Analyses of Triaxial Accelerometer Calibration Algorithms
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper proposes a calibration procedure in order to minimize the process time and cost. It relies on the suggestion of optimal positions, in which the calibration procedure takes place, and on position number optimization. Furthermore, this paper describes and compares three useful calibration algorithms applicable on triaxial accelerometer to determine its mathematical error model without a need to use an expensive and precise calibration means, which is commonly required. The sensor error model (SEM) of triaxial accelerometer consists of three scale-factor errors, three nonorthogonality angles, and three offsets. For purposes of calibration, two algorithms were tested—the Levenberg–Marquardt and the Thin-Shell algorithm. Both were then related to algorithm based on Matlab fminunc function to analyze their efficiency and results. The proposed calibration procedure and applied algorithms were experimentally verified on accelerometers available on market. We performed various analyses of proposed procedure and proved its capability to estimate the parameters of SEM without a need of precise calibration means, with minimum number of iteration, both saving time, workload, and costs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Monitors were calibrated49 and corrected for orientation50 using previously published methods”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [49]
In the citing paper
“Devices were calibrated and non-wear periods were detected using standard procedures.15,16”
Citations
Cites
Strapdown Inertial Navigation Technology
Titterton, D., & Weston, J. (2004) · Institution of Engineering and Technology eBooks · doi:10.1049/pbra017e · Cited by 3,348
Methods for Non-Linear Least Squares Problems
Madsen, K., Nielsen, H. B., & Tingleff, O. (1999) · Cited by 969
Methods for Non-Linear Least Squares Problems (2nd ed.)
Madsen, K., Nielsen, H. B., & Tingleff, O. (2004) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 640
Improved Computation for Levenberg–Marquardt Training
Wilamowski, B. M., & Yu, H. (2010) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2010.2045657 · Cited by 622
Inertial sensor technology trends
Barbour, N., & Schmidt, G. (2001) · IEEE Sensors Journal · doi:10.1109/7361.983473 · Cited by 588
A new multi-position calibration method for MEMS inertial navigation systems
Syed, Z. F., Aggarwal, P., Goodall, C., Niu, X., & El-Sheimy, N. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/7/016 · Cited by 386
Calibration of a MEMS inertial measurement unit
Skog, I., & Händel, P. (2006) · Cited by 223
Calibration and data fusion solution for the miniature attitude and heading reference system
Jurman, D., Jankovec, M., Kamnik, R., & Topič, M. (2007) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.05.008 · Cited by 223
Ngia, L. S. H., & Sjoberg, J. (2000) · IEEE Transactions on Signal Processing · doi:10.1109/78.847778 · Cited by 189
Calibration methods for inertial and magnetic sensors
Bonnet, S., Bassompierre, C., Godin, C., Lesecq, S., & Barraud, A. (2009) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2009.10.008 · Cited by 176
Research works printed but not linked: 9
- 0, STEVAL-MKI062V2STMicroelectronics
- 0, MicroStrain Inertial Systems3DM-GX2
- 0, ADIS16405 High Precision Tri-Axis Gyroscope Accelerometer Magnetometer Inertial Sensors Sensors Analog Devices
- 0, Attitude and Heading Reference System Innalabs AHRS M3 Datasheet
- 0, Crossbow Accelerometers High Sensitivity LF Series
- ranganathan, 2004, The LevenbergMarquardt Algorithm
- gavin, 2011, The Levenberg–Marquardt method for nonlinear least squares curve-fitting problems, Dept Civil and Environmental Engineering Duke Univ
- sotk, 2006, Navigation System Integration
- 0, Find Minimum of Unconstrained Multivariable FunctionMATLAB
Cited by
Items 101–160 of 160
Ahmadi, M. N., Koemel, N. A., Biswas, R. K., Holtermann, A., Koster, A., Atkin, A. J., Pulsford, R. M., Cruz, B. D. P., Rangul, V., Mitchell, J. J., et al. (2026) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-026-01930-z · Cited by 3
Chaput, J., Biswas, R. K., Ahmadi, M., Cistulli, P. A., Bian, W., & Stamatakis, E. (2026) · SLEEP · doi:10.1093/sleep/zsag193 · Cited by 3
Vibration-based condition monitoring of wind turbine blades
Esu, O. O. (2016) · Loughborough University Institutional Repository (Loughborough University) · Cited by 3
Inertial Tracking System for Monitoring Dual Mobility Hip Implants In Vitro
Shuttleworth, M. P., Vickers, O., Smeeton, M., Tim Board, Isaac, G. H., Culmer, P., Williams, S., & Kay, R. W. (2023) · Sensors · doi:10.3390/s23020904 · Cited by 3
Sarkar, A. K. (2014) · Griffith Research Online · doi:10.25904/1912/476 · Cited by 3
Teng, F., Zhang, W., & Zhang, Z. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3541659 · Cited by 3
Su, X., Liu, J., Xu, J., & Chen, P. (2025) · Measurement Science Review · doi:10.2478/msr-2025-0015 · Cited by 3
Generation of Wide-Pulsewidth Synchronous Shocks and Calibration for Triaxial Accelerometers
Wang, Q., Xu, F., & Guo, W. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3368484 · Cited by 3
Gradient methodology for 3-axis accelerometer static calibration
Draganová, K., Laššák, M., Lipovský, P., Kan, V. L., & Kliment, T. (2015) · International Conference on Military Technologies · doi:10.1109/miltechs.2015.7153667 · Cited by 3
In-field gyroscope autocalibration with iterative attitude estimation
Wang, L., Duffield, R., Fox, D., Hammond, A., Zhang, J. A., Zheng, W. X., & Su, S. W. (2024) · Mechatronics · doi:10.1016/j.mechatronics.2024.103232 · Cited by 3
Planetary navigation activity recognition using wearable accelerometer data
Song, W. W. (2013) · K-State Research Exchange (Kansas State University) · Cited by 2
In-flight alignment of distributed all-accelerometer network
Al-Rawashdeh, Y. M., Mysorewala, M. F., & Elshafei, M. (2017) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2017.7894060 · Cited by 2
Numerical Methods of Suboptimal Programs Synthesis for Accelerometer Unit
Egorov, Y. G., Kiryachenko, G. Y., & Popov, E. A. (2021) · Gyroscopy and Navigation · doi:10.1134/s2075108721020036 · Cited by 2
PCA-aided calibration of systems comprising multiple unbiased sensors
Rupniewski, M. W. (2023) · IEEE Statistical Signal Processing Workshop (SSP) · doi:10.1109/ssp53291.2023.10207946 · Cited by 2
Improvement of Inertial Navigation System Accuracy Using Alternative Sensors
Šipoš, M. (2015) · Czech Technical University Digital Library (Czech Technical University in Prague) · Cited by 2
Wei, L., Ahmadi, M. N., Biswas, R. K., Trost, S. G., & Stamatakis, E. (2024) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14719 · Cited by 1
Ahmadi, M. N., Koemel, N. A., Biswas, R. K., Chen, S., Pulsford, R. M., Hamer, M., & Stamatakis, E. (2024) · medRxiv · doi:10.1101/2024.08.06.24311529 · Cited by 2
Šarčević, P. (2019) · SZTE Repository of Dissertations (University of Szeged) · doi:10.14232/phd.9949 · Cited by 1
Long-term Stability of Alignment of Biaxial Microelectromechanical System Accelerometers
Luczak, S., Zaczyk, M., & Grzywacz, H. (2024) · Acta Physica Polonica A · doi:10.12693/aphyspola.146.325 · Cited by 1
Avallone, G. (2023) · AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna) · doi:10.48676/unibo/amsdottorato/10722 · Cited by 1
Triaxial Sensor Calibration: A Prototype for Accelerometer and Gyroscope Calibration
Bernal-Polo, P., & Barberá, H. M. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-70836-2_7 · Cited by 1
Dai, W., Han, H., Liu, G., Wang, J., & Xiao, X. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3614580 · Cited by 1
Maton, D., Economou, J. T., Wall, D. G., Khan, I., Cooper, R., Trythall, S., & Kitching, S. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117300 · Cited by 1
An analysis of the calibration method of accelerometer bias and scale factor
Jia, J., Zheng, J., & Wang, X. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/787/1/012001 · Cited by 1
A method for improving the performance of centering rod surveying based on two-position correction
Dai, M., Pan, X., Yang, Y., Zhi-cheng, L., & Zhu, Y. M. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac5a2e · Cited by 1
Measurements of Acceleration as a Basis for Designing New Devices
Zams, M., Pieńczuk, P., & Łuczak, S. (2024) · Acta Physica Polonica A · doi:10.12693/aphyspola.146.419 · Cited by 1
Investigation of Three-Axis Accelerometer Calibration Techniques
Archer, A. (2017) · Iowa Research Online (The University of Iowa) · Cited by 1
Mitchell, J. J., Biswas, R. K., Koemel, N. A., Ahmadi, M. N., Blodgett, J. M., Canfell, K., Lee, I.-M. M., Friedenreich, C. M., Teixeira-Pinto, A. M., Cistulli, P. A., et al. (2026) · BMC Medicine · doi:10.1186/s12916-026-05069-3
Sabag, A., Biswas, R. K., Koemel, N. A., François, M. E., Keating, S. E., Gibala, M. J., Little, J. P., Johnson, N. A., Stamatakis, E., & Ahmadi, M. N. (2026) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgag316
Rezende, L. F. M., Ahmadi, M., Ferrari, G., del Pozo Cruz, B., Lee, I.-M. M., Ekelund, U., & Stamatakis, E. (2024) · Figshare · doi:10.6084/m9.figshare.26170679
Rezende, L. F. M., Ahmadi, M., Ferrari, G., del Pozo Cruz, B., Lee, I.-M. M., Ekelund, U., & Stamatakis, E. (2024) · Figshare · doi:10.6084/m9.figshare.26170522
Boidin, M., Buckley, B. J. R., Lip, G. Y. H., & Thijssen, D. H. J. (2025) · American Journal of Preventive Cardiology · doi:10.1016/j.ajpc.2025.101362
Smart Cricket Ball: Solutions to Design and Deployment Challenges
Balbudhe, P., Sharma, R., & Solanki, S. (2023) · Lecture notes in networks and systems · doi:10.1007/978-981-99-4071-4_32
Zhou, W., Li, Z., Bai, L., Fu, X., Qu, B., & Miao, M. (2023) · Springer eBooks · doi:10.1007/978-981-10-3593-7_1
Harding, S. A., Richardson, A., Glynn, A., Middleton, L., & Hodgson, L. E. (2026) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412555.2026.2713066
Implementation of Innovations in Technologies Experience of the Czech Republic
(2023) · Tuculart Edition eBooks · doi:10.47451/book-2026-04
Zheng, G., Yuan, B., Lv, F., Shen, Q., Tang, Z., & Zheng, S. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ad4dc4
Contributions to geometric observer design for visual-inertial navigation
Bouazza, T. (2024) · theses.fr (ABES) · doi:10.70675/3f6d92c1zb960z4374z823bz61d974615240
Beyond the Lab: Challenges to Detect Parkinson’s Disease Symptoms in Remote Smartwatch Data
Schut, I. (. (2024) · Research Repository (Delft University of Technology)
Modified Biaxial Accelerometer Framework in G-sensing Mode
Roháč, J., Šipoš, M., & Ďaďo, S. (2020) · Transactions on Electrical Engineering · doi:10.14311/tee.2016.1.021
Computation-Efficient Precise Determination of Tilt Using Acceleration Measurements
Zams, M., & Łuczak, S. (2024) · Acta Physica Polonica A · doi:10.12693/aphyspola.146.630
A Traceable Vectorial Calibration for MEMS Accelerometers Using Industrial Robotic Manipulators
Costa, G. D. O., & da Motta, J. M. S. T. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3723731
Mitchell, J. J., Biswas, R. K., Blodgett, J. M., Koemel, N. A., Ahmadi, M. N., Fisher, A., Friedenreich, C. M., Canfell, K., Lee, I.-M. M., Cistulli, P. A., et al. (2026) · medRxiv · doi:10.64898/2026.06.09.26355299
Wahyudi, W., Ngatelan, N., & Widada, W. (2016) · Transmisi: Jurnal Ilmiah Teknik Elektro · doi:10.12777/transmisi.18.2.42-48
An Inertial Pen to Recognize Handwriting & Gesture using DTW Algorithm
Srikant, S. S. (2018) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2018.3718
Parameter estimation and application for static nonlinear and dynamic linear systems
Ye, L. (2018) · OPUS - Open Publications of UTS Scholars (University of Technology Sydney)
Accelerometer Calibration Based on Spectral Analysis
Draganová, K., Lipovský, P., & Šmelko, M. (2018) · New Trends in Signal Processing (NTSP) · doi:10.23919/ntsp.2018.8524056
Stabilizovaný tříosý cívkový systém pro kalibrace magnetometru
Dressler, M. (2019) · Cvut DSpace (Czech Technical University)
Bréda, R., Karaffa, Š., Andoga, R., & Hlinková, M. (2023) · International Journal of Aerospace Engineering · doi:10.1155/2023/9252640
Research on Contact-Type Gravity Field Testing Method for JN-06 Accelerometer Based on Turntable
Lu, L., Xu, X., & He, H. (2024) · IEEE International Conference on Advanced Information, Mechanical Engineering, Robotics and Automation (AIMERA) · doi:10.1109/aimera59657.2024.10735454
Implementation of medium and low precision IMUs for the design of integration architectures
Bréda, R., & Vološin, M. (2024) · New Trends in Aviation Development (NTAD) · doi:10.1109/ntad63796.2024.10850384
Control Method and Implementation of Multi-component Calibration High Impact Test System
Tong, K., Cheng, Y., Li, Y., Zhang, Z., Zeng, T., He, G. L., & Cai, D. (2025) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma65362.2025.11120539
Decoupling control for tri-axial standard vibrator based on optimized neural network inverse model
Zhang, X., Cao, C., Wang, S., Liu, X., & Quan, L. (2025) · Journal of Vibration and Control · doi:10.1177/10775463251391863
Netradiční metody měření polohových úhlů v letectví
Pačes, P. (2013) · Czech Technical University Digital Library (Czech Technical University in Prague)
Navigation System for Unmanned Vehicles and Ultra-light Aircrafts
Brož, P., & Pavel, B. (2015) · Cvut DSpace (Czech Technical University)
Paclík, M., & Martin, P. (2019) · Czech Technical University Digital Library (Czech Technical University in Prague)
Calibration and sensor fusion techniques for portable, homogeneous accelerometer systems
Mehciz, B. (2017) · John Spoor Broome Library Institutional Repository (California State University)
Calibration of low-grade inertial measurement unit sensors using real-coded genetic algorithms
Pham, M., & Yoon, K.-K. (2025) · Journal of Advanced Marine Engineering and Technology · doi:10.5916/jamet.2025.49.6.560
A High-Precision and Easy to Encode Precise Solution Scheme for Calculating Attitude Angles
Yang, H., Liang, Y., Yu, H., & Zeng, X. (2025) · IEEE International Conference on Applied Mathematics, Modeling and Computer Simulation (AMMCS) · doi:10.1109/ammcs65761.2025.11459884
Attitude-Aided Linear Calibration of Triaxial AccelerometersPreprint
Yu, Y., Huang, T., & Yang, Y. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2606.06308
Metadata
- Authors
- Sipos, M., Paces, P., Rohac, J., & Novacek, P.
- Venue
- IEEE Sensors Journal
- Published
- 2012-05
- Volume
- 12
- Issue
- 5
- Pages
- 1157-1165
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W1996331830
- Cited by
- 145
- References
- 24
- Citations by year
- 2026: 6 · 2025: 14 · 2024: 24 · 2023: 13 · 2022: 11 · 2021: 13 · 2020: 8 · 2019: 7 · 2018: 10 · 2017: 7 · 2016: 8 · 2015: 7 · 2014: 8 · 2013: 6 · 2012: 3
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Sensors Journal (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
- Keywords
- triaxial accelerometer, sensor calibration, sensor error models, scale factor error, offset error, Levenberg-Marquardt algorithm, low-cost calibration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.