Implementation of Tactile Sensing for Palpation in Robot-Assisted Minimally Invasive Surgery: A Review
Open accessAbstract
Robot-assisted minimally invasive surgery (RMIS) made it possible to perform a number of medical manipulations with reduced patient trauma and better accuracy. Various devices, including tactile sensors, have been developed in recent years to enhance the quality of this procedure. The objective of this paper is to review the latest advancements and challenges in the development of tactile sensing devices designed for surgical applications. In particular, the focus is on palpation and probing devices that can be potentially used in RMIS. In addition, we explore the aspects that should be taken into account when designing tactile sensors for RMIS, incorporating biological inspiration of tactile sensing, features of manual palpation, requirements of RMIS. We provide an overview of recommendations for the development of tactile sensing devices, especially in the context of RMIS.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
WARWICK, R., Williams, P. L., Dyson, M., & Bannister, L. (1985) · British Journal of Radiology · doi:10.1259/0007-1285-58-694-1029 · Cited by 4,532
Tactile Sensing—From Humans to Humanoids
Dahiya, R., Giorgio Metta, B., Valle, M., & Sandini, G. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2033627 · Cited by 1,890
Gray’s Anatomy: the anatomical basis of clinical practice
Horan, F. (2009) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.91b7.22719 · Cited by 1,766
The roles and functions of cutaneous mechanoreceptors.
Johnson, K. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00234-8 · Cited by 1,063
(1984) · PubMed · Cited by 908
Microelectromechanical systems (MEMS): fabrication, design and applications
Judy, J. W. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/6/301 · Cited by 831
Tactile sensing for dexterous in-hand manipulation in robotics—A review
Yousef, H., Boukallel, M., & Althoefer, K. A. (2011) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.02.038 · Cited by 786
Kim, D., Lu, N., Ghaffari, R., Kim, Y., Lee, S. P., Xu, L., Wu, J. C., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 766
Review Article Tactile sensing for mechatronics—a state of the art survey
Lee, M. H., & Nicholls, H. R. (1999) · Mechatronics · doi:10.1016/s0957-4158(98)00045-2 · Cited by 711
Tactile sensory coding in the glabrous skin of the human hand
Johansson, R. S., & Vallbo, Å. B. (1983) · Trends in Neurosciences · doi:10.1016/0166-2236(83)90011-5 · Cited by 680
Rose, D., Boyar, A. P., & Wynder, E. L. (1986) · Cancer · doi:10.1002/1097-0142(19861201)58:11 · Cited by 593
State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery
Puangmali, P., Althoefer, K. A., Seneviratne, L. D., Murphy, D., & Prokar Dasgupta, A. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917481 · Cited by 588
Robotic technology in surgery: Past, present, and future
Camarillo, D. B., Krummel, T. M., & Salisbury, J. K. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.025 · Cited by 537
Human tactile perception as a standard for artificial tactile sensing - a review
Dargahi, J., & Najarian, S. (2004) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.3 · Cited by 407
In vivo model of the mechanical properties of the human skin under suction
Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J., Gall, Y., & Berson, M. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006004214.x · Cited by 350
Hendriks, F. M., Brokken, D., Oomens, C. W. J., Bader, D. L., & Baaijens, F. F. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.07.001 · Cited by 337
Phillips, J. R., & Johnson, K. (1981) · Journal of Neurophysiology · doi:10.1152/jn.1981.46.6.1192 · Cited by 333
Force Feedback Plays a Significant Role in Minimally Invasive Surgery
Tholey, G., Desai, J. P., & Castellanos, A. E. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000149301.60553.1e · Cited by 331
Tactile detection of slip: surface microgeometry and peripheral neural codes
Srinivasan, M. A., Whitehouse, J. M., & LaMotte, R. H. (1990) · Journal of Neurophysiology · doi:10.1152/jn.1990.63.6.1323 · Cited by 290
In situforce mapping of mammary gland transformation
Lopez, J. I., Kang, I., You, W., McDonald, D. M., & Weaver, V. M. (2011) · Integrative Biology · doi:10.1039/c1ib00043h · Cited by 284
Miniature 3-Axis Distal Force Sensor for Minimally Invasive Surgical Palpation
Puangmali, P., Liu, H., Seneviratne, L. D., Prokar Dasgupta, A., & Althoefer, K. A. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2116033 · Cited by 248
Results of the NeuroBlate System first-in-humans Phase I clinical trial for recurrent glioblastoma
Sloan, A. E., Ahluwalia, M. S., Valerio-Pascua, J., Manjila, S. V., Torchia, M. G., Jones, S. E., Sunshine, J. L., Phillips, M., Griswold, M. A., Clampitt, M. E., et al. (2013) · Journal of neurosurgery · doi:10.3171/2013.1.jns1291 · Cited by 247
Validation and implementation of surgical simulators: a critical review of present, past, and future
Schout, B. M. A., Hendrikx, A. J. M., Scheele, F., Bemelmans, B. L. H., & Scherpbier, A. J. J. A. (2009) · Surgical Endoscopy · doi:10.1007/s00464-009-0634-9 · Cited by 236
Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery
King, C., Culjat, M. O., Franco, M. L., Lewis, C. E., Dutson, E., Grundfest, W. S., & Bisley, J. W. (2009) · IEEE Transactions on Haptics · doi:10.1109/toh.2009.4 · Cited by 229
Effects of visual force feedback on robot-assisted surgical task performance
Reiley, C. E., Akinbiyi, T., Burschka, D., Chang, D. C., Okamura, A. M., & Yuh, D. D. (2008) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.08.043 · Cited by 228
Tactile sensing technology for minimal access surgery––a review
Eltaib, M. E. H., & Hewit, J. R. (2003) · Mechatronics · doi:10.1016/s0957-4158(03)00048-5 · Cited by 222
Pressure-Controlled Palpation: A New Technique Which Increases the Reliability of Manual Palpation
Bendtsen, L., Jensen, R., Jensen, N., & Olesen, J. (1995) · Cephalalgia · doi:10.1046/j.1468-2982.1995.015003205.x · Cited by 167
An MRI-Compatible Surgical Robot for Precise Radiological Interventions
Hempel, E., Fischer, H., Gumb, L., Höhn, T., Krause, H., Voges, U., Breitwieser, H., Gutmann, B., Durke, J., Bock, M., et al. (2003) · Computer Aided Surgery · doi:10.3109/10929080309146052 · Cited by 135
Review on aspects of artificial tactile feedback in laparoscopic surgery
Schostek, S., Schurr, M. O., & Buess, G. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.06.003 · Cited by 128
The pipette aspiration applied to the local stiffness measurement of soft tissues
Aoki, T., OHASHI, T., MATSUMOTΟ, T., & Sato, M.-A. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684197 · Cited by 127
Vega‐Bermudez, F., & Johnson, K. O. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.6.2701 · Cited by 126
Johansson, R. S., Landstro¨m, U., & Lundström, R. (1982) · Brain Research · doi:10.1016/0006-8993(82)90900-3 · Cited by 113
Rolling Mechanical Imaging for Tissue Abnormality Localization During Minimally Invasive Surgery
Liu, H., Noonan, D. P., Challacombe, B. J., Prokar Dasgupta, A., Seneviratne, L. D., & Althoefer, K. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2032164 · Cited by 106
Ahmadi, R., Packirisamy, M., Dargahi, J., & Cecere, R. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2113394 · Cited by 101
Seifert, V., Zimmermann, M., Trantakis, C., Vitzthum, H. E., Kühnel, K., Raabe, A., Bootz, F., Schneider, J. ‐., Schmidt, F. M., & Dietrich, J. (1999) · Acta Neurochirurgica · doi:10.1007/s007010050325 · Cited by 98
A Robust Uniaxial Force Sensor for Minimally Invasive Surgery
Yip, M. C., Yuen, S. G., & Howe, R. D. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2039570 · Cited by 97
Distribution of Human Pacinian Corpuscles in the Hand: A cadaver study
STARK, B., CARLSTEDT, T., HALLIN, R. G., & RISLING, M. (1998) · Journal of Hand Surgery · doi:10.1016/s0266-7681(98)80060-0 · Cited by 97
Ahn, B., Kim, J., Ian, L. R., Rha, K. H., & Kim, H. J. (2010) · Urology · doi:10.1016/j.urology.2010.02.025 · Cited by 95
Rolling Indentation Probe for Tissue Abnormality Identification During Minimally Invasive Surgery
Liu, H., Li, J., Song, X., Seneviratne, L. D., & Althoefer, K. A. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2127210 · Cited by 94
Comparison of MRI-Compatible Mechatronic Systems With Hydrodynamic and Pneumatic Actuation
Yu, N., Hollnagel, C., Blickenstorfer, A., Kollias, S., & Riener, R. (2008) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.924041 · Cited by 94
Cardiovascular Interventional Magnetic Resonance Imaging
Lederman, R. J. (2005) · Circulation · doi:10.1161/circulationaha.104.531368 · Cited by 93
MRI-Compatible Intensity-Modulated Force Sensor for Cardiac Catheterization Procedures
Polygerinos, P., Ataollahi, A., Schaeffter, T., Razavi, R., Seneviratne, L. D., & Althoefer, K. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2095853 · Cited by 93
Artificial tactile sensing in minimally invasive surgery – a new technical approach
Schostek, S., Ho, C., Kalanovic, D., & Schurr, M. O. (2006) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700600836299 · Cited by 91
Fine-needle aspiration biopsy in diagnosis of soft tissue infections
Lee, P. C., Turnidge, J. D., & McDonald, P. J. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.22.1.80-83.1985 · Cited by 78
Human tactile perception as a standard for artificial tactile sensing - a review
Dargahi, J., & Najarian, S. (2004) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1581/mrcas.2004.010109 · Cited by 73
Prevost, A. M., Scheibert, J., & Debrégeas, G. (2009) · Communicative & Integrative Biology · doi:10.4161/cib.2.5.9052 · Cited by 71
Status of robotic assistance—a less traumatic and more accurate minimally invasive surgery?
Kenngott, H., Fischer, L., Nickel, F., Rom, J., Rassweiler, J. J., & Müller-Stich, B. P. (2011) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-011-0859-7 · Cited by 71
MEMS Endoscopic Tactile Sensor: TowardIn-SituandIn-VivoTissue Softness Characterization
Sokhanvar, S., Packirisamy, M., & Dargahi, J. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2025586 · Cited by 65
Clinical Benefits of Minimally Invasive Techniques in Thyroid Surgery
Perigli, G., Cortesini, C., Qirici, E., Boni, D., & Cianchi, F. (2007) · World Journal of Surgery · doi:10.1007/s00268-007-9259-0 · Cited by 63
Palpation instrument for augmented minimally invasive surgery
Ottermo, M. V., Stavdahl, Ø., & Johansen, T. A. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2004.1390033 · Cited by 62
Triaxial MRI-Compatible Fiber-optic Force Sensor
Tan, U.-X., Yang, B. F., Gullapalli, R. P., & Desai, J. P. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2090061 · Cited by 59
Skin spatial calibration using force/torque measurements
Prete, A. D., Denei, S., Natale, L., Mastrogiovanni, F., Nori, F., Cannata, G., & Giorgio Metta, B. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094896 · Cited by 53
Minimally invasive cardiac surgery
Mack, M. J. (2006) · Surgical Endoscopy · doi:10.1007/s00464-006-0110-8 · Cited by 52
The DLR artificial skin step I: Uniting sensitivity and collision tolerance
Strohmayr, M., Wörn, H., & Hirzinger, G. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630697 · Cited by 49
Soft tactile sensor arrays for micromanipulation
Hammond, F. L., Kramer, R. K., Wan, Q., Howe, R. D., & Wood, R. J. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386224 · Cited by 48
A robotic indenter for minimally invasive characterization of soft tissues
Samur, E., Sedef, M., Başdoğan, Ç., Avtan, L., & Düzgün, O. (2005) · International Congress Series · doi:10.1016/j.ics.2005.03.117 · Cited by 47
Active touch for robust perception under position uncertainty
Lepora, N. F., Martínez-Hernández, U., & Prescott, T. J. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630996 · Cited by 47
Karduna, A. R., Halperin, H. R., & Yin, F. C. P. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684136 · Cited by 43
Highly Sensitive Compact Force Sensor Based on Microfiber Bragg Grating
Chung, K. M., Liu, Z., Lü, C., & Tam, H. (2012) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2012.2187049 · Cited by 41
Nichols, K. A., & Okamura, A. M. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631198 · Cited by 41
Salzinger, K. (1969) · Psychology · doi:10.1007/978-3-662-38301-8_6 · Cited by 29
New tactile sensing system for minimally invasive surgical tumour localization
Perri, M. T., Trejos, A. L., Naish, M. D., Patel, R. V., & Malthaner, R. A. (2010) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.308 · Cited by 29
Quantifying Palpation Techniques in Relation to Performance in a Clinical Prostate Exam
Wang, N., Gerling, G. J., Childress, R. M., & Martin, M. L. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2041064 · Cited by 29
Munger, B. L., & Idé, C. (1987) · Neuroscience Research · doi:10.1016/0168-0102(87)90019-8 · Cited by 28
Sterilization and care of surgical instruments and supplies
Sebben, J. E. (1984) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(84)70179-4 · Cited by 27
Hand-held resonance sensor for tissue stiffness measurements—a theoretical and experimental analysis
Jalkanen, V. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/5/055801 · Cited by 23
Wireless tissue palpation: Proof of concept for a single degree of freedom
Beccani, M., Natali, C. D., Rentschler, M. E., & Valdastri, P. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630651 · Cited by 21
Ahmadi, R., Dargahi, J., Packirisamy, M., & Cecere, R. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690287 · Cited by 21
Characterization of an air jet haptic lump display
Bianchi, M., Gwilliam, J. C., Değirmenci, A., & Okamura, A. M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090937 · Cited by 20
Design, fabrication, and testing of a piezoresistive hardness sensor in Minimally Invasive Surgery
Kalantari, M., Ramezanifard, M., Ahmadi, R., Dargahi, J., & Kövecses, J. (2010) · IEEE Haptics Symposium · doi:10.1109/haptic.2010.5444620 · Cited by 20
Graphical display of tactile sensing data with application in minimally invasive surgery
Dargahi, J., Najarian, S., & Ramezanifard, R. (2007) · Canadian Journal of Electrical and Computer Engineering · doi:10.1109/cjece.2007.4413126 · Cited by 19
Schiavone, P., Boudou, T., Promayon, E., Perrier, P., & Yohan Payan, A. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650160 · Cited by 19
A micro-tactile sensor for in situ tissue characterization in minimally invasive surgery
Qasaimeh, M. A., Sokhanvar, S., Dargahi, J., & Kahrizi, M. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9197-0 · Cited by 18
Instrumentation, sterilization, and preparation of robot
Bhandari, A., Hemal, A., & Menon, M. (2005) · Indian Journal of Urology · doi:10.4103/0970-1591.19626 · Cited by 18
A novel MRI compatible air-cushion tactile sensor for Minimally Invasive Surgery
Zbyszewski, D., Polygerinos, P., Seneviratne, L. D., & Althoefer, K. A. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354140 · Cited by 18
Minimally Invasive Cardiac Surgery Defined
Duhaylongsod, F. G. (2000) · Archives of Surgery · doi:10.1001/archsurg.135.3.296 · Cited by 17
Novel indentation depth measuring system for stiffness characterization in soft tissue palpation
Wanninayake, I. B., Seneviratne, L. D., & Althoefer, K. A. (2012) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2012.6225127 · Cited by 16
A piezoresistive based tactile sensor for use in minimally invasive surgery
Atieh, A., Ahmadi, R., Kalantari, M., Dargahi, J., & Packirisamy, M. (2011) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2011.5778607 · Cited by 16
Novel MEMS stiffness sensor for in-vivo tissue characterization measurement
Peng, P., Sezen, S., Rajamani, R., & Erdman, A. G. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332865 · Cited by 15
HOW WELL DOES THE CHEMICLAVE STERILIZE HANDPIECES?
Kolstad, R. A. (1998) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1998.0352 · Cited by 14
Dual-mode compliant optical tactile sensor
Knoop, E., & Rossiter, J. M. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630696 · Cited by 14
Illustrated Manual of Nursing Practice
Volpicello, C. (1991) · AORN Journal · doi:10.1016/s0001-2092(07)66883-5 · Cited by 13
A Novel Tactile Force Probe for Tissue Stiffness Classification
Darvish (2009) · American Journal of Applied Sciences · doi:10.3844/ajassp.2009.512.517 · Cited by 13
A versatile tactile sensor system for covering large and curved surface areas
Zillich, M., & Feiten, W. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6385806 · Cited by 12
Enhancing Clinical Evaluation Skills: Palpation as the Principal Skill
Eberman, L. E., & Finn, M. E. (2010) · Athletic Training Education Journal · doi:10.4085/1947-380x-5.4.170 · Cited by 12
Piezoelectric self-sensing system for tactile intraoperative brain tumor delineation in neurosurgery
Uribe, D. O., Stroop, R., & Wallaschek, J. (2009) · doi:10.1109/iembs.2009.5332409 · Cited by 12
A New Tissue Resonator Indenter Device and Reliability Study
Jia, M. Q., Zu, J. W.-Z., & Hariri, A. (2011) · Sensors · doi:10.3390/s110101212 · Cited by 11
A sensor to measure hardness of human tissue
Moromugi, S., Kumano, S., Ueda, M., Ishimatsu, T., Feng, M. Q., & Tanaka, T. (2006) · doi:10.1109/icsens.2007.355487 · Cited by 11
Probing model tumor interfacial properties using piezoelectric cantilevers
Yegingil, H., Shih, W. Y., & Shih, W. (2010) · Review of Scientific Instruments · doi:10.1063/1.3482055 · Cited by 10
Design of Noncontact Tumor Imager for Video-Assisted Thoracic Surgery
Kawahara, T., Miyata, Y., Akayama, K., Okajima, M., & Kaneko, M. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2078830 · Cited by 10
Wheel/tissue force interaction: A new concept for soft tissue diagnosis during MIS
Zbyszewski, D., Liu, H., Puangmali, P., Althoefer, K. A., Nunes, C. S., Seneviratne, L. D., Challacombe, B. J., Murphy, D., & Prokar Dasgupta, A. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650473 · Cited by 10
Optimum Incision Length for Port Insertion in Laparoscopic Surgery
McKay, D., & Blake, G. (2006) · Annals of The Royal College of Surgeons of England · doi:10.1308/rcsann.2006.88.1.78a · Cited by 9
Towards a minimal architecture for a printable, modular, and robust sensing skin
Buchan, A. D., Bachrach, J. R., & Fearing, R. S. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386210 · Cited by 9
Design of a 3-axial force/torque sensor for arthroscopy force sensing
Cui, Z. Q., Han, Z., Pan, H., Shao, Y.-M., & Zhu, D. (2011) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2011.5985664 · Cited by 9
Willaert, B., Famaey, N., Verbrugghe, P., Reynaerts, D., & BRUSSEL, H. V. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631270 · Cited by 8
Force-velocity modulation strategies for soft tissue examination
Konstantinova, J., Li, M., Aminzadeh, V., Prokar Dasgupta, A., Althoefer, K. A., & Nanayakkara, T. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696622 · Cited by 8
Development of a Novel Deformation-Based Tissue Softness Sensor
Leng, H., & Lin, Y. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2016620 · Cited by 8
Recognition of Tactile Relief by Children and Adults
Shiah, Y., Chang, F., & Tam, W. C. (2011) · Perceptual and Motor Skills · doi:10.2466/10.24.27.pms.113.6.727-738 · Cited by 7
Active tactile sensing of stiffness and surface condition using balloon expansion
Tanaka, Y., Doumoto, K., Akihito, S. A. N. O., & FUJIMOTO, H. (2009) · Conference on Human System Interactions · doi:10.1109/hsi.2009.5090953 · Cited by 5
Air jets imaging tactile sensing device for automation applications
Benhadj, R., & Dawson, B. (1995) · Robotica · doi:10.1017/s0263574700018361 · Cited by 5
Salient Features of Soft Tissue Examination Velocity during Manual Palpation
Konstantinova, J., Althoefer, K. A., Prokar Dasgupta, A., & Nanayakkar, T. (2017) · Queen Mary Research Online (Queen Mary University of London) · Cited by 4
Real-time, non-vision sensory feedback during minimally invasive surgery
Abbas, S. P., Chauhan, S., Phee, S. J., & Lau, G. (2009) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2009.5396013 · Cited by 3
Surface texture and pseudo tactile sensation displayed by a MEMS-based tactile display
Watanabe, J., Ishikawa, H., Arouette, X., & Miki, N. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386218 · Cited by 2
A Novel Tactile Probe with Applications in Biomedical Robotics
Dargahi, J., Najarian, S., & Changizi, M. A. (2006) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2006.296002 · Cited by 1
Inverse problem for stiffness sensing of living soft tissue
Tanaka, N., Higashimori, M., & Kaneko, M. (2010) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.2010.5669571 · Cited by 1
Flagged first, then by citations
2 of the 107 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- cain, 2000, Bio Discovery, 1
- sargeant, 2012, An MRI compatible optical multi-axis force/torque sensors robotic surgery, Proc Hamlyn Simposium
- araghi, 2009, A feedback based dynamic instrument for measuring mechanical properties of soft tissues for minimally-invasive surgery, Proc Smart Mater Struct, 59
Cited by
Sorted by citations
The rise of artificial intelligence in healthcare applications
Bohr, A., & Memarzadeh, K. (2020) · Artificial Intelligence in Healthcare · doi:10.1016/b978-0-12-818438-7.00002-2 · Cited by 1,636
Toward Perceptive Soft Robots: Progress and Challenges
Wang, H., Totaro, M., & Beccai, L. (2018) · Advanced Science · doi:10.1002/advs.201800541 · Cited by 775
Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review
Presti, D. L., Massaroni, C., Leitão, C., Domingues, M. F., Sypabekova, M., Barrera, D., Floris, I., Massari, L., Oddo, C. M., Sales, S., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3019138 · Cited by 392
Novel Tactile Sensor Technology and Smart Tactile Sensing Systems: A Review
Zou, L., Ge, C. C., Wang, Z., Cretu, E., & Li, X. (2017) · Sensors · doi:10.3390/s17112653 · Cited by 277
Attanasio, A., Scaglioni, B., Momi, E. D., Fiorini, P., & Valdastri, P. (2020) · Annual Review of Control Robotics and Autonomous Systems · doi:10.1146/annurev-control-062420-090543 · Cited by 269
Metadata
- Authors
- Konstantinova, J., Jiang, A., Althoefer, K., Dasgupta, P., & Nanayakkara, T.
- Affiliations
- King's College London (GB)
- Venue
- IEEE Sensors Journal
- Published
- 2014-08
- Volume
- 14
- Issue
- 8
- Pages
- 2490-2501
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2019690914
- Cited by
- 166
- References
- 107
- Citations by year
- 2026: 6 · 2025: 21 · 2024: 14 · 2023: 15 · 2022: 15 · 2021: 11 · 2020: 16 · 2019: 18 · 2018: 20 · 2017: 13 · 2016: 12 · 2015: 4 · 2014: 1
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- green
- kclpure.kcl.ac.uk
- Locations
- IEEE Sensors Journal (publishedVersion)
- Research Portal (King's College London) (submittedVersion, other-oa)
- Queen Mary Research Online (Queen Mary University of London) (submittedVersion)
- Funders
- Seventh Framework Program of the European Commission through the framework of European Union Project STIFF-FLOP (287728)
- National Institute for Health Research Biomedical Research Centre through the Guy¿s and St Thomas¿ NHS Foundation Trust and King¿s College London
- Guy¿s and St. Thomas¿ Charity
- Vattikuti Foundation
- National Institute for Health Research Biomedical Research Centre
- Medical Research Council Centre for Transplantation
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Keywords
- tactile sensing, robot-assisted minimally invasive surgery, tactile sensors, manual palpation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review