Cited by 100Context-Aware Activity Recognition SystemsAdvanced Sensor and Energy Harvesting MaterialsStroke Rehabilitation and Recovery

Sensor Evaluation for Wearable Strain Gauges in Neurological Rehabilitation

Giorgino, Toni, Tormene, Paolo, Lorussi, Federico, De Rossi, Danilo, Quaglini, Silvana·2009·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Conductive elastomers are a novel strain sensing technology which can be unobtrusively embedded into a garment's fabric, allowing a new type of sensorized cloths for motion analysis. A possible application for this technology is remote monitoring and control of motor rehabilitation exercises. The present work describes a sensorized shirt for upper limb posture recognition. Supervised learning techniques have been employed to compare classification models for the analysis of strains, simultaneously measured at multiple points of the shirt. The instantaneous position of the limb was classified into a finite set of predefined postures, and the movement was decomposed in an ordered sequence of discrete states. The amount of information given by the observation of each sensor during the execution of a specific exercise was quantitatively estimated by computing the information gain for each sensor, which in turn allows the data-driven optimization of the garment. Real-time feedback on exercise progress can also be provided by reconstructing the sequence of consecutive positions assumed by the limb.

Integrity signals

Registry

Crossref · 10.1109/tnsre.2009.2019584

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A project that was part of the myHeart initiative led to the development of a sensorized garment-based system to facilitate rehabilitation interventions in the home setting.

    “A project that was part of the myHeart initiative [97,98] led to the development of a sensorized garment-based system to facilitate rehabilitation interventions in the home setting.”

The citation lists haven’t been fetched yet

References 35 · Cited by 100

Authors
Giorgino, T., Tormene, P., Lorussi, F., De Rossi, D., & Quaglini, S.
Affiliations
  • University of Pavia (IT)
  • University of Pisa (IT)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2009-08
Volume
17
Issue
4
Pages
409-415
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2114680254
Cited by
100
References
35
Citations by year
2025: 2 · 2024: 3 · 2023: 4 · 2022: 2 · 2021: 4 · 2020: 7 · 2019: 10 · 2018: 7 · 2017: 8 · 2016: 12 · 2015: 12 · 2014: 13 · 2013: 2 · 2012: 8
FWCI
5.15
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
Keywords
conductive elastomers, wearable strain sensors, motor rehabilitation
MeSH terms
Clothing, Equipment Design, Humans, Nervous System Diseases, Posture, Sensitivity and Specificity, Transducers, Reproducibility of Results, Monitoring, Ambulatory, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review