Mobile Human Airbag System for Fall Protection Using MEMS Sensors and Embedded SVM Classifier
Abstract
This paper introduces a mobile human airbag system designed for fall protection for the elderly. A Micro Inertial Measurement Unit ($\mu$IMU) of 56 mm$\,\times\,$23 mm$\,\times\,$15 mm in size is built. This unit consists of three dimensional MEMS accelerometers, gyroscopes, a Bluetooth module and a Micro Controller Unit (MCU). It records human motion information, and, through the analysis of falls using a high-speed camera, a lateral fall can be determined by gyro threshold. A human motion database that includes falls and other normal motions (walking, running, etc.) is set up. Using a support vector machine (SVM) training process, we can classify falls and other normal motions successfully with a SVM filter. Based on the SVM filter, an embedded digital signal processing (DSP) system is developed for real-time fall detection. In addition, a smart mechanical airbag deployment system is finalized. The response time for the mechanical trigger is 0.133 s, which allows enough time for compressed air to be released before a person falls to the ground. The integrated system is tested and the feasibility of the airbag system for real-time fall protection is demonstrated.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Airbag systems rely on wearable accelerometers and gyroscopes to trigger inflation when a fall is detected.
“These systems rely upon wearable accelerometers and gyroscopes to trigger the inflation of the airbag when a fall is detected.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [83]
The citation lists haven’t been fetched yet
References 9 · Cited by 162
- Authors
- Shi, G., Chan, C. S., Li, W. J., Leung, K.-S., Zou, Y., & Jin, Y.
- Affiliations
- Shenzhen University (CN)
- Chinese University of Hong Kong (HK)
- Venue
- IEEE Sensors Journal
- Published
- 2009-05
- Volume
- 9
- Issue
- 5
- Pages
- 495-503
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2089937542
- Cited by
- 162
- References
- 9
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 6 · 2023: 15 · 2022: 13 · 2021: 9 · 2020: 18 · 2019: 15 · 2018: 9 · 2017: 8 · 2016: 8 · 2015: 11 · 2014: 13 · 2013: 7 · 2012: 9
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Keywords
- fall detection, fall protection, older adults, micro inertial measurement unit, MEMS accelerometer, MEMS gyroscope, support vector machine, embedded DSP
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review