Multiple sensors on pulsed eddy-current detection for 3-D subsurface crack assessment
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper proposes the use of multiple sensors in pulsed eddy-current detection for three-dimensional (3-D) subsurface flaw imaging. A normalization technique has been proposed to eliminate the characteristic variation among the Hall devices used in the probe and lift off effects. A principal component analysis-based feature extraction that provides orthogonal information for multiple sensor fusion has been introduced and investigated. Using the features of multiple projection coefficients, 3-D surface flaws can be measured and reconstructed. The experimental tests have illustrated that the proposed method has delivered more defect information than the conventional peak value and time for pulsed eddy-current sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Martinez, A. M., & Kak, A. C. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.908974 · Cited by 3,249
A feature extraction technique based on principal component analysis for pulsed Eddy current NDT
Sophian, A., Tian, G. Y., Taylor, D., & Rudlin, J. (2003) · NDT & E International · doi:10.1016/s0963-8695(02)00069-5 · Cited by 343 · cited 1×
“Besides, two parameters are not good enough to identify the locations and the characters of flaws [15]–[18].”
BackgroundSelf-citationElectromagnetic and Eddy Current NDT: A Review
Tian, G. Y., Sophian, A., TAYLOR, D. J., & Rudlin, J. (2001) · Insight - Non-Destructive Testing and Condition Monitoring · Cited by 151
Self-citation
Cited by
Ghidoni, S., Antonello, M., Nanni, L., & Menegatti, E. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.07.020 · Cited by 18
Metadata
- Authors
- Tian, G. Y., Sophian, A., Taylor, D., & Rudlin, J.
- Venue
- IEEE Sensors Journal
- Published
- 2005-02
- Volume
- 5
- Issue
- 1
- Pages
- 90-96
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2115578677
- Cited by
- 175
- References
- 3
- FWCI
- 17.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple sensors on pulsed eddy-current detection for 3-D subsurface crack assessment. https://app.cochat.ai/papers/10.1109/jsen.2004.839129
- The paper
- Tian, G. Y., Sophian, A., Taylor, D., & Rudlin, J. (2005). Multiple sensors on pulsed eddy-current detection for 3-D subsurface crack assessment. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2004.839129
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.