CoChat

Effective Heart Sound Segmentation and Murmur Classification Using Empirical Wavelet Transform and Instantaneous Phase for Electronic Stethoscope

Nivitha Varghees, V., Ramachandran, K. I. · 2017 · IEEE Sensors Journal
Cited by 159

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Accurate measurement of heart sound and murmur parameters is of great importance in the automated analysis of phonocardiogram (PCG) signals. In this paper, we propose a novel unified PCG signal delineation and murmur classification method without the use of reference signal for automatic detection and classification of heart sounds and murmurs. The major components of the proposed method are the empirical wavelet transform-based PCG signal decomposition for discriminating heart sounds from heart murmurs and suppressing background noises, the Shannon entropy envelope extraction, the instantaneous phase-based boundary determination, heart sound and murmur parameter extraction, the systole/diastole discrimination and the decision rules-based murmur classification. The accuracy and robustness of the proposed method is evaluated using a wide variety of normal and abnormal PCG signals taken from the standard PCG databases, including PASCAL heart sounds challenge database, PhysioNet/CinC challenge heart sound database, and real-time PCG signals. Evaluation results show that the proposed method achieves an average sensitivity (Se) of 94.38%, positive predictivity (Pp) of 97.25%, and overall accuracy (OA) of 91.92% for heart sound segmentation and Se of 97.58%, Pp of 96.46%, and OA of 94.21% in detecting the presence of heart murmurs for SNR of 10 dB. The method yields an average classification accuracy of 95.5% for the PCG signals with SNR of 20 dB. Results show that the proposed method outperforms other existing heart sound segmentation and murmur classification methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2017.2694970

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Nivitha Varghees, V., & Ramachandran, K. I.
Venue
IEEE Sensors Journal
Published
2017-06-15
Volume
17
Issue
12
Pages
3861-3872
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2607377556
Cited by
159
References
2
FWCI
11.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effective Heart Sound Segmentation and Murmur Classification Using Empirical Wavelet Transform and Instantaneous Phase for Electronic Stethoscope. https://app.cochat.ai/papers/10.1109/jsen.2017.2694970
The paper
Nivitha Varghees, V., & Ramachandran, K. I. (2017). Effective Heart Sound Segmentation and Murmur Classification Using Empirical Wavelet Transform and Instantaneous Phase for Electronic Stethoscope. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2017.2694970

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.