- W4382394022
- Cited by
- 12
- References
- 31
- Citations by year
- 2026: 1 · 2025: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2017: 2 · 2014: 1 · 2013: 3
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- International Journal of Electrochemical Science (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Ministry of Science and Technology, Taiwan (NSC101-2221-E-182-003-MY3)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- electrical impedance, cell viability, 3D cell culture, microfluidics, cancer cells, agarose, anticancer agents, drug concentration, impedance measurement, field monitoring, cell death
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review