Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 386

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

A new multi-position calibration method for MEMS inertial navigation systems

Syed, Z F, Aggarwal, P, Goodall, C, Niu, X, El-Sheimy, N · 2007 · Measurement Science and Technology

Abstract

The Global Positioning System (GPS) is a worldwide navigation system that requires a clear line of sight to the orbiting satellites. For land vehicle navigation, a clear line of sight cannot be maintained all the time as the vehicle can travel through tunnels, under bridges, forest canopies or within urban canyons. In such situations, the augmentation of GPS with other systems is necessary for continuous navigation. Inertial sensors can determine the motion of a body with respect to an inertial frame of reference. Traditionally, inertial systems are bulky, expensive and controlled by government regulations. Micro-electro mechanical systems (MEMS) inertial sensors are compact, small, inexpensive and most importantly, not controlled by governmental agencies due to their large error characteristics. Consequently, these sensors are the perfect candidate for integrated civilian navigation applications with GPS. However, these sensors need to be calibrated to remove the major part of the deterministic sensor errors before they can be used to accurately and reliably bridge GPS signal gaps. A new multi-position calibration method was designed for MEMS of high to medium quality. The method does not require special aligned mounting and has been adapted to compensate for the primary sensor errors, including the important scale factor and non-orthogonality errors of the gyroscopes. A turntable was used to provide a strong rotation rate signal as reference for the estimation of these errors. Two different quality MEMS IMUs were tested in the study. The calibration results were first compared directly to those from traditional calibration methods, e.g. six-position and rate test. Then the calibrated parameters were applied in three datasets of GPS/INS field tests to evaluate their accuracy indirectly by comparing the position drifts during short-term GPS signal outages.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-0233/18/7/016

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 386

Metadata

Authors
Syed, Z. F., Aggarwal, P., Goodall, C., Niu, X., & El-Sheimy, N.
Venue
Measurement Science and Technology
Published
2007-05-15
Volume
18
Issue
7
Pages
1897-1907
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2035179658
Cited by
386
References
4
FWCI
17.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new multi-position calibration method for MEMS inertial navigation systems. https://app.cochat.ai/papers/10.1088/0957-0233/18/7/016
The paper
Syed, Z. F., Aggarwal, P., Goodall, C., Niu, X., & El-Sheimy, N. (2007). A new multi-position calibration method for MEMS inertial navigation systems. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/18/7/016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.