The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Optimal Foot Location for Placing Wearable IMU Sensors and Automatic Feature Extraction for Gait Analysis
Abstract
Our aim is to maximize the interpretable information for gait analysis. To achieve this, it is important to find the optimal sensor placement and the parameters that influence the extraction of automatic gait features. We investigated the effect of different anatomical foot locations on inertial measurement unit (IMU) sensor output. We designed and developed an android app to collect real-time synchronous sensor output. We selected a set of five anatomical foot locations covering most of the foot regions to place wearable IMU sensors for data collection. Each participant performed a trial in a straight corridor comprising 25 strides of normal walking, a turn-around, and another 25 strides. We proposed an automatic gait features extraction method to analyze the data for stride number, distance, speed, length and period of stride, stance, and swing phases during walking. The highest accuracy for detecting stride number was in location 1 (first cuneiform) followed by location 5 (Achilles Tendon) and 4 (Talus). Location 1 was the closest to correlate estimate to the measured distance travelled. The accuracy of detecting number of strides on average is 95.47% from accelerometer data and 93.60% from gyroscope data and closest to the 60:40% split for average stance and swing for 15 subjects. To validate our results, we conducted trials using the Qualisys motion capture instrument and from our sensors concurrently. The average accuracy of the result is 97.77% with 95% confidence interval 0.767 for estimated and 99.01% with 95% confidence interval 0.266 for period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Best Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Independent predictors of cognitive decline in healthy elderly persons
Marquis, S., Moore, M. M., Howieson, D. B., Sexton, G., Payami, H., Kaye, J. A., & Camicioli, R. (2002) · Archives of Neurology · doi:10.1001/archneur.59.4.601 · Cited by 344 · cited 1×
“It is also a predictor of functional and cognitive decline [9], [10].”
BackgroundUsing gravity to estimate accelerometer orientation
Mizell, D. (2004) · Seventh IEEE International Symposium on Wearable Computers, 2003. Proceedings. · doi:10.1109/iswc.2003.1241424 · Cited by 212
Numerical double integration of acceleration measurements in noise
Thong, Y. K., Woolfson, M. S., Crowe, J. A., Hayes-Gill, B. R., & Jones, D. A. (2004) · Measurement · doi:10.1016/j.measurement.2004.04.005 · Cited by 206
Foster, R. C., Lanningham-Foster, L. M., Manohar, C., McCrady, S. K., Nysse, L. J., Kaufman, K. R., Padgett, D. J., & Levine, J. A. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2005.07.006 · Cited by 187
A wearable system for gait training in subjects with Parkinson's disease
Casamassima, F., Ferrari, A., Milosevic, B., Ginis, P., Farella, E., & Rocchi, L. (2014) · Sensors · doi:10.3390/s140406229 · Cited by 131
Cited by
A survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
Self-citationWearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
“[47] suggests that the optimal location for IMU placement on the foot is the medial arch followed by the Achilles tendon.”
BackgroundSigcha, L., Costa, N., Pavón, I., Costa, S., Arezes, P., López, J. M., & De Arcas, G. (2020) · Sensors · doi:10.3390/s20071895 · Cited by 126
Optimization of IMU sensor placement for the measurement of lower limb joint kinematics
Niswander, W., Wang, W., & Kontson, K. (2020) · Sensors · doi:10.3390/s20215993 · Cited by 116
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
BackgroundHsu, W.-C., Sugiarto, T., Lin, Y.-J., Yang, F.-C., Lin, Z.-Y., Sun, C.-T., Hsu, C.-L., & Chou, K.-N. (2018) · Sensors · doi:10.3390/s18103397 · Cited by 101
Metadata
- Authors
- Anwary, A. R., Yu, H., & Vassallo, M.
- Venue
- IEEE Sensors Journal
- Published
- 2018-03-15
- Volume
- 18
- Issue
- 6
- Pages
- 2555-2567
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2782354506
- Cited by
- 175
- References
- 7
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.