CoChat

Refractive Index-Based Blood Components Sensing in Terahertz Spectrum

Ahmed, Kawsar, Ahmed, Fahad, Roy, Subrata, Paul, Bikash Kumar, Aktar, Mst. Nargis, Vigneswaran, Dhasarathan, Islam, Md. Saiful · 2019 · IEEE Sensors Journal
Cited by 224

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In this paper, a novel partial type-b crystalline core with more compact cladding in hexagonal packing photonic crystal fiber (CC-PCF)-based optical sensor has been proposed for sensing different blood components. This fiber has investigated in terahertz (THz) region from 1.5 to 3.50 THz, intending to superior relative sensitivity with low confinement loss (CL). Circular air holes have been employed in the formation of the partial type-b crystalline core in a symmetric manner. A significant relative sensitivity response of 80.93%, 80.56%, 80.13%, 79.91%, and 79.39% are achieved for the targeted analytes such as RBCs, hemoglobin, WBCs, plasma, and water at frequencyf = 1.5 THz. In X-polarization mode, a negligible CL of 1.23 × 10-11dB/m, 8.63 × 10-12dB/m, 4.93 × 10-12dB/m, 2.93 × 10-12dB/m, and 1.13 × 10-12dB/m are also gained, respectively, for same analytes and at same THz frequency. Moreover, effective area (Aeff), V-Parameter (Veff), dispersion (β2), spot size (Weff), and beam divergence (θ) have been determined over the investigated region. The improved outcomes are anticipated that the proposed CC-PCF sensor will be opened a new epoch in biomedical sensing purposes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2019.2895166

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Ahmed, K., Ahmed, F., Roy, S., Paul, B. K., Aktar, M. N., Vigneswaran, D., & Islam, M. S.
Venue
IEEE Sensors Journal
Published
2019-05-01
Volume
19
Issue
9
Pages
3368-3375
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2912352109
Cited by
224
References
4
FWCI
8.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.