Textile Fiber Optic Microbend Sensor Used for Heartbeat and Respiration Monitoring
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper reports on a textile fiber optic microbend sensor for heartbeat and respiration monitoring. A section of multimode optical fiber sandwiched between parallel strips acting as a microbender is being integrated onto an elastic substrate. Its design is based on fiber microbending effects. The textile sensor can be used to measure heartbeat and respiration rate simultaneously during standing and sitting position. The detected heart rates from our sensor are in good agreement with that from the commercial SpO2, whereas the respiration rate is verified by counting the breathing manually. We characterize the frequency response of the sensor with a simulation setup and find that the sensitivity of the sensor is large enough at 105 r/min although it decreases with the increase of the motor speed. The textile fiber optic sensor is very comfortable to wear due to the elastic nature of the substrate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ECG patch monitors for assessment of cardiac rhythm abnormalities
Lobodzinski, S. S. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.08.006 · Cited by 119 · cited 1×
“Continuous monitoring of vital signs requires attachment of sensors to the body such as pulse rate can be determined by placement of electrodes on the skin and monitoring of the electrocardiogram [2] and this may cause skin irritation and contribute to patient discomfort.”
Cited by
Internet of Things for Smart Healthcare: Technologies, Challenges, and Opportunities
Baker, S. B., Xiang, W., & Atkinson, I. (2017) · IEEE Access · doi:10.1109/access.2017.2775180 · Cited by 1,130
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Textile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Medical Smart Textiles Based on Fiber Optic Technology: An Overview
Massaroni, C., Saccomandi, P., & Schena, E. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6020204 · Cited by 172
Metadata
- Authors
- Yang, X., Chen, Z., Elvin, C. S. M., Janice, L. H. Y., Ng, S. H., Teo, J. T., & Wu, R.
- Venue
- IEEE Sensors Journal
- Published
- 2015-02
- Volume
- 15
- Issue
- 2
- Pages
- 757-761
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2332409034
- Cited by
- 142
- References
- 1
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Textile Fiber Optic Microbend Sensor Used for Heartbeat and Respiration Monitoring. https://app.cochat.ai/papers/10.1109/jsen.2014.2353640
- The paper
- Yang, X., Chen, Z., Elvin, C. S. M., Janice, L. H. Y., Ng, S. H., Teo, J. T., & Wu, R. (2015). Textile Fiber Optic Microbend Sensor Used for Heartbeat and Respiration Monitoring. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2014.2353640
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.