Textile-Based Electrogoniometers for Wearable Posture and Gesture Capture Systems
The DOI matches its Crossref record.
Abstract
This paper introduces a method for detecting joint angles by using piezoresistive strain sensitive materials, as carbon loaded rubbers are. Materials used can be screen-printed onto fabrics to provide garments with a sensing apparatus able to reconstruct human postures and gestures. The main differences between this approach and the previous ones, and the core of this work, is the rigorous proof that for small local curvatures of the layers the constituting electrogoniometers, the resistance depends only on the total curvature of the layers and not on the particular form that the sensor keeps in adherence with the human body. In this paper, we show that the hypothesis of small local curvature does not severely restrict the set of angles which can be detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Wearable Sensors for Monitoring Human Motion: A Review on Mechanisms, Materials, and Challenges
Homayounfar, S. Z., & Andrew, T. L. (2020) · SLAS TECHNOLOGY · doi:10.1177/2472630319891128 · Cited by 227
“Lorussi et al.(14) developed a textile-based goniometer through screen-printing a conductive elastomer (CE; a mixture of graphite and silicon rubber) on fabric in both single- and double-layer structures that was capable of direct measurement of joint angles and almost overcame sensitivity to positioning of the sensor…”
BackgroundSensor Evaluation for Wearable Strain Gauges in Neurological Rehabilitation
Giorgino, T., Tormene, P., Lorussi, F., De Rossi, D., & Quaglini, S. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2019584 · Cited by 100
“sors can be realized with similar CE technology and process [28].”
BackgroundSelf-citationWireless Support to Poststroke Rehabilitation: MyHeart's Neurological Rehabilitation Concept
Giorgino, T., Tormene, P., Maggioni, G., Pistarini, C., & Quaglini, S. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2028020 · Cited by 31
Metadata
- Authors
- Lorussi, F., Galatolo, S., & De Rossi, D. E.
- Venue
- IEEE Sensors Journal
- Published
- 2009-09
- Volume
- 9
- Issue
- 9
- Pages
- 1014-1024
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2101389040
- Cited by
- 36
- References
- 0
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Textile-Based Electrogoniometers for Wearable Posture and Gesture Capture Systems. https://app.cochat.ai/papers/10.1109/jsen.2009.2024867
- The paper
- Lorussi, F., Galatolo, S., & De Rossi, D. E. (2009). Textile-Based Electrogoniometers for Wearable Posture and Gesture Capture Systems. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2009.2024867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.