Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review
Abstract
Systems for cardiorespiratory monitoring hold tremendous promise for many applications in clinical settings, harsh environments, sports science and telemonitoring. However, the translation in the real world is challenging because it is difficult to develop unobtrusive and comfortable systems with high metrological performance. Recent advances in fiber optic technology in the field of sensing and their application to instrument wearable systems can tackle the main issues in this field. In this work, we focused on the recent advances in cardiorespiratory monitoring of fiber Bragg grating (FBGs) sensors which are one of the most popular sensors based on fiber optic technology. We provide an overview of the FBGs working principle and performance. We also describe the most popular and promising configurations based on FBGs used for cardiorespiratory monitoring.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Commercial T-shirts equipped with a single fiber optic housing two FBGs glued on the textile with silicone rubber can monitor RR and HR waves.
“Furthermore, the commercial T-shirts equipped with a single fiber optic housing two FBGs for RR and HR waves’ monitoring, where the FBGs were glued on the textile with silicone rubber were reported [249,250,251].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [251]
The citation lists haven’t been fetched yet
References 103 · Cited by 128
- Authors
- Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E.
- Affiliations
- Università Campus Bio-Medico (IT)
- Nazarbayev University (KZ)
- Venue
- IEEE Sensors Journal
- Published
- 2021-07-01
- Volume
- 21
- Issue
- 13
- Pages
- 14069-14080
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W3019149371
- Cited by
- 128
- References
- 103
- Citations by year
- 2026: 12 · 2025: 20 · 2024: 27 · 2023: 23 · 2022: 21 · 2021: 15 · 2020: 10
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Nazarbayev University Repository (Nazarbayev University) (submittedVersion)
- Funders
- H2020 (H2020/ICT European project CONBOTS (?CONnected t)
- Nazarbayev University (under grants SMARTER (code: 091019CRP2117) and EPI)
- Istituto Nazionale per lAssicurazione Contro Gli Infortuni sul Lavoro (2018 BRIC INAIL ID10/2018 SENSE-RISC project)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- fiber Bragg grating sensors, cardiorespiratory monitoring, wearable sensors, fiber optic sensing, remote patient monitoring, non-intrusive monitoring, sensor configuration, metrological performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review