Cited by 128Advanced Fiber Optic SensorsNon-Invasive Vital Sign MonitoringAdvanced Sensor and Energy Harvesting Materials

Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review

Massaroni, Carlo, Zaltieri, Martina, Lo Presti, Daniela, Nicolo, Andrea, Tosi, Daniele, Schena, Emiliano·2021·IEEE Sensors Journal

Abstract

Systems for cardiorespiratory monitoring hold tremendous promise for many applications in clinical settings, harsh environments, sports science and telemonitoring. However, the translation in the real world is challenging because it is difficult to develop unobtrusive and comfortable systems with high metrological performance. Recent advances in fiber optic technology in the field of sensing and their application to instrument wearable systems can tackle the main issues in this field. In this work, we focused on the recent advances in cardiorespiratory monitoring of fiber Bragg grating (FBGs) sensors which are one of the most popular sensors based on fiber optic technology. We provide an overview of the FBGs working principle and performance. We also describe the most popular and promising configurations based on FBGs used for cardiorespiratory monitoring.

Integrity signals

Registry

Crossref · 10.1109/jsen.2020.2988692

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Commercial T-shirts equipped with a single fiber optic housing two FBGs glued on the textile with silicone rubber can monitor RR and HR waves.

    “Furthermore, the commercial T-shirts equipped with a single fiber optic housing two FBGs for RR and HR waves’ monitoring, where the FBGs were glued on the textile with silicone rubber were reported [249,250,251].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [251]

The citation lists haven’t been fetched yet

References 103 · Cited by 128

Authors
Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E.
Affiliations
  • Università Campus Bio-Medico (IT)
  • Nazarbayev University (KZ)
Venue
IEEE Sensors Journal
Published
2021-07-01
Volume
21
Issue
13
Pages
14069-14080
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W3019149371
Cited by
128
References
103
Citations by year
2026: 12 · 2025: 20 · 2024: 27 · 2023: 23 · 2022: 21 · 2021: 15 · 2020: 10
FWCI
5.92
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Sensors Journal (publishedVersion)
  • Nazarbayev University Repository (Nazarbayev University) (submittedVersion)
Funders
  • H2020 (H2020/ICT European project CONBOTS (?CONnected t)
  • Nazarbayev University (under grants SMARTER (code: 091019CRP2117) and EPI)
  • Istituto Nazionale per lAssicurazione Contro Gli Infortuni sul Lavoro (2018 BRIC INAIL ID10/2018 SENSE-RISC project)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
fiber Bragg grating sensors, cardiorespiratory monitoring, wearable sensors, fiber optic sensing, remote patient monitoring, non-intrusive monitoring, sensor configuration, metrological performance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›