The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Comparative Analyses of Circular Gate TFET and Heterojunction TFET for Dielectric-Modulated Label-Free Biosensing
Abstract
This paper compares circular gate (CG) tunnel field effect transistor (TFET) and uniform gate Heterojunction (HJ) TFET as label-free biosensors based on dielectric modulation. Neutral and charged biomolecules with different values of dielectric constant are considered. Sensitivities of partially filled nanogaps arising out of steric hindrance in both the biosensors for concave, convex, increasing and decreasing step profiles of biomolecules are compared. The effect of probe position on sensitivities of the two biosensors is reported for various cases. A status map is presented, plotting the sensitivities of some of the most significant works in applications of FET as label-free biosensors along with sensitivities of the proposed devices. CG TFET exhibits higher sensitivity than HJ TFET due to its non-uniform gate architecture. The sensitivities of the TFETs are highly dependent on the position of biomolecules (steric hindrance and probe position) with respect to the tunnel junction. A maximum sensitivity of 1.31 × 108(3.382 × 106) is achieved for fully filled nanogap in CG TFET (HJ TFET) for dielectric constant 12.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Narang, R., Reddy, K. V. S., Saxena, M., Gupta, R. S., & Gupta, M. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2208115 · Cited by 308 · cited 6×
“cules are considered in accordance with the values reported for DNA [11], [20]–[22], [35] which is negatively charged.”
BackgroundMethodResultInfluentialComparative analysis of dielectric- modulated FET and TFET-based biosensor
Narang, R., Saxena, M., & Gupta, M. (2015) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2015.2396899 · Cited by 296
Performance Assessment of A Novel Vertical Dielectrically Modulated TFET-Based Biosensor
Verma, M., Tirkey, S., Yadav, S., Sharma, D., & Yadav, D. S. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2732820 · Cited by 276
Pratap, Y., Kumar, M., Kabra, S., Haldar, S., Gupta, R. S., & Gupta, M. (2018) · Journal of Computational Electronics · doi:10.1007/s10825-017-1041-4 · Cited by 99
Cited by
Wangkheirakpam, V. D., Bhowmick, B., & Pukhrambam, P. D. (2020) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2020.2969206 · Cited by 199
“The expressions of Ceff for different fill factors of the cavities are listed in Table I [24].”
BackgroundSelf-citation
Metadata
- Authors
- Goswami, R., & Bhowmick, B.
- Venue
- IEEE Sensors Journal
- Published
- 2019-11-01
- Volume
- 19
- Issue
- 21
- Pages
- 9600-9609
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2962435255
- Cited by
- 248
- References
- 4
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative Analyses of Circular Gate TFET and Heterojunction TFET for Dielectric-Modulated Label-Free Biosensing. https://app.cochat.ai/papers/10.1109/jsen.2019.2928182
- The paper
- Goswami, R., & Bhowmick, B. (2019). Comparative Analyses of Circular Gate TFET and Heterojunction TFET for Dielectric-Modulated Label-Free Biosensing. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2019.2928182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.