Hydrogel Based-Electrochemical Gas Sensor for Explosive Material Detection
Abstract
In Thailand, most of the bomb devices produced by the terrorists use trinitrotoluene (TNT) as the main explosive material. Detecting TNT and preventing detonation could save many civilians. Due to its low vapor pressure, TNT requires an extremely high sensitivity method for detection. In this paper, we propose an application of the polyacrylamide gel as an electrochemical gas sensor for explosive material detection. Cyclic voltammetry signals were collected from samples, including TNT, pentaerythritol tetranitrate (PETN), and non-explosive vapors. It was found that a time-derivative calculation of the signal was unique to each chemical, rather than the signal itself, demonstrating utility for the detection of explosive material. This approach for making a gel-based sensor and the data analysis looks promising and requires further validation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Different gas phase structures interacted differently with the acrylamide side chain, resulting in increased or decreased electron rates in the Fe2+/Fe3+ redox reaction.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Puttasakul et al. [249]
In the citing paper
“The analysis revealed that the type and concentration of molecules adsorbed on the hydrogel surface can change the rate of electron transfer in Fe2+/Fe3+ redox.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Puttasakul et al. [249]
In the citing paper
“However, the hydrogel sensor has not undergone any functionalization, and it is easy to lose water and become dry during the actual detection process, and also cannot work properly at higher temperatures for a long time, which needs further improvement and optimization.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Puttasakul et al. [249]
In the citing paper
“Each compound has a different rate of current change, and different samples can be identified by the current change.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Puttasakul et al. [249]
Citations
Cites
Dionne, B. C., Rounbehler, D. P., Achter, E. K., Hobbs, J. R., & Fine, D. H. (1986) · Journal of Energetic Materials · doi:10.1080/07370658608011353 · Cited by 197
Jo, H., Sim, M., Kim, S., Yang, S., Yoo, Y., Park, J.-H., Yoon, T. H., Kim, M.-G., & Lee, J. Y. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.035 · Cited by 188
Porphyrin Functionalized Graphene for Sensitive Electrochemical Detection of Ultratrace Explosives
Guo, C. X., Lei, Y., & Li, C. M. (2011) · Electroanalysis · doi:10.1002/elan.201000522 · Cited by 159
A Hybrid Nanosensor for TNT Vapor Detection
Aguilar, A. D., Forzani, E., Leright, M., Tsow, F., Cagan, A. A., Iglesias, R. A., Nagahara, L. A., Amlani, I., Tsui, R. K., & Tao, N. J. (2009) · Nano Letters · doi:10.1021/nl902382s · Cited by 154
Zhang, D., Jiang, J., Chen, J., Zhang, Q. Y., Lu, Y., Yao, Y., Li, S., Liu, G. L., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.004 · Cited by 143
Tian, X., Peng, H., Li, Y., Yang, C., Zhou, Z., & Wang, Y. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.12.079 · Cited by 134
Acceleration of chemo-sensory information processing using transient features☆
Muezzinoglu, M. K., Vergara, A., Huerta, R., Rulkov, N. F., Rabinovich, M. I., Selverston, A. I., & Abarbanel, H. D. I. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.10.065 · Cited by 111
Aparna, R. S., Devi, J. S. A., Sachidanandan, P., & George, S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.097 · Cited by 108
Naal, Z., Park, J.-H., Bernhard, S., Shapleigh, J. P., Batt, C. A., & Abruña, H. D. (2001) · Analytical Chemistry · doi:10.1021/ac010596o · Cited by 103
Transient response analysis of an electronic nose using multi-exponential models
Gutiérrez‐Osuna, R., Nagle, H. T., & Schiffman, S. S. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00290-7 · Cited by 102
Guo, Z., Florea, A., Cristea, C., Bessueille, F., Vocanson, F., Goutaland, F., Zhang, A., Săndulescu, R., Lagarde, F., & Jaffrezic-Renault, N. J. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.06.137 · Cited by 97
Shahdost-fard, F., & Roushani, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.048 · Cited by 97
Analysis of the conductance transient in thick-film tin oxide gas sensors
Vilanova, X., Llobet, E., Alcubilla, R., Sueiras, J. E., & Correig, X. (1996) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(96)80063-3 · Cited by 71
Yu, H. A., Lee, J., Lewis, S. W., & Silvester, D. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00679 · Cited by 58
Visual detection of 2,4,6-trinitrotolune by molecularly imprinted colloidal array photonic crystal
Lu, W., Asher, S. A., Meng, Z., Yan, Z., Xue, M., Qiu, L., & Yi, D. H. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.05.022 · Cited by 55
Zang, F., Gerasopoulos, K., Fan, X. Z., Brown, A., Culver, J. N., & Reza Ghodssi, A. (2014) · Chemical Communications · doi:10.1039/c4cc06735e · Cited by 51
Ghorpade, T. K., Palai, A. K., Rath, S. K., Sharma, S. K., Sudarshan, K., Pujari, P. K., Patri, M., & Mishra, S. P. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.059 · Cited by 25
Warzecha, M., Calvo‐Castro, J., Kennedy, A. R., Macpherson, A. N., Shankland, K., Shankland, K., McLean, A. J., & McHugh, C. J. (2014) · Chemical Communications · doi:10.1039/c4cc08468c · Cited by 23
Weiss, J. M., McKay, A. J., DeRito, C. M., Watanabe, C., Thorn, K. A., & Madsen, E. L. (2004) · Environmental Science & Technology · doi:10.1021/es034911v · Cited by 22
SPR Enhanced molecular imprinted sol–gel film: A promising tool for gas-phase TNT detection
Giustina, G. D., Sonato, A., Gazzola, E., Ruffato, G., Brusa, S., & Romanato, F. (2015) · Materials Letters · doi:10.1016/j.matlet.2015.09.114 · Cited by 21
Moreno‐Tortolero, R. O., Penott-Chang, E. K., de Gáscue, B. R., & Müller, A. J. (2017) · European Polymer Journal · doi:10.1016/j.eurpolymj.2017.01.005 · Cited by 20
Khanniche, S., Mathieu, D., Pereira, F., Frenois, C., Colin, D., Barthet, C., & Hairault, L. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.03.137 · Cited by 16
Trace Detection of 2, 4, 6-Trinitrotoluene Using Electrochemical Gas Sensor
Sekhar, P. K., & Brosha, E. L. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2364519 · Cited by 11
Dynamic Calibration of Electrochemical Sensor for Accelerated Analyte Quantification
Yang, F., Geng, Z., Koneru, A., Zhi, M., Li, H., & Wu, N. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2231066 · Cited by 5
Molecularly Imprinted Polymer for explosive detection
Tancharoen, C., Sukjee, W., Sangma, C., & Wangchareansak, T. (2015) · Asian Conference on Defence Technology · doi:10.1109/acdt.2015.7111605 · Cited by 4
Self-citation
Cited by
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
Metadata
- Authors
- Puttasakul, T., Pintavirooj, C., Sangma, C., & Sukjee, W.
- Affiliations
- King Mongkut's Institute of Technology Ladkrabang (TH)
- Kasetsart University (TH)
- Venue
- IEEE Sensors Journal
- Published
- 2019-10-01
- Volume
- 19
- Issue
- 19
- Pages
- 8556-8562
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2952701974
- Cited by
- 25
- References
- 26
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 4 · 2023: 4 · 2022: 6 · 2021: 3 · 2020: 3
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- Rangsit University
- Office of the Higher Education Commission, Military Research and Development
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- electrochemical gas sensors, hydrogels, polyacrylamide hydrogel, explosives detection, TNT, PETN, cyclic voltammetry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.