Cited by 172Advanced Fiber Optic SensorsAdvanced Sensor and Energy Harvesting MaterialsNon-Invasive Vital Sign Monitoring

Medical Smart Textiles Based on Fiber Optic Technology: An Overview

Open access
Massaroni, Carlo, Saccomandi, Paola, Schena, Emiliano·2015·Journal of Functional Biomaterials

Abstract

The growing interest in the development of smart textiles for medical applications is driven by the aim to increase the mobility of patients who need a continuous monitoring of such physiological parameters. At the same time, the use of fiber optic sensors (FOSs) is gaining large acceptance as an alternative to traditional electrical and mechanical sensors for the monitoring of thermal and mechanical parameters. The potential impact of FOSs is related to their good metrological properties, their small size and their flexibility, as well as to their immunity from electromagnetic field. Their main advantage is the possibility to use textile based on fiber optic in a magnetic resonance imaging environment, where standard electronic sensors cannot be employed. This last feature makes FOSs suitable for monitoring biological parameters (e.g., respiratory and heartbeat monitoring) during magnetic resonance procedures. Research interest in combining FOSs and textiles into a single structure to develop wearable sensors is rapidly growing. In this review we provide an overview of the state-of-the-art of textiles, which use FOSs for monitoring of mechanical parameters of physiological interest. In particular we briefly describe the working principle of FOSs employed in this field and their relevant advantages and disadvantages. Also reviewed are their applications for the monitoring of mechanical parameters of physiological interest.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/jfb6020204

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Lightweight wireless pulse oximeters that detect oxygen levels in the blood by analysing real-time patient data are commonly used with COPD.

    “Lightweight wireless pulse oximeters that detect oxygen levels in the blood by analysing real-time patient data are commonly used with COPD [8,9].”
  • Many wearable sensors, such as headbands and textile sensors, are effective in the short-term for activity tracking inside a controlled environment, but are inaccurate in the long-term.

    “Many wearable sensors, such as headbands and textile sensors, are effective in the short-term for activity tracking inside a controlled environment, but are inaccurate in the long-term [8].”
  • The most flexible optical fiber variants can monitor the joints of the human body.

    “The most flexible variants are also capable of monitoring the joints of the human body [201,202].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [201]

  • Optical fibers can monitor human vital signs such as respiration, cardiac activity, blood pressure and flow, oxygen saturation, shear stress, mobility, gait, temperature, and electrolyte balance.

    “Optical fibers can function as inconspicuous flexible systems monitoring human vital signs such as respiration, cardiac activity, blood pressure and flow, oxygen saturation, shear stress, mobility, gait, temperature, and electrolyte balance.”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [201]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 74 · Cited by 172

Research works printed but not linked: 2

  1. [14]Udd E. Fiber Optic Sensors 1st ed. John Wiley & Sons, Inc. Hoboken, New Jersey 2006
  2. [69]Alemdar K. Likoglu S. Fidanboylu K. Toker O. A novel periodic macrobending hetero-core fiber optic sensor embedded in textiles Proceedings of the SPIE 9062, Smart Sensor Phenomena, Technology, Networks, and Systems Integration San Diego, CA, USA 8 March 2014

Authors
Massaroni, C., Saccomandi, P., & Schena, E.
Affiliations
Università Campus Bio-Medico (IT)
Corresponding author
Schena, Emiliano
Venue
Journal of Functional Biomaterials
Publisher
MDPI AG
Published
2015-04-13
Volume
6
Issue
2
Pages
204-221
ISSN
2079-4983 (ISSN-L)
OpenAlex
W2002605163
Cited by
172
References
74
Citations by year
2026: 8 · 2025: 11 · 2024: 15 · 2023: 15 · 2022: 14 · 2021: 21 · 2020: 11 · 2019: 25 · 2018: 17 · 2017: 21 · 2016: 11 · 2015: 3
FWCI
1.22
Type
journal article
Language
en
Open access
Locations
  • Journal of Functional Biomaterials (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
fiber optic sensors, wearable sensors, physiological monitoring, magnetic resonance imaging, respiratory monitoring, heart rate monitoring, electromagnetic interference immunity, textile sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review