Analyses of Triaxial Accelerometer Calibration Algorithms
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper proposes a calibration procedure in order to minimize the process time and cost. It relies on the suggestion of optimal positions, in which the calibration procedure takes place, and on position number optimization. Furthermore, this paper describes and compares three useful calibration algorithms applicable on triaxial accelerometer to determine its mathematical error model without a need to use an expensive and precise calibration means, which is commonly required. The sensor error model (SEM) of triaxial accelerometer consists of three scale-factor errors, three nonorthogonality angles, and three offsets. For purposes of calibration, two algorithms were tested—the Levenberg–Marquardt and the Thin-Shell algorithm. Both were then related to algorithm based on Matlab fminunc function to analyze their efficiency and results. The proposed calibration procedure and applied algorithms were experimentally verified on accelerometers available on market. We performed various analyses of proposed procedure and proved its capability to estimate the parameters of SEM without a need of precise calibration means, with minimum number of iteration, both saving time, workload, and costs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Monitors were calibrated49 and corrected for orientation50 using previously published methods”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [49]
In the citing paper
“Devices were calibrated and non-wear periods were detected using standard procedures.15,16”
Citations
Cites
Strapdown Inertial Navigation Technology
Titterton, D., & Weston, J. (2004) · Institution of Engineering and Technology eBooks · doi:10.1049/pbra017e · Cited by 3,348
Methods for Non-Linear Least Squares Problems
Madsen, K., Nielsen, H. B., & Tingleff, O. (1999) · Cited by 969
Methods for Non-Linear Least Squares Problems (2nd ed.)
Madsen, K., Nielsen, H. B., & Tingleff, O. (2004) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 640
Improved Computation for Levenberg–Marquardt Training
Wilamowski, B. M., & Yu, H. (2010) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2010.2045657 · Cited by 622
Inertial sensor technology trends
Barbour, N., & Schmidt, G. (2001) · IEEE Sensors Journal · doi:10.1109/7361.983473 · Cited by 588
A new multi-position calibration method for MEMS inertial navigation systems
Syed, Z. F., Aggarwal, P., Goodall, C., Niu, X., & El-Sheimy, N. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/7/016 · Cited by 386
Calibration of a MEMS inertial measurement unit
Skog, I., & Händel, P. (2006) · Cited by 223
Calibration and data fusion solution for the miniature attitude and heading reference system
Jurman, D., Jankovec, M., Kamnik, R., & Topič, M. (2007) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.05.008 · Cited by 223
Ngia, L. S. H., & Sjoberg, J. (2000) · IEEE Transactions on Signal Processing · doi:10.1109/78.847778 · Cited by 189
Calibration methods for inertial and magnetic sensors
Bonnet, S., Bassompierre, C., Godin, C., Lesecq, S., & Barraud, A. (2009) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2009.10.008 · Cited by 176
Research works printed but not linked: 9
- 0, STEVAL-MKI062V2STMicroelectronics
- 0, MicroStrain Inertial Systems3DM-GX2
- 0, ADIS16405 High Precision Tri-Axis Gyroscope Accelerometer Magnetometer Inertial Sensors Sensors Analog Devices
- 0, Attitude and Heading Reference System Innalabs AHRS M3 Datasheet
- 0, Crossbow Accelerometers High Sensitivity LF Series
- ranganathan, 2004, The LevenbergMarquardt Algorithm
- gavin, 2011, The Levenberg–Marquardt method for nonlinear least squares curve-fitting problems, Dept Civil and Environmental Engineering Duke Univ
- sotk, 2006, Navigation System Integration
- 0, Find Minimum of Unconstrained Multivariable FunctionMATLAB
Cited by
Stamatakis, E., Ahmadi, M. N., Gill, J. M. R., Thøgersen-Ntoumani, C., Gibala, M. J., Doherty, A., & Hamer, M. (2022) · Nature Medicine · doi:10.1038/s41591-022-02100-x · Cited by 336
del Pozo Cruz, B., Ahmadi, M. N., Lee, I.-M., & Stamatakis, E. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.4000 · Cited by 265
MEMS Inertial Sensor Calibration Technology: Current Status and Future Trends
Ru, X., Gu, N., Shang, H., & Zhang, H. (2022) · Micromachines · doi:10.3390/mi13060879 · Cited by 184
Vigorous physical activity, incident heart disease, and cancer: how little is enough?
Ahmadi, M. N., Clare, P. J., Katzmarzyk, P. T., del Pozo Cruz, B., Lee, I. M., & Stamatakis, E. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac572 · Cited by 175
“Participants returned the devices by mail and the data were calibrated and non-wear periods were identified according to standard procedures.(14,15) Monitoring days were considered valid if wear time was greater than 16 h.”
MethodAhmadi, M. N., Hamer, M., Gill, J. M. R., Murphy, M., Sanders, J. P., Doherty, A., & Stamatakis, E. (2023) · The Lancet Public Health · doi:10.1016/s2468-2667(23)00183-4 · Cited by 172
Metadata
- Authors
- Sipos, M., Paces, P., Rohac, J., & Novacek, P.
- Venue
- IEEE Sensors Journal
- Published
- 2012-05
- Volume
- 12
- Issue
- 5
- Pages
- 1157-1165
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W1996331830
- Cited by
- 145
- References
- 24
- Citations by year
- 2026: 6 · 2025: 14 · 2024: 24 · 2023: 13 · 2022: 11 · 2021: 13 · 2020: 8 · 2019: 7 · 2018: 10 · 2017: 7 · 2016: 8 · 2015: 7 · 2014: 8 · 2013: 6 · 2012: 3
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Sensors Journal (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
- Keywords
- triaxial accelerometer, sensor calibration, sensor error models, scale factor error, offset error, Levenberg-Marquardt algorithm, low-cost calibration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analyses of Triaxial Accelerometer Calibration Algorithms. https://app.cochat.ai/papers/10.1109/jsen.2011.2167319
- The paper
- Sipos, M., Paces, P., Rohac, J., & Novacek, P. (2012). Analyses of Triaxial Accelerometer Calibration Algorithms. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2011.2167319
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.