Leveraging Innate Piezoelectricity of Ultra-Smooth Silk Thin Films for Flexible and Wearable Sensor Applications
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this paper, the innate peizoelectricity of silk is utilized to demonstrate an optimized silk thin film-based pressure sensor. Furthermore, a novel approach to pattern silk films is proposed, which could potentially lead to the development of a variety of miniaturized, flexible, and wearable sensors. The key in this endeavor is to achieve a uniform thin film of silk. The preparation methodology was optimized to achieve an ultra-smooth, reproducible thin film. The surface quality of the optimized thin film was analyzed using atomic force microscopy and the RMS roughness was found to be 2.43 nm. The piezo-response of the silk film was measured using Piezo force microscopy and the average d33value of the silk piezoelectric thin film was estimated at 56.7 pm/V. A pressure sensor using silk piezoelectric thin film was developed with a simple process flow. This process is devoid of any silk patterning steps. Keeping in view the potentiality of piezoelectric silk films in MEMS, a novel lithography-based technique was developed to pattern the silk films. This patterning technique can easily be integrated with any standard MEMS/Post CMOS process flow, thus opening up a new avenue in developing a variety of sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Min, B.-M., Lee, G., Kim, S. H., Nam, Y. S., Lee, T. S., & Park, W. H. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.045 · Cited by 1,151
Qi, Y., Kim, J., Nguyen, T. D., Lisko, B., Purohit, P. K., & McAlpine, M. C. (2011) · Nano Letters · doi:10.1021/nl104412b · Cited by 516
Cited by
Piezoelectric Biomaterials for Sensors and Actuators
Chorsi, M. T., Curry, E. J., Chorsi, H. T., Das, R., Baroody, J., Purohit, P. K., Ilies, H., & Nguyen, T. D. (2019) · Advanced Materials · doi:10.1002/adma.201802084 · Cited by 865
Reizabal, A., Costa, C. M., Pérez‐Álvarez, L., Vilas‐Vilela, J. L., & Lanceros‐Méndez, S. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202210764 · Cited by 285
Recent progress in silk fibroin-based flexible electronics
Wen, D.-L., Sun, D.-H., Huang, P., Huang, W., Su, M., Wang, Y., Han, M.-D., Kim, B., Brugger, J., Zhang, H.-X., et al. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00261-2 · Cited by 274
Wearable Sensors for Monitoring Human Motion: A Review on Mechanisms, Materials, and Challenges
Homayounfar, S. Z., & Andrew, T. L. (2020) · SLAS TECHNOLOGY · doi:10.1177/2472630319891128 · Cited by 227
“Joseph et al.(76) have reported a pressure sensor by using a silk piezoelectric thin film as the active material.”
BackgroundBiodegradable Piezoelectric Polymers: Recent Advancements in Materials and Applications
Ali, M., Bathaei, M. J., Istif, E., Karimi, S. N. H., & Beker, L. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202300318 · Cited by 211
Metadata
- Authors
- Joseph, J., Singh, S. G., & Vanjari, S. R. K.
- Venue
- IEEE Sensors Journal
- Published
- 2017-12-15
- Volume
- 17
- Issue
- 24
- Pages
- 8306-8313
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2765404759
- Cited by
- 42
- References
- 2
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.