The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Displacement Sensor Based on Diamond-Shaped Tapered Split Ring Resonator
Abstract
Split-ring resonators (SRRs) are ideal structures for the realization of compact high-sensitivity and high-resolution sensors due to their high-quality factor resonance, compact size, and high sensitivity to changes in the constituent materials and physical dimensions. This paper presents a displacement sensor based on a diamond-shaped tapered SRR coupled to a coplanar waveguide. Two significant improvements over previous designs are reported. Firstly, the proposed sensor has higher dynamic range and linearity for displacement sensing. Secondly, compared with previous designs, where the displacement changes both the resonant frequency and depth of the transmission notch, the proposed sensor has a fixed resonant frequency. This is an important improvement since the sensor can be operated at a single fixed frequency and bypass the need for a frequency-sweeping microwave source and measurement system such as an expensive network analyzer. It is shown that, while preserving the compact size, the proposed sensor also benefits from a lower operating frequency. The design principle and simulation results are validated through measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Controlling Electromagnetic Fields
Pendry, J. B., Schurig, D., & Smith, D. R. (2006) · Science · doi:10.1126/science.1125907 · Cited by 8,589
A Metamaterial for Directive Emission
Enoch, S., Tayeb, G., Sabouroux, P., Guérin, N., & Vincent, P. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.213902 · Cited by 1,240
Role of bianisotropy in negative permeability and left-handed metamaterials
Marqués, R., Medina, F., & Rafii-El-Idrissi, R. (2002) · Physical Review B · doi:10.1103/physrevb.65.144440 · Cited by 781
The Road Ahead for Metamaterials
Zheludev, N. I. (2010) · Science · doi:10.1126/science.1186756 · Cited by 727
Split ring resonator-based left-handed coplanar waveguide
Martı́n, F., Bonache, J., Falcone, F., Sorolla, M., & Marqués, R. (2003) · Applied Physics Letters · doi:10.1063/1.1631392 · Cited by 388
Split ring resonator sensors for infrared detection of single molecular monolayers
Cubukcu, E., Zhang, S., Park, Y.-S., Bartal, G., & Zhang, X. (2009) · Applied Physics Letters · doi:10.1063/1.3194154 · Cited by 275
Electromagnetic cloaking with metamaterials
Alitalo, P., & Tretyakov, S. (2009) · Materials Today · doi:10.1016/s1369-7021(09)70072-0 · Cited by 268
Dielectric sensing inϵ-near-zero narrow waveguide channels
Alù, A., & Engheta, N. (2008) · Physical Review B · doi:10.1103/physrevb.78.045102 · Cited by 170
Metamaterial-Inspired Multichannel Thin-Film Sensor
Withayachumnankul, W., Jaruwongrungsee, K., Fumeaux, C., & Abbott, D. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2173762 · Cited by 110
Self-citation
Metadata
- Authors
- Horestani, A. K., Fumeaux, C., Al-Sarawi, S. F., & Abbott, D.
- Venue
- IEEE Sensors Journal
- Published
- 2013-04
- Volume
- 13
- Issue
- 4
- Pages
- 1153-1160
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2020584972
- Cited by
- 273
- References
- 15
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Displacement Sensor Based on Diamond-Shaped Tapered Split Ring Resonator. https://app.cochat.ai/papers/10.1109/jsen.2012.2231065
- The paper
- Horestani, A. K., Fumeaux, C., Al-Sarawi, S. F., & Abbott, D. (2013). Displacement Sensor Based on Diamond-Shaped Tapered Split Ring Resonator. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2012.2231065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.