The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In-Ear EEG From Viscoelastic Generic Earpieces: Robust and Unobtrusive 24/7 Monitoring
Abstract
We introduce a novel in-ear sensor which satisfies key design requirements for wearable electroencephalography (EEG)-it is discreet, unobtrusive, and capable of capturing high-quality brain activity from the ear canal. Unlike our initial designs, which utilize custom earpieces and require a costly and time-consuming manufacturing process, we here introduce the generic earpieces to make ear-EEG suitable for immediate and widespread use. Our approach represents a departure from silicone earmoulds to provide a sensor based on a viscoelastic substrate and conductive cloth electrodes, both of which are shown to possess a number of desirable mechanical and electrical properties. Owing to its viscoelastic nature, such an earpiece exhibits good conformance to the shape of the ear canal, thus providing stable electrode-skin interface, while cloth electrodes require only saline solution to establish low impedance contact. The analysis highlights the distinguishing advantages compared with the current state-of-the-art in ear-EEG. We demonstrate that such a device can be readily used for the measurement of various EEG responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080
Cited by
Phan, H., Andreotti, F., Cooray, N., Chen, O. Y., & De Vos, M. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896659 · Cited by 623
Increasing trend of wearables and multimodal interface for human activity monitoring: A review
Kumari, P., Mathew, L., & Syal, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.001 · Cited by 298
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Hearables: Automatic Overnight Sleep Monitoring With Standardized In-Ear EEG Sensor
Nakamura, T., Alqurashi, Y. D., Morrell, M. J., & Mandic, D. P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2911423 · Cited by 147
Self-citationSun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112
Metadata
- Authors
- Goverdovsky, V., Looney, D., Kidmose, P., & Mandic, D. P.
- Venue
- IEEE Sensors Journal
- Published
- 2016-01
- Volume
- 16
- Issue
- 1
- Pages
- 271-277
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2218268979
- Cited by
- 192
- References
- 1
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-Ear EEG From Viscoelastic Generic Earpieces: Robust and Unobtrusive 24/7 Monitoring. https://app.cochat.ai/papers/10.1109/jsen.2015.2471183
- The paper
- Goverdovsky, V., Looney, D., Kidmose, P., & Mandic, D. P. (2016). In-Ear EEG From Viscoelastic Generic Earpieces: Robust and Unobtrusive 24/7 Monitoring. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2015.2471183
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.